TO ENTER PROGRAMMING MODE:
Local programming requires the use of an alpha keypad connected to the keypad terminals on the control.
A.POWER UP, then depress [✱] and [#] both at once, within 50 seconds of powering up (if ✱98 was used to exit program mode, this method must be used to reenter program mode).
OR
B.Initially, key: Installer Code (4 + 1 + 1 + 2) plus 8 + 0 + 0.
DATA FIELD PROGRAMMING PROCEDURES
Task | Procedure |
Go to a Data Field | Press [∗] + [Field Number], followed by the required entry. |
Entering Data | When the desired field number appears, simply make the required entry. When the last entry for a |
| field is entered, the keypad beeps three times and automatically displays the next data field in |
| sequence. |
| If the number of digits that you need to enter in a data field is less than the maximum digits available |
| (for example, the phone number fields *41, *42), enter the desired data, then press [∗ ] to end the |
| entry. The next data field number is displayed. |
|
|
Review a Data Field | Press [#] + [Field Number]. |
| Data will be displayed for that field number. No changes will be accepted in this mode. |
Deleting an Entry | Press [∗] + [Field Number] + [∗]. (Applies only to fields ∗40 thru *46, *94, and pager programming |
| fields) |
INTERACTIVE MODE PROGRAMMING (∗56, ∗57, ∗58, ∗79, ∗80, ∗81, ∗82, ∗187)
Press [✱] + [Interactive Mode No.] (for example, ✱56). The alpha display keypad will display the first of a series of prompts requesting entries.
Interactive Mode | Used to Program | |
✱56 Zone Programming | Zone characteristics, report codes, alpha descriptors, and serial numbers for 5800 RF | |
|
| transmitters. |
|
| |
✱57 Function Key Programming | Unlabeled keypad keys (known as ABCD keys) for special functions | |
|
| |
✱58 Zone Programming | Same options as *56 mode, but with fewer prompts. Intended for those familiar with | |
(Expert mode) | this type of programming, otherwise *56 mode is recommended. | |
|
|
|
✱79 | Output Device Mapping | Assign module addresses and map individual relays/powerline carrier devices |
|
|
|
✱80 | Output Programming | 4229 or 4204 Relay modules, Powerline Carrier devices, or |
✱81 | Zone List Programming | Zone Lists for relay/powerline carrier activation, chime zones, pager zones, etc. |
✱82 | Alpha Programming | Zone alpha descriptors |
INITIALIZE DOWNLOAD and RESET DEFAULTS
✱96 Initializes download ID and subscriber account number. ✱97 Sets all data fields to original factory default values.
TO EXIT PROGRAMMING MODE:
✱98 Exits programming mode and prevents
See field *88 for other *98 Program mode lockout options.
✱99 Exits programming mode and allows
Special Messages
OC = OPEN CIRCUIT (no communication between Keypad and Control).
EEor ENTRY ERROR = ERROR (invalid field number entered;
After powering up, AC, dI (disabled) or Busy Standby and NOT READY will be displayed after approximately 4 seconds. This will revert to a “Ready” message in approximately 1 minute, which allows PIRS, etc. to stabilize. You can bypass this delay by pressing [#] + [0].
If E4 or E8 appears, more zones than the expansion units can handle have been programmed. The display will clear after you correct the programming.
– 2 –