5.5 Connecting the REMOTE Connector

You can force the routing of one of the 2 inputs to the XGA output by remote control. To do so, connect the appropriate REMOTE input terminal block connector pins to a dry contact switch1. For example, as Figure 6 illustrates, to route REMOTE IN 1 to the XGA output, connect PIN 1 to the Ground. To route REMOTE IN 2 to the XGA output, connect PIN 2 to the Ground pin. Do not connect both the REMOTE IN 1 and the REMOTE IN 2 to the Ground pin simultaneously.

Route input 1 to the output, by attaching PIN 1 to the Ground:

Route input 2 to the output, by attaching PIN 2 to the Ground:

Figure 6: Remote Terminal Block Connector

When both XGA INPUT 1 and XGA INPUT 2 are connected, the signal from XGA INPUT 1 routes to the output (factory default). However, you can force the routing of XGA INPUT 2 to the output by attaching PIN 2 to the Ground. Even if no input is present on XGA INPUT 1, you can force the routing of the output from XGA INPUT 1 (displaying a blank screen) by attaching PIN 2 to the Ground.

1 Note that the connection should be permanent, since the WP-211DS will revert to an automatic switcher when the connection is removed

9

Image 12 Contents
Model Contents Tables2900-9999992 About the Power Connect Feature IntroductionGetting Started OverviewShielded Twisted Pair STP / Unshielded Twisted Pair UTP About the WP-211DSYour WP-211DS Recommendations for Achieving the Best PerformanceDefine the rear panel of the WP-211DS Using the WP-211DS Installing the WP-211DSWiring the CAT5 Line in / Line OUT RJ-45 Connectors CAT5 PinoutConnecting the WP-211DS Example of a WP-211DS InstallationOperating using the Default Master Source Signal Selection Connecting the Remote Connector Remote Terminal Block ConnectorTechnical Specifications Includes the technical specificationsOnly the first purchase customer may enforce this warranty 2900-78 REV