TOA Electronics SLDVT-35, SLDVT-40 manual See Maintenance Schedule

Page 5

2.During the first initial burns of these appli- ances, there will be some odor emitted (see Burn-In Period on Page 3 ).

3.Keep the lower control compartment clean by vacuuming or brushing at least twice a year. More frequent cleaning may be required due to excessive lint from carpet- ing, bedding materials, pet hair, etc. It is very important that control compartments, burners, circulating air passageways and air venturi on the appliance are NOT obstructed in any way.

4.Always turn off gas to the pilot (millivolt appliances) and let the appliance cool down before cleaning. Before re-lighting, refer to the lighting instructions in this manual. Lighting instructions may also be found on the pull out lighting instruction labels attached to the gas control valve.

5.Always keep the appliance area clear and free from combustible materials, gasoline and other flammable liquids.

6.Remember,Millivoltapplianceshaveacontinu- ousburningpilotflame. Exercisecautionwhen using products with combustible vapors.

MAINTENANCE

(See Maintenance Schedule, Page 22)

Refertothemaintenancescheduleformaintenance tasks, procedures, periodicity and by whom they should be performed. Always verify proper opera- tion of the appliance after servicing.

WARNING: Turn off gas and elec- trical power before servicing the appliance.

CAUTION: Wear gloves and safety Glasses for protection while doing required maintenance.

IMPORTANT: Always verify proper operation after servicing.

Before re-lighting the fireplace, refer to the lighting instructions in this manual. Instruc- tions are also found on pull-out panels located below the glass door in the control compartment.

Inspect Venting System

The appliance and venting system should be thoroughly inspected before initial use and at least annually by a qualified service techni- cian (inspection should include ensuring that exhaust or intake passages are unobstructed and vent components are properly assembled and not damaged).

If the venting system is disassembled for any reason, a qualified service technician should follow vent installation instructions for proper reassembly and proper sealing of the venting system components. However, more frequent periodic inspections and cleanings should be performed by the homeowner.

Cleaning Glass

(see Front Glass Enclosure Panel, Removal and Installation on Page 6 )

Note: Clean glass after first two weeks of opera- tion (after Burn-In period is over) and then only when necessary and when the fireplace is cool. Wipe surface with clean, dampened, soft cloth. Follow with dry, soft towel as desired. Take care not to scratch the glass surface.

The viewing glass should be cleaned periodi- cally to remove any build-up caused from the following:

IMPORTANT: Do not use abrasive cleaners on glass. Never clean the glass when it is hot.

During start-up, it is normal for condensa- tion to form on the inside of the glass (this condensation and fog will usually disappear in a few minutes). The moisture can cause lint, dust and other airborne particles to cling to the glass surface.

Initial curing of the high temperature paint and burning off of lubricants used in the manufacturing process may result in a film on the glass.

A white coating may form on the glass as a result of impurities and minerals in the fuel.

It is recommended that the glass be cleaned two or three times during each heating season, depending on the circumstances present. The following cleaning solutions are approved for use to clean glass:

Non-ammonia based household cleaner

50%-50% mix of white vinegar & water

Gas fireplace/stove glass cleaner

Inspect Glass Gasket - Visually inspect the gasket on the backside of the glass enclosure panels. The gasket surface must be clean, free of irregularities and seated firmly.

Clean Logs And Burner

Carefully remove the logs (use care when han- dling the fiber logs, as they become quite fragile after curing). Vacuum out any foreign matter (lint, carbon, etc). on the burner. Ensure the burner ports are “open.” Remove any carbon deposits from the under side of the logs using

avacuum cleaner, or a soft bristled brush (i.e. paint brush). Note: Improper positioning of logs can create carbon build-up and will alter the performance of the appliance.

Replacing Logs -

If the logs become damaged by accident or im- proper handling and need replacement, use only the proper replacement logs from manufacturer (see Pages 26 & 27 for ordering information).

Re-Install Embers and Logs - Carefully follow placement instructions on Pages 7 to 9 ). All logs should fit onto corresponding pins and/or log stoppers. This will ensure a proper flame and safe combustion.

Inspect Wiring

Refer to wiring diagrams on Page 12.

WARNING: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous opera- tion. Verify proper operation after servicing.

Inspect and clean all wire connections. Ensure that there is no melting or damage. Inspection should include:

Terminals at the Valve

OFF/ON Switch

(Optional Control Switch) Wall Thermostat, Remote Control or Remote Wall Switch Kit

Inspect Burner Flame Appearance

Ensure that the burner flame appearance resembles the flame shown in Figures 9 & 10 and as described in Flame Appearance and Sooting on Page 10. The Homeowner must contact a qualified service technician at once if any abnormal condition is observed.

Small Area Paint Touch-up

The finish of the appliance is a high-qual- ity powdercoat. Only use factory supplied powdercoat paint kit for touch-ups. Paint is available at your local authorized Lennox Hearth Products dealer. Never attempt to paint a hot fireplace.

Do not attempt to repaint the appliance until the finish is completely cured (see Burn-In Period on Page 3 ). If the surface later becomes stained or marred, it may be lightly sanded and touched up with spray paint.

Image 5
Contents Do not light any appliance Gaz, appelez le service dos incendiesMent où vous vous trouvez Du fournisseurTable of Contents Reinstalling Control Compartment Door Gas Controls/Control Compartment AccessBurn-in Period Operation and care of your applianceElectronic Appliances Variable Flame Height AdjustmentInch Pipe Nipple Gas Flex Line Valve Piezo SIT MillivoltImportant Always verify proper operation after servicing MaintenanceSee Maintenance Schedule, See Figure Front Glass Enclosure Panel, Removal and InstallationRemoving Glass Enclosure Panels Placement of Logs Install Volcanic STONE, Glowing Embers and LogsFirebox Accessories / Parts Volcanic StoneCatalog Number for the entire log set H7244 SLDVT-35 Log PlacementCatalog Number for the entire log set H7245 SLDVT-40 Log PlacementLeft Rear BracketAir Shutter Adjustment Guidelines Burner AdjustmentsBurner Air Shutter Adjustment Procedure Flame Appearance and sootingWarranty Burner Air Shutter AdjustmentReplacement parts Product reference informationWiring Diagrams Accessory Components Product Reference Information Polished Brass & Brushed Stainless 2-Piece Door Frame Kits Accessory Components Style View Screen DoorsAccessory Components Lighting Instructions Millivolt GAS Valve For Your Safety Read Before LightingLighting Instructions To Turn OFF GAS to ApplianceInstructions Dallumage Instructions D’ALLUMAGE Vanne GAZ MillivoltTo shut off Lighting Instructions ElectronicWhat to do if YOU Smell GAS Pour Éteindre L’APPAREIL Instructions D’ALLUMAGE ElectronicInstructions D’ALLUMAGE Maintenance Task Accomplishing Person Procedure Maintenance ScheduleManual. Do not touch or attempt to clean glass While hotSymptom Possible Causes Corrective Action TroubleshootingNothing happens when Low voltage/or bad lead Symptom Possible causes Corrective actionCheck wire connection Batteries LowGas Controls Dexen Electronic Gas Controls SIT Millivolt24 P/N 506010-01 REV. N/C 08/2008 Assembly SIT ValveDexen Valve