TOA Electronics P0055-DRG manual Retain These Instructions, Vented GAS Fireplaces

Page 1

HOMEOWNER'S CARE AND OPERATION INSTRUCTIONS

B-VENT

GHC/GRD-5500 SERIES

B-VENTED GAS FIREPLACES

P/N 725,029M REV. C 07/2004

MODELS

Millivolt

Models

GHC-5500N

GRD-5500 SHOWNGHC-5500PGRD-5500N

GRD-5500P

Electronic

Models

GHC-5500NE-2 GHC-5500PE-2 GRD-5500NE-2 GRD-5500PE-2

RETAIN THESE INSTRUCTIONS

FOR FUTURE REFERENCE

WH Report No. J20046562

WARNING:IFTHEINFORMATIONINTHISMANUAL IS NOT FOLLOWED EXACTLY, A FIRE OR EXPLO- SION MAY RESULT CAUSING PROPERTY DAM- AGE, PERSONAL INJURY OR LOSS OF LIFE.

FOR YOUR SAFETY: Do not store or use gasoline or other flammable vapors or liquids in the vicin- ity of this or any other appliance.

FOR YOUR SAFETY: What to do if you smell gas:

DO NOT light any appliance.

DO NOT touch any electrical switches.

DO NOT use any phone in your building.

Immediately call your gas supplier from a

neighbor’s phone.

Follow your gas suppliers instructions.

If your gas supplier cannot be reached, call the fire department.

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

AVERTISSEMENT: ASSUREZ-VOUS DE BIEN SUIVRE LESINSTRUCTIONSDONNÉDANSCETTENOTICEPOUR RÉDUIRE AU MINIMUM LE RISQUE D'INCENDIE OU POUR ÉVITER TOUT DOMMAGE MATÉRIEL, TOUTE BLESSURE OU LA MORT.

POUR VOTRE SÉCURITÉ: Ne pas entreposer ni utiliser d'essence ni d'autre vaperurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil.

POUR VOTRE SÉCURITÉ: Que faire si vous sentez une odeur de gaz:

Ne pas tenter d'allumer d'appareil.

Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones se trouvant dans le batiment où vous vous trouvez.

Evacuez la piéce, le bâtiment ou la zone.

Appeflez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur.

Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le service dos incendies.

L'installation et service doit être exécuté par un qualifié installer, agence de service ou le fournisseur de gaz.

Image 1
Contents Vented GAS Fireplaces Retain These Instructions725,029M REV. C 07/2004 GRD-5500 SHOWNGHC-5500PGRD-5500NCongratulations Table of ContentsControl Compartment Access GRD-5500 Units Gas Controls/Control Compartment AccessControl Compartment Access GHC-5500 Units Operation and Care of Your ApplianceElectronic Appliance Lighting Millivolt Appliance LightingOutside Combustion Air Controls Manual Reset Limit Switch Lintel MaintenanceFirebox Wrapper Limit Switch Screws Burner Adjustments Flame Appearance and SootingMaintenance Task Accomplishing Person Procedure Maintenance ScheduleMaintenance Task Accomplishing Person Millivolt Appliance Checkout Logs and Rockwool Glowing Embers PlacementElectronic Appliance Checkout LOG Placement Replacement Parts WarrantyElectronic System Wiring Without Forced Air Kit Product Reference InformationLighting Instructions Lighting Instructions Millivolt GAS ValveTo Turn OFF GAS to Appliance Instructions Dallumage Instructions D’ALLUMAGE Vanne GAZ MillivoltPour Fermer LE GAZ QUI Alimente L’APPAREIL What to do if YOU Smell GAS Lighting Instructions ElectronicTo Shut OFF Instructions D’ALLUMAGE Electronic Fermez la porte du compartiment de contrôle du basDefective limit switch Lighting instructions Switch wiring On generatorPilot burning, no gas to Wall switch or wires Wall switch onSymptom Possible Causes Corrective Action Troubleshooting the Electronic Ignition SystemStandard Remote Control System Model RCL Accessory ComponentsHorizontal Trim Installation Aluminum-Framed Bi-Fold DoorsGAS CONTROLS- Robertshaw Millivolt Replacement Parts List Millivolt SystemGRD-5500 GHC/GRD-5500Replacement Parts Millivolt GAS CONTROLS- Robertshaw Electronic Replacement Parts List Electronic SystemManufactured by LHP 725,029M REV. C 07/2004 Replacement Parts Electronic