ACCESSORY COMPONENTS

Remote Control System (Standard) H0249

RCL

Standard Remote Control System (Model RCL)

The Model RCL (Standard) Remote Control System, features a simplistic on/off control function for the fireplace. This model includes

ahand-held transmitter, a remote receiver with wall-mount coverplate and all hardware required to install the unit. The remote re- ceiver can be wall or hearth mounted.

The transmitter has ON and OFF functions that are activated by pressing either button on the face of the transmitter. When a button on the transmitter is pressed, a signal light illuminates briefly to verify that a signal has been sent.

The Model RCL is designed to operate with all millivolt ignition systems, as well as electronic ignition systems. It may be installed with use for either natural or propane gas appliances. The RCL offers ease of installation and allows you to execute on-off commands to the fireplace effort- lessly with one simple motion.

The Model RCL comes complete with detailed operating instructions.

Bi-Fold Doors

12M05

33ABF

 

12M06

33ABF-BB

Aluminum-Framed Bi-Fold Doors

Your appliance can be fitted with beautiful aluminum-framed bi-fold doors. Model 33ABF doors are available for use with these appli- ances. Doors are easily fitted to the fireplace opening. Model 33ABF doors come with stan- dard black finish. Model 33ABF-BB doors have a beautiful brass finish.

Twin Pane Door

12M42

33TBA-BB

 

 

 

Twin Pane Door

12M43

35TBA-BB

Aluminum-Framed Twin Pane Door

Your appliance can be fitted with beautiful aluminum-framed twin pane doors. Models 33TBA-BB and 35TBA-BB doors are available for use with these appliances. Doors are easily fitted to the fireplace opening. Both models come with a beautiful bright brass finish.

Glass Enclosure Panels

12M47

33AGEP

 

12M48

33AGEP-BB

 

12M49

35AGEP

 

12M50

35AGEP-BB

Glass Enclosure Panels

Your appliance can be fitted with beautiful glass enclosure panels. Model 33AGEP and 35AGEP doors are available for use with these appliances. Doors are easily fitted to the fire- place opening. Model 33AGEP and 35AGEP doors come with a standard black finish. Model 33AGEP-BB and 35AGEP-BB doors come with beautiful bright brass finish.

To ensure warranty and to prevent a potential fire hazard, do not use any other doors on these appliances.

NOTE: DIAGRAMS & ILLUSTRATIONS NOT TO SCALE.

Forced Air Kit

011781 FAK-1500

 

 

Forced Air Kit

051331 FAB-1600

with Variable Speed Wall Switch

 

Forced Air Kit

If the optional forced air kits, Model FAK-1500 or Model FAB-1600, are to be used on the GHC-5500 Series appliances, refer to the installation in- structions packed with the fan kit. The GHC- 5500 Series appliances have been pre-wired at the factory to accept the forced air kit at some later time. The appliance, must however, be connected to the main power supply at the time of installation if the either of the forced air kits are to be installed later. The FAB-1600 kit comes with a variable speed wall switch.

Horizontal Trim Kit

024477

35HTK-SPB

 

 

 

Horizontal Trim Kit

024474

35HTK-PB

Horizontal Trim Installation

There are two (2) optional horizontal trim kits, Models 35HTK-PB, 35HTK-SPB available for use with the GHC Series appliance. The 35 HTK-SPB kit's trim is solid polished brass, as opposed to the 35HTK-PB kit's trim which has a polished brass coating. Refer to the specific installation instructions packed with each trim kit for their proper usage and installation.

Image 16
Contents Retain These Instructions Vented GAS Fireplaces725,029M REV. C 07/2004 GRD-5500 SHOWNGHC-5500PGRD-5500NTable of Contents CongratulationsGas Controls/Control Compartment Access Control Compartment Access GRD-5500 UnitsControl Compartment Access GHC-5500 Units Operation and Care of Your ApplianceElectronic Appliance Lighting Millivolt Appliance LightingOutside Combustion Air Controls Maintenance Manual Reset Limit Switch LintelFirebox Wrapper Limit Switch Screws Burner Adjustments Flame Appearance and SootingMaintenance Task Accomplishing Person Procedure Maintenance ScheduleMaintenance Task Accomplishing Person Millivolt Appliance Checkout Logs and Rockwool Glowing Embers PlacementElectronic Appliance Checkout LOG Placement Warranty Replacement PartsElectronic System Wiring Without Forced Air Kit Product Reference InformationLighting Instructions Lighting Instructions Millivolt GAS ValveTo Turn OFF GAS to Appliance Instructions Dallumage Instructions D’ALLUMAGE Vanne GAZ MillivoltPour Fermer LE GAZ QUI Alimente L’APPAREIL What to do if YOU Smell GAS Lighting Instructions ElectronicTo Shut OFF Fermez la porte du compartiment de contrôle du bas Instructions D’ALLUMAGE ElectronicLighting instructions Switch wiring On generator Defective limit switchPilot burning, no gas to Wall switch or wires Wall switch onTroubleshooting the Electronic Ignition System Symptom Possible Causes Corrective ActionAccessory Components Standard Remote Control System Model RCLHorizontal Trim Installation Aluminum-Framed Bi-Fold DoorsReplacement Parts List Millivolt System GAS CONTROLS- Robertshaw MillivoltGRD-5500 GHC/GRD-5500Replacement Parts Millivolt Replacement Parts List Electronic System GAS CONTROLS- Robertshaw ElectronicReplacement Parts Electronic Manufactured by LHP 725,029M REV. C 07/2004