80 OUTPUT DEFINITIONS

Fill in the required data on the worksheet below and follow the programming procedure in the installation manual as you enter the data during the displays and prompts that appear in sequence.

Notes: 1. For Relays, 4229 and 4204 devices are programmed in *79, *80, and *81 modes.

2.For Powerline Carrier devices (plcd), field 27 must be programmed with a House Code.

3. Tampers of expansion units cannot be used to operate devices.

Output

Activation Type and Detail

 

Partition

Event (for zone list/activated by)

Action

Output

Device

Function

Activated by

Zone List

Zone Type

Zone No.

Number

 

By Zone List

By Zone No.

0 = off

Number

Type

Number

0=delete

(ZL)

(ZT)

(ZN)

 

(P)

 

 

 

1 = close 2 secs

 

 

(FA168CPS:

1=zn list

1-8 = list

(see table

00=none

 

(if using ZT trig)

0 = restore

0 = restore

2 = stay closed

FA168CPS:

R = relay

1-48)

2=zn type

 

below)

FA168CPS:

0 = any

1 = alarm

1 = alrm/flt/trbl

3 = pulse

1-18

T = trigger

(FA148CP:

3=zn no.

 

 

01-64

 

1 = partition 1

2 = fault

 

4 = toggle

 

X = X10

1-24)

 

 

 

FA148CP:

2 = partition 2

3 = trouble

 

5 = duration 1††

FA148CP:

 

 

 

 

01-06, 09-34,

 

 

 

 

 

 

 

3 = common

 

 

 

6 = duration 2††

1-8, 17, 18

 

 

 

 

 

 

49-56

 

 

 

 

 

 

 

 

1

 

 

 

 

 

 

 

 

 

 

 

 

2

 

 

 

 

 

 

 

 

 

 

 

 

3

 

 

 

 

 

 

 

 

 

 

 

 

4

 

 

 

 

 

 

 

 

 

 

 

 

5

 

 

 

 

 

 

 

 

 

 

 

 

6

 

 

 

 

 

 

 

 

 

 

 

 

7

 

 

 

 

 

 

 

 

 

 

 

 

8

 

 

 

 

 

 

 

 

 

 

 

 

9

 

 

 

 

 

 

 

 

 

 

 

 

10

 

 

 

 

 

 

 

 

 

 

 

 

11

 

 

 

 

 

 

 

 

 

 

 

 

12

 

 

 

 

 

 

 

 

 

 

 

 

13

 

 

 

 

 

 

 

 

 

 

 

 

14

 

 

 

 

 

 

 

 

 

 

 

 

15

 

 

 

 

 

 

 

 

 

 

 

 

16

 

 

 

 

 

 

 

 

 

 

 

 

17

 

 

 

 

 

 

 

 

 

 

 

 

18

 

 

 

 

 

 

 

 

 

 

 

 

19

 

 

 

 

 

 

 

 

 

 

 

 

20

 

 

 

 

 

 

 

 

 

 

 

 

21

 

 

 

 

 

 

 

 

 

 

 

 

22

 

 

 

 

 

 

 

 

 

 

 

 

23

 

 

 

 

 

 

 

 

 

 

 

 

24

 

 

 

 

 

 

 

 

 

 

 

 

25

 

 

 

 

 

 

 

 

 

 

 

 

26

 

 

 

 

 

 

 

 

 

 

 

 

27

 

 

 

 

 

 

 

 

 

 

 

 

28

 

 

 

 

 

 

 

 

 

 

 

 

29

 

 

 

 

 

 

 

 

 

 

 

 

30

 

 

 

 

 

 

 

 

 

 

 

 

31

 

 

 

 

 

 

 

 

 

 

 

 

32

 

 

 

 

 

 

 

 

 

 

 

 

33

 

 

 

 

 

 

 

 

 

 

 

 

34

 

 

 

 

 

 

 

 

 

 

 

 

35

 

 

 

 

 

 

 

 

 

 

 

 

36

 

 

 

 

 

 

 

 

 

 

 

 

37

 

 

 

 

 

 

 

 

 

 

 

 

38

 

 

 

 

 

 

 

 

 

 

 

 

39

 

 

 

 

 

 

 

 

 

 

 

 

40

 

 

 

 

 

 

 

 

 

 

 

 

41

 

 

 

 

 

 

 

 

 

 

 

 

42

 

 

 

 

 

 

 

 

 

 

 

 

43

 

 

 

 

 

 

 

 

 

 

 

 

44

 

 

 

 

 

 

 

 

 

 

 

 

45

 

 

 

 

 

 

 

 

 

 

 

 

46

 

 

 

 

 

 

 

 

 

 

 

 

47

 

 

 

 

 

 

 

 

 

 

 

 

48

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

ZONE TYPE/SYSTEM OPERATION – Choices for Zone Types are:

 

 

 

 

 

 

 

00 = Not Used

05 = Trouble Day/Alarm Night

10 = Interior w/Delay

 

24 = Silent Burglary

 

 

 

 

01 = Entry/Exit#1

06 = 24 Hr Silent

 

12 = Monitor Zone

 

77 = Keyswitch

 

 

 

 

02 = Entry/Exit#2

07 = 24 Hr Audible

 

14 = Carbon Monoxide

81 = AAV Monitor Zone

 

 

 

 

03 = Perimeter

08 = 24 Hr Aux

 

16 = Fire w/Verification

90-91 = Configurable

 

 

 

 

04 = Interior Follower

09 = Fire

 

 

23 = No Alarm Response

 

 

 

 

Choices for System Operation are:

 

 

 

 

20

= Arming–Stay

38

= Chime

52

= Kissoff

21

= Arming–Away

39

= Any Fire Alarm

54

= Fire Zone Reset

22

= Disarming (Code + OFF)

40

= Bypassing

58

= Duress

31

= End of Exit Time

41

= **AC Power Failure

60

= AAV Trigger

32

= Start of Entry Time

42

= **System Battery Low

66

= Function key†

33

= Any Burglary Alarm

43

= Communication Failure

67

= Bell Failure

36

= **At Bell Timeout***

 

 

68

= TELCO Line Fault

 

 

 

 

78

= Keyswitch red LED†††

 

 

 

 

79

= Keyswitch green LED†††

Note: In normal operation mode:

Code + # + 7 + NN Key Entry starts Device

Code + # + 8 + NN Key Entry stops Device

**Use 0 (any) for Partition No. (P) entry.

***Or at Disarming, whichever occurs earlier.

Use *57 Menu mode to assign the function key. †† Duration is set in program field *177.

††† Device action not used for these choices.

11

Image 11
Contents K5305-5PRV2 10/03 Rev. a $&36 $&3To Enter Programming Mode Zone Sounds and Timing 31 Installer CodeQuick ARM Enable RF JAM OptionPrimary Phone No 56, *57, *58 Menu ModesSystem Status Report Codes ∗79, *80, *81, *82 Menu Modes Restore Report Codes 70 76 71 72 73 74Output and System Setup 77 168 Download Information 94Pager Options 160 167Miscellaneous System Fields *174-*181 Configurable Zone Type Options *182-*185Touch Screen Device AUI Enable Field *182 EntryEntries for Fields *182 and *184 Entry Zone Type= EOL Reserved ZonesList No Used For… Contains These Zones… Zone Lists for Output DevicesFA168CPS Output DefinitionsAuxiliary Alarm Alarm by NightHour Silent Alarm Hour Audible AlarmDays 159 156157 213This Device Wireless Input TypesReports as †† Enabled By… For Loop Function Zone Type For 5804BDInc ¬.3594l K5305-5PRV2 10/03 Rev. a