Kenmore 153.339482 Important Information about this Water Heater, Installation Checklist

Page 11
instructions (See “Water Temperature Regulation” section).
Gas Supply and Piping
Gas type is the same as that listed on the water heater rating plate.
Gas line equipped with shut-off valve, union, and drip leg.
Use pipe joint compound or teflon tape marked as being resistant to the action of petroleum [Propane (L.P.)] gases.
Adequate pipe size and approved pipe material.
An approved noncorrosive leak detection solution used to check all connections and fittings for possible gas leaks. Correct any leak found.
Mixing valve (when applicable) installed per manufacturer’s
Closed system pressure build-up devices installed.
All piping properly installed and free of leaks.
Heater completely filled with water.
correctly.
Vent pipe system installed according to all local and state codes or, in the absence of local and state codes, the “National Fuel Gas Code”, ANSI Z223.1(NFPA 54)-current edition.
Flue baffle properly positioned in the flue tube.
Check the vent system for restrictions/obstructions and check the vent termination height. Refer to the “Combustion Air Supply and Ventilation” section of this water heater manual for specific requirements.
Recheck for sufficient combustion air supply.
Water System Piping
Temperature and pressure relief valve properly installed with a discharge line run to an open drain and protected from freezing.

IMPORTANT INFORMATION ABOUT THIS WATER HEATER

This gas water heater was manufactured to voluntary safety standards to reduce the likelihood of a flammable vapor ignition incident. The new technology used in meeting these standards makes this product more sensitive to installation errors. Please review the following checklist and make any required installation upgrades or changes.

Questions? Contact Sears at 1-800-4-MY-HOME (1-800-469-4663).

Installation Checklist

Water Heater Location

Water heater location is important and can affect system performance. Please check the following:

Installation area free of corrosive elements and flammable materials.

Centrally located with the water piping system (For new installations). Located as close to the gas piping and vent pipe system as possible.

Located indoors and in a vertical position. Protected from freezing temperatures.

Proper clearances from combustible surfaces maintained and not installed directly on a carpeted floor.

Provisions made to protect the area from water damage. Metal drain pan installed and piped to an adequate drain.

Sufficient room to service the water heater. See Clearances and Accessibility section of this manual.

Water heater not located near an air moving device.

Is the installed environment dirty (excessive amounts of lint, dirt, dust, etc.)? If so, the base-ring filter located on the bottom of the water heater will need to be cleaned periodically. Refer to the “Maintenance of your Water Heater” section of this manual for information on cleaning the base-ring filter.

Combustion Air Supply and Ventilation

Check for sufficient combustion air supply. Insufficient air for the combustion of gas will result in the flame becoming “lazy”, thereby allowing heat to build up in the combustion chamber. This excessive heat will cause a thermal switch on the door assembly to trip. Is the water heater installed in a closet or other small, enclosed space? If so:

Are there openings for make-up air to enter and exit the room/area?

Are the openings of sufficient size? Remember, if there are other gas-fired or air-consuming appliances in the same room, you need more make-up air. Refer to the “Installation Instructions” and “Combustion Air Supply and Ventilation” sections for specific requirements.

Make sure that fresh air is not taken from areas that contain negative pressure producing devices such as exhaust fans, dryers, fireplaces, etc.

Fresh air openings must be sized correctly with consideration given to the blocking effect of louvers and grilles.

Ductwork must be the same cross-sectional area as the openings.

Vent Pipe System

Check for proper drafting at the water heater draft hood. Refer to the “Checking the Draft” section of this manual for the test procedure. If the procedure shows insufficient draft is present, please check the following:

Draft hood properly installed.

Vent connectors securely fastened with screws and supported properly to maintain six inch clearance.

Vent connector made of approved material and sized

Is there a furnace/air handler in the same room space as the water heater? If so, has a return air duct system been attached that exits the room? If so, check for leaks on the air duct system. If no air duct system is present, correct immediately by contacting a local Heating, Ventilation, Air- Conditioning & Refrigeration (HVAC-R) authorized service provider.

