Entries apply to both the FA168CPS and FA148CP controls, except entries shown in dashed boxes, which apply only to the FA168CPS (partition entries) and are not applicable to the FA148CP.
Entry of a number other than one specified will give unpredictable results. Values shown in brackets are factory defaults.
Field | Function | Data Entries |
| Programmable Values | ||||
SYSTEM SETUP |
|
|
|
|
|
|
| |
✱ 20 | INSTALLER CODE |
|
|
|
|
| 4 digits, | |
|
|
| [4112] | |||||
|
|
|
|
|
|
| ||
✱21 | QUICK ARM ENABLE | [0,0] |
| 0 = no; 1 = yes | ||||
|
|
|
|
| ||||
|
| Part. 1 Part.2 |
|
|
|
| ||
✱22 | RF JAM OPTION | [0] |
|
|
| 0 = no RF Jam detection; 1 = send RF Jam report | ||
|
|
|
|
| UL: must be 1 if wireless devices are used |
| ||
|
|
|
|
|
|
|
|
✱23 QUICK (FORCED) BYPASS
✱24 RF HOUSE ID CODE
✱26 CHIME BY ZONE
✱27 POWERLINE CARRIER DEVICE
HOUSE CODE
✱28 ACCESS CODE FOR PHONE MODULE
✱29 LONG RANGE RADIO OUTPUT
ZONE SOUNDS AND TIMING (✱31 – ✱39)
✱31 SINGLE ALARM SOUNDING per ZONE ✱32
✱33
[0,0]
Part. 1 Part. 2
Part. 1 Part. 2 Common
[0]
[0]
[00] |
(Partition 1 only)
[0]
[0]
[0]
[1]
0 = no quick bypass UL: must be “0”
1 = allow quick bypass (code + [6] + [#] )
00 = disable all wireless keypad usage
0 = no; 1 = yes (select zones to chime on zone list 3, using *81 Menu mode)
0 = A; 1 = B, 2 = C, 3 = D, 4 = E, 5 = F, 6 = G,
7 = H, 8 = I, 9 = J, #10 = K, #11 = L, #12 = M, #13 = N, #14 = O, #15 = P UL: not for fire or UL installations
00 = disable; 1st digit: enter
UL: must be “00” for UL Commercial Burg. installations
0 = disable; 1 = enable
0 = no UL: must be “0”; 1 = yes
0 = sounder stops at timeout;
1 = no sounder timeout UL: must be “1” for fire install.
0 = none; 1 = 4 min; 2 = 8 min; 3 =12 min; 4 = 16 min;
UL: For residential fire alarm installation, must be set for a minimum of 4 min (option 1); for UL Commercial Burglary installations, must be minimum 16 min (option 4)
✱34
✱35
[60,60] | ||
Part. 1 | Part. 2 |
|
| [30,30] | |
Part. 1 | Part. 2 |
|
Common zones use same delay as partition 1.
00 - 96 = 0 - 96 secs; 97 = 120 secs
SIA Installations: minimum exit delay is 45 seconds
UL: see inst. instr. for requirements.
Common zones use same delay as partition 1.
00 | - 96 = 0 - 96 seconds |
|
97 | = 120 seconds | SIA Installations: |
98 | = 180 seconds | minimum entry delay is |
99 | = 240 seconds | 30 seconds |
For UL Residential Burglary Alarm installations, must be set for a maximum of 30 seconds; entry delay plus dial delay should not exceed 1 min. For UL Commercial Burglar Alarm, total entry delay may not exceed 45 seconds.
✱36
∗37
[30,30] | ||
Part. 1 | Part. 2 |
|
[1,1]
See *35 Entry Delay 1 above for entries.
0 = no; 1 = yes
SIA Installations: must be enabled (enter 1)
✱38
[0,0] | 0 | = no; 1 = yes (wired keypads and RF) | |
2 | = yes, RF only | ||
|
Part. 1 Part. 2
✱39 | POWER UP IN PREVIOUS STATE | [1] |
|
|
DIALER PROGRAMMING (✱40 – ✱42)
UL: must be “1” for UL Commercial Burglar Alarm inst.
0 = no; 1 = yes UL: must be “1”
Do not fill unused spaces. Enter
✱40 PABX ACCESS CODE
Enter up to 6 digits. To clear entries, press ✱40✱. If call waiting
used, enter “∗ (#+11) 70” plus “# + 13” (pause).
✱ 41 | PRIMARY PHONE No. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
✱ 42 | SECOND PHONE No. |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Enter up to 20 digits. To clear entries, press ✱41✱ or ✱42✱ respectively.
– 3 –