✱92 PHONE LINE MONITOR ENABLE
UL: see Inst. Instructions for requirements
[0,0]
1 2
NOTE: Output Device must either be programmed to be STOPPED in field ✱80 or STOPPED by Code + # + 8 + output number.
Entry 1:: 0 = disabled,
(#+10 = 10 min; #+11 = 11 min; #+12 = 12 min; #+13 = 13 min; #+14 = 14 min; #+15 = 15 min)
Entry 2:
0 = Keypad display when line is faulted
1 = Keypad display plus keypad trouble sound
2 = Same as “1”, plus programmed output device STARTS. If either partition is armed, external sounder activates also.
✱93 | No. OF REPORTS IN ARMED PERIOD | [1] |
| PER ZONE (Swinger Suppression) | |
|
|
0 = Unlimited Reports; 1 = 1 report; 2 = 2 reports UL: must be “0”
SIA Installations: Must be set for option 1 or 2.
DOWNLOAD INFORMATION (✱94, ✱95)
✱94 DOWNLOAD PHONE No.
Enter up to 20 digits,
✱95 RING COUNT FOR DOWNLOADING
∗96, ∗97 INITIALIZE/RESET DEFAULTS ∗98, *99 EXIT COMMANDS
PAGER OPTIONS (✱160- ✱172)
0 = Disable Station Initiated Download;
# +12 =12, # +13 =13, # +14 =14);
15 = answering machine defeat (# +15 =15).
These are commands, not data fields. See page 2.
These are commands, not data fields. See page 2.
✱160 PAGER 1 PHONE No.
Enter up to 20 digits.
✱161 PAGER 1 CHARACTERS
✱162 PAGER 1 REPORT OPTIONS
Enter the optional prefix characters, up to 16 digits.
For each partition, select from the following options:
0 = no reports sent
1 = Open/closes all users
4 = All alarms and troubles
5 = All alarms / troubles, and open/closes for all users 12 = Alarms / troubles for zones entered in zone list 9 13 = Alarms / troubles for zones entered in zone list 9,
and open/closes for all users
✱163 PAGER 2 PHONE No.
Enter up to 20 digits.
✱164 PAGER 2 CHARACTERS
✱165 PAGER 2 REPORT OPTIONS
Enter the optional prefix characters, up to 16 digits.
[0,0,0] See field *162 for reporting options. Select for each partition (use zone list 10 if using options 12 or 13).
Part. 1 Part. 2 common
✱166 PAGER 3 PHONE No. |
|
Enter up to 20 digits.
✱167 | PAGER 3 | CHARACTERS | |||||||||||||
|
|
| Enter the optional prefix characters, up to 16 digits. | ||||||||||||
|
|
| |||||||||||||
✱168 | PAGER 3 REPORT OPTIONS |
|
|
| 0,0,0] |
| See field *162 for reporting options. Select for each | ||||||||
|
|
| Part. 1 Part. 2 | common | partition (use zone list 11 if using options 12 or 13). | ||||||||||
✱169 | PAGER 4 | PHONE No. |
|
Enter up to 20 digits.
✱170 PAGER 4 CHARACTERS
✱171 PAGER 4 REPORT OPTIONS
✱172 PAGER DELAY OPTION FOR ALARMS
|
|
| |
Enter the optional prefix characters, up to 16 digits. | |||
|
| [0,0,0] | See field *162 for reporting options. Select for each |
Part. 1 Part. 2 | common | partition (use zone list 12 if using options 12 or 13). | |
| [3] |
| 0 = none, 1 = 1 minute, 2 = 2 minutes, 3 = 3 minutes |
|
| ||
|
| This delay is for ALL pagers in the system. | |
|
|
|
– 6 –