Use a fresh air supply that is free of corrosive elements and flammable vapors.

11

Image 11
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Power Miser 9 GAS Water HeaterSafety Precautions Safe INSTALLATION, USE and ServiceFire or Explosion Harzard Table of Contents Troubleshooting Guide Year Limited Warranty on Water Heater Product WarrantyImportant Information About This Water Heater Customer ResponsibilitiesJacket TOP Product SpecificationsMaterials Needed Materials and Basic Tools NeededGET to Know Your Water Heater GAS Models Typical InstallationImportant Information about this Water Heater Installation ChecklistRemoving the Old Water Heater Installation InstructionsSite Location Location RequirementsInsulation Blankets Clearances and AccessibilityGas Piping Filling the Water HeaterGAS Supply Gas RequirementsLP Gas Only Gas Pressure TestingGas Pressure All Air from Inside the Building Combustion AIR Supply & VentilationUnconfined Space Louvers and Grilles All Air from OutdoorsVent Pipe Size Draft Hood InstallationVent Connectors Vent Pipe SystemVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveLighting Instructions Operating Your Water HeaterEmergency Shut Down Water Temperature RegulationChecking the Draft Burner Flames110 Vent System Inspection Burner Inspection Service and AdjustmentTank Sediment Cleaning Burner CleaningDraining and Flushing Temperature-Pressure Relief Valve OperationHousekeeping Anode Rod InspectionService Maintenance of Your Water Heater Cleaning the Combustion Chamber and Flame-arrestor Replacing the Pilot/ Pilot Tube AssemblyPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyRemoving the Gas Valve Testing the Igniter SystemFvir System Operational Checklist Removing and Replacing the Gas Control Valve/ThermostatStart Up Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Problem Possible Causes Corrective Action Troubleshooting ChartThermostat Fails to YES Pilot Light Troubleshooting FlowchartModel Numbers Part Description Parts Order ListMY-HOME1-800-469-4663 Get it fixed, at your home or ours

153.339432, 153.339372, 153.33955, 153.339572, 153.339482 specifications

Kenmore, a brand synonymous with quality home appliances, offers a wide range of products designed to make household tasks more efficient and enjoyable. Among their notable offerings are models 153.339432, 153.339482, 153.33955, 153.339473, and 153.339372. These models stand out due to their innovative features, advanced technologies, and user-friendly characteristics.

The Kenmore 153.339432 model is recognized for its sleek design and powerful performance. It boasts an energy-efficient motor that not only reduces electricity consumption but also enhances the longevity of the appliance. This model is equipped with multiple speed settings, allowing users to tailor operations according to their specific needs, whether it’s for intensive cleaning or gentle care.

In contrast, the 153.339482 emphasizes versatility with its multi-function capabilities. This model accommodates a variety of cooking styles and methods, ranging from steaming to conventional baking. Its digital interface simplifies the cooking process, making it easy for users to navigate settings and timers, ensuring that meals are cooked to perfection every time.

The Kenmore 153.33955 is distinguished by its smart technology integration. This model can be controlled remotely via a smartphone app, providing the convenience of monitoring cooking from anywhere in the home. Users can set cooking times, adjust temperatures, and receive notifications when the food is ready, merging traditional cooking wisdom with modern technological advancements.

Model 153.339473 offers an enhanced safety profile, featuring automatic shut-off functions and child lock settings. This ensures peace of mind for families, particularly those with young children. The durable construction and high-quality materials used in this model further enhance safety and reliability, making it a top choice for parents.

Lastly, the Kenmore 153.339372 is engineered with sustainability in mind. It incorporates eco-friendly materials and processes, reducing its environmental footprint without compromising on performance. This model also features an intuitive energy-saving mode, which encourages users to optimize cooking habits and reduce waste.

Together, these Kenmore models exemplify the brand's commitment to innovation, safety, and environmental consciousness, catering to diverse consumer needs while ensuring quality and reliability in every use. With Kenmore, customers can trust that they are investing in products designed to enhance their daily lives.