TOA Electronics P0055-DRG Maintenance Schedule, Maintenance Task Accomplishing Person Procedure

Page 6

6

Maintenance Schedule

Annually (Before the onset of the Burning Season)

Maintenance Task

Accomplishing Person

Procedure

 

 

 

 

Inspecting/Cleaning Burner, Logs

Qualified Service Technician

Inspect valve and ensure it is properly operat-

and Controls

 

ing. Check piping for leaks.

Vacuum the

 

 

control compartment, fireplace logs and burner

 

 

area.

 

 

 

 

Check Flame Patterns and Flame Height

Qualified Service Technician

Refer to Figure 10 on page 7 and verify the

 

 

flame pattern and height displayed by the

 

 

appliance conforms to the picture.

 

 

 

 

Inspecting/Cleaning Pilot and Burner

Qualified Service Technician

Refer to Figure 11 on page 7.

Remove any

 

 

surface build-up on pilot and burner assem-

 

 

bly. Wipe the pilot nozzles, ignitor/flame rod

 

 

and hood. Ensure the pilot flame engulfs the

 

 

flame sensor as shown.

 

 

 

 

Checking Vent System

Qualified Service Technician

Inspect the vent system at the top and at the

 

 

base (within the firebox) for signs of blockage

 

 

or obstruction. Look for any signs of disloca-

 

 

tion of the vent components.

 

 

 

 

Appliance Checkout

Qualified Service Technician

Perform the appropriate appliance checkout

 

 

procedure detailed in this manual.

 

 

 

Replacing Rockwool Ember Materials

Homeowner/Qualified Services Technician

Remove old ember materials and vacuum the

 

 

rockwool placement area. Place new rockwool

 

 

as described in this document.

 

 

 

 

 

Periodically (After the Burning Season)

 

 

 

 

 

 

 

Maintenance Task

Accomplishing Person

Procedure

 

 

 

 

Cleaning Firebox Interior

Homeowner

Carefully remove logs, Rockwool and volcanic

 

 

stone if used. Vacuum out interior of the

 

 

firebox. Clean firebox walls and log grate.

 

 

Replace logs, Rockwool and volcanic stone as

 

 

detailed in this manual.

 

 

 

 

Check Flame Patterns and Flame Height

Homeowner

Refer to Figure 10 on page 7 and verify the

 

 

flame pattern and height displayed by the

 

 

appliance conforms to the picture. Flames

 

 

must not impinge on the logs.

 

 

 

 

Checking Vent System

Homeowner

Inspect the vent system at the top and at the

 

 

base (within the firebox) for signs of blockage

 

 

or obstruction. Look for any signs of disloca-

 

 

tion of the vent components.

 

 

 

 

Cleaning Optional Glass Doors

Homeowner

Clean as necessary following the directions

 

 

provided in this manual. DO NOT TOUCH OR

 

 

ATTEMPT TO CLEAN DOORS WHILE THEY

 

 

ARE HOT.

 

 

 

 

 

Image 6
Contents 725,029M REV. C 07/2004 Retain These InstructionsVented GAS Fireplaces GRD-5500 SHOWNGHC-5500PGRD-5500NTable of Contents CongratulationsControl Compartment Access GHC-5500 Units Gas Controls/Control Compartment AccessControl Compartment Access GRD-5500 Units Operation and Care of Your ApplianceMillivolt Appliance Lighting Electronic Appliance LightingOutside Combustion Air Controls Firebox Wrapper Limit Switch Screws MaintenanceManual Reset Limit Switch Lintel Burner Adjustments Flame Appearance and SootingMaintenance Schedule Maintenance Task Accomplishing Person ProcedureMaintenance Task Accomplishing Person Logs and Rockwool Glowing Embers Placement Millivolt Appliance CheckoutElectronic Appliance Checkout LOG Placement Electronic System Wiring Without Forced Air Kit WarrantyReplacement Parts Product Reference InformationLighting Instructions Millivolt GAS Valve Lighting InstructionsTo Turn OFF GAS to Appliance Instructions D’ALLUMAGE Vanne GAZ Millivolt Instructions DallumagePour Fermer LE GAZ QUI Alimente L’APPAREIL Lighting Instructions Electronic What to do if YOU Smell GASTo Shut OFF Fermez la porte du compartiment de contrôle du bas Instructions D’ALLUMAGE ElectronicPilot burning, no gas to Wall switch or wires Lighting instructions Switch wiring On generatorDefective limit switch Wall switch onTroubleshooting the Electronic Ignition System Symptom Possible Causes Corrective ActionHorizontal Trim Installation Accessory ComponentsStandard Remote Control System Model RCL Aluminum-Framed Bi-Fold DoorsGRD-5500 Replacement Parts List Millivolt SystemGAS CONTROLS- Robertshaw Millivolt GHC/GRD-5500Replacement Parts Millivolt Replacement Parts List Electronic System GAS CONTROLS- Robertshaw ElectronicReplacement Parts Electronic Manufactured by LHP 725,029M REV. C 07/2004