Schlage L-SERIES manual L9080EL-RX Request To Exit RX Electrified L9080EU-RX Lock

Page 12

L Functions

Mortise Locks—Keyed

SCHLAGE

ANSI

 

L9080EL-RX

Request To Exit (RX) Electrified

L9080EU-RX

Lock

 

 

 

Same as L9080EL and L9080EU

 

 

 

 

 

 

functions. In addition, a micro switch

 

 

 

 

 

 

positioned inside the lock case

 

 

 

monitors the retractor crank, and is

 

 

 

 

 

 

 

 

 

actuated when rotation of the inside or

 

 

 

outside knob/lever rotates the retractor

 

 

 

 

 

 

hub. The switch signals the use of that

 

 

 

opening to security systems, allowing

 

 

 

a non-disruptive means of immediate

 

 

 

egress. Specify per L283-059 for

 

 

 

normally closed contacts (default).

 

 

 

Specify L283-125 for normally open

 

 

 

contacts. (Previously XL11-807)

L9082

 

Institution Lock*

 

 

 

Latchbolt retracted by key from either

 

 

 

 

 

 

side. Knob/lever on both sides always

 

 

 

inoperative. Auxiliary latch deadlocks

 

 

 

latchbolt when door is closed.

 

 

 

 

 

 

L9082 Electrically Locked or

 

 

 

 

 

 

L9082EL

 

L9082EU

 

Electrically Unlocked Both Sides*

 

 

 

EL: Outside and inside knob or lever

 

 

 

 

 

 

continually locked electrically.

 

 

 

Latchbolt retracted by key either side.

 

 

 

 

 

 

Switch or power failure allows outside

 

 

 

 

 

 

and inside knob/lever to retract

 

 

 

 

 

 

latchbolt. Auxiliary latch deadlocks

 

 

 

 

 

 

latchbolt when door is closed.

 

 

 

EU: Outside and inside knob/lever

 

 

 

unlocked electrically. Latchbolt

 

 

 

retracted by key either side. Switch or

 

 

 

power failure keeps inside and outside

 

 

 

knob/lever locked. Auxiliary latch

 

 

 

deadlocks latchbolt when door is

 

 

 

closed. (Previously XL11-452)

L9453

F20

Entrance Lock

 

 

 

Latchbolt retracted by knob/lever from

 

 

 

 

 

 

either side unless outside is locked by 20°

 

 

 

rotation of thumbturn. Deadbolt thrown or

 

 

 

retracted by 90° rotation of thumbturn.

 

 

 

 

 

 

When locked, key outside or knob/lever

 

 

 

 

 

 

 

 

 

inside retracts deadbolt and latchbolt

 

 

 

 

 

 

simultaneously. Outside knob/lever

 

 

 

remains locked until thumbturn is restored

 

 

 

to vertical position. Throwing deadbolt

 

 

 

automatically locks outside knob/lever.

 

 

 

Auxiliary latch deadlocks latchbolt when

 

 

 

door is closed.

Mortise Locks—Keyed

SCHLAGE

 

 

ANSI

 

L9456

 

 

F13

Corridor Lock

 

 

 

 

 

Latchbolt retracted by knob/lever from

 

 

 

 

 

 

 

 

 

 

either side. Deadbolt thrown or retracted

 

 

 

 

 

by key outside or inside thumbturn.

 

 

 

 

 

Throwing deadbolt locks outside

 

 

 

 

 

 

 

 

 

 

knob/lever. Turning inside knob/lever

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

simultaneously retracts deadbolt and

 

 

 

 

 

 

 

 

 

 

latchbolt and unlocks outside knob/lever.

L9457

 

 

Classroom Security Lock

 

 

 

 

Latchbolt retracted by knob/lever from

 

 

 

 

 

 

 

 

either side. Deadbolt thrown or retracted

 

 

 

 

by key from either side. Throwing

 

 

 

 

deadbolt locks outside knob/lever.

 

 

 

 

 

 

 

Turning inside knob/lever simultaneously

 

 

 

 

 

 

 

 

 

 

retracts deadbolt and latchbolt and unlocks

 

 

 

 

 

 

 

 

outside knob/lever.

L9465

 

 

 

Closet/Storeroom Lock

 

 

 

 

 

Latchbolt retracted by knob/lever from

 

 

 

 

 

 

 

 

 

 

either side. Deadbolt thrown or retracted

 

 

 

 

 

by key outside.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L9466

 

 

F14

Store/Utility Room Lock*

 

 

 

 

 

Latchbolt retracted by knob/lever from

 

 

 

 

 

 

 

 

 

 

either side. Deadbolt thrown or retracted

 

 

 

 

 

by key from either side.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

L9473

 

 

F21

Dormitory/Bedroom Lock

 

 

 

 

 

Latchbolt retracted by knob/lever from

 

 

 

 

 

 

 

 

 

 

either side. Deadbolt thrown or retracted

 

 

 

 

 

by key outside or thumbturn inside.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

*Caution: Double cylinder locks on residences and any door in any structure which is used for egress are a life safety hazard in times of emergency and their use is not recommended. Installation should be in accordance with existing codes only.

10

Image 12
Contents Series Extra Heavy Duty Mortise Locks Specifications Exposed TrimPerformance Features Cutaway ViewDoor Preparation Lever Designs & Finishes 625626 Knob Designs & Finishes FinishesMediterranean Designs & Finishes MeranoEscutcheons, Roses, Special Turns & Finishes Full FaceFunctions 4 53 P Cylinder SuffixFunction Lock SeriesMortise Locks-Non-Keyed L9010 F01 Passage LatchL9040 F22 Bath/Bedroom Privacy Lock L9044 Privacy With Coin Turn OutsideMortise Locks-Keyed L9050 F04 Office and Inner Entry LockL9056 L9060 F09 Apartment Entrance LockL9080EL-RX Request To Exit RX Electrified L9080EU-RX Lock L9082 Institution LockL9082 Electrically Locked or L9082EL L9082EU Electrically Unlocked Both SidesHotel Lock w/ Do Not Disturb Indicator L9480 L9485 L9486 F15Storeroom Lock With Deadbolt L9486 Hotel LockDeadbolt With Occupied Indicator Mortise Locks-Keyed DeadlocksL9460 F17 Cylinder x Thumbturn Lock L9462 F16 Double Cylinder LockSpecial Functions L9110 Double Dummy With Active Trim L9482L9040 Privacy With Turns Both Sides L9485 L9460 L9460 With Fixed Dummy TrimStandard Cylinders Primus High Security CylindersPrimus Lockout Cylinders Standard Non-IC Cylinders Standard Non-IC Mortise CylindersEscutcheons Full Size Interchangeable Core Cylinders Full Size IC Mortise CylindersFull Size Interchangeable Cores Only Small Format Interchangeable Core Sfic Cylinders Small Format Interchangeable Core CylindersSmall Format Interchangeable Core Only Core MechanismIC Installation Tool L400 and L9000 SeriesL9060 Outside Only Dimension Blocking and Compression RingsFull Size Core Blocking Ring Requirements Blocking Ring LengthElectrified Locks L9080PEL L9080PEUArmored Fronts Armored FrontsStandard Square Corner Standard Square Corner Armor StrikeDoor Handing Pull and rotateRelocate catch screw Left Hand Reverse BevelHow to Order 626626 625 605Administrative Offices