TOA Electronics P0055-DRG Lighting Instructions Millivolt GAS Valve, To Turn OFF GAS to Appliance

Page 10

LIGHTING INSTRUCTIONS – MILLIVOLT GAS VALVE

FOR YOUR SAFETY READ BEFORE LIGHTING

WARNING: IF YOU DO NOT FOLLOW THESE INSTRUCTIONS EXACTLY, A FIRE OR EXPLOSION

MAY RESULT CAUSING PROPERTY DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

A.This appliance has a pilot which must be lighted with a piezo ignitor. When lighting the pilot, follow these instructions exactly.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

Extinguish any open flame.

Open windows.

Do not light any appliance.

Do not touch any electrical switches.

Do not use any phone in your building.

Immediately call your gas supplier from a neighbor’s phone.

If your gas supplier cannot be reached, call the fire depart- ment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it, call a qualified service technician. Force or attempted repair may result in a fire or an explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

LIGHTING INSTRUCTIONS

1.STOP! Read the safety information above on this page.

2.Access the lower control compartment.

3.Turn remote wall switch to “OFF.”

4.Verify main line shut-off valve is open.

5.Push in gas control knob slightly and turn clockwise

to “OFF.”

CONTROL KNOB

Note: Knob cannot be turned from “PILOT” to “OFF” unless the knob is pushed in slightly. Do not force.

6.Wait five (5) minutes to clear out any gas. If you then smell gas, STOP! Follow “B” in the safety information above on this page. If you do not smell gas, go to the next step.

7.Push in gas control knob slightly and turn counterclockwise

to “PILOT.”

8.Push in control knob all the way and hold in. Immediately light the pilot by triggering the spark ignitor (pushing the button) until pilot lights. Continue to hold the control knob in for about 1 ¹⁄₂ minutes after the pilot is lit. Release knob and it will pop back up. Pilot should remain lit. If it goes out, repeat steps 5 through 8.

If knob does not pop up when released,

stop and immediately call your service technician or gas supplier.

If pilot will not stay lit after several tries, turn the control knob to “OFF” and call your service technician or gas supplier.

9.Turn gas control knob counterclockwise to “ON.”

10.Close lower control compartment.

10

TO TURN OFF GAS TO APPLIANCE

1.

Turn remote wall switch “OFF.” The pilot will remain lit for

4.

Depress gas control knob slightly and turn clockwise

 

normal service.

 

 

to “OFF.” Do not force.

 

 

 

2.

For complete shutdown, turn remote wall switch to “OFF.”

5.

Close lower control compartment.

 

 

3.Access the lower control compartment.

Image 10
Contents 725,029M REV. C 07/2004 Retain These InstructionsVented GAS Fireplaces GRD-5500 SHOWNGHC-5500PGRD-5500NTable of Contents CongratulationsControl Compartment Access GHC-5500 Units Gas Controls/Control Compartment AccessControl Compartment Access GRD-5500 Units Operation and Care of Your ApplianceElectronic Appliance Lighting Millivolt Appliance LightingOutside Combustion Air Controls Firebox Wrapper Limit Switch Screws MaintenanceManual Reset Limit Switch Lintel Burner Adjustments Flame Appearance and SootingMaintenance Task Accomplishing Person Procedure Maintenance ScheduleMaintenance Task Accomplishing Person Millivolt Appliance Checkout Logs and Rockwool Glowing Embers PlacementElectronic Appliance Checkout LOG Placement Electronic System Wiring Without Forced Air Kit WarrantyReplacement Parts Product Reference InformationLighting Instructions Lighting Instructions Millivolt GAS ValveTo Turn OFF GAS to Appliance Instructions Dallumage Instructions D’ALLUMAGE Vanne GAZ MillivoltPour Fermer LE GAZ QUI Alimente L’APPAREIL What to do if YOU Smell GAS Lighting Instructions ElectronicTo Shut OFF Fermez la porte du compartiment de contrôle du bas Instructions D’ALLUMAGE ElectronicPilot burning, no gas to Wall switch or wires Lighting instructions Switch wiring On generatorDefective limit switch Wall switch onTroubleshooting the Electronic Ignition System Symptom Possible Causes Corrective ActionHorizontal Trim Installation Accessory ComponentsStandard Remote Control System Model RCL Aluminum-Framed Bi-Fold DoorsGRD-5500 Replacement Parts List Millivolt SystemGAS CONTROLS- Robertshaw Millivolt GHC/GRD-5500Replacement Parts Millivolt Replacement Parts List Electronic System GAS CONTROLS- Robertshaw ElectronicReplacement Parts Electronic Manufactured by LHP 725,029M REV. C 07/2004