Kenmore 153.339372, 153.339572, 153.33955, 153.339473 Troubleshooting Guide, Start Up Conditions

Page 33

TROUBLESHOOTING GUIDE

Start Up Conditions

Thermal Expansion

NOTE: Expansion tanks are pre-charged with a 40 psi air charge. If the inlet water pressure is higher than 40 psi, the expansion tank’s air pressure must be adjusted to match that pressure, but must not be higher than 80 psi.

As water is heated, it expands (thermal expansion). In a closed system, the volume of water will grow. As the volume of water grows, there will be a corresponding increase in water pressure due to thermal expansion. Thermal expansion can cause premature tank failure (leakage). This type of failure is not covered under the limited warranty. Thermal expansion can also cause intermittent temperature-pressure relief valve operation: water discharged from the valve due to excessive pressure build up. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This condition is not covered under the limited warranty.

A properly sized thermal expansion tank should be installed on all closed systems to control the harmful effects of thermal expansion. Thermal expansion tanks are available from Sears stores and through the Sears Service Centers. Contact the local plumbing inspector, water supplier and/or the Sears Service Center for assistance in controlling these situations. See Figure 42.

TABLE 5

Thermal Expansion Tank Specifications

 

Tank

Dimensions

Pipe

Model

Capacity

in Inches

 

Fitting

Number

In Gallons

Diameter

 

Length

On Tank

153.331020

2

8 (203 mm)

12-3/4 (323 mm)

3/4” Male

153.331050

5

11 (279 mm)

14-3/4 (375 mm)

3/4” Male

 

 

 

 

 

 

TABLE 6

Expansion Tank Sizing Chart

 

Inlet*

 

Water Heater Capacity (Gallons)

 

Water

 

 

 

 

 

 

Expansion

Pressure

 

30

40

50

66

82

40psi

2

2

2

5

5

Tank

50psi

2

2

2

5

5

Capacity

60psi

2

2

5

5

5

Needed

70psi

2

2

5

5

5

 

80psi

2

5

5

5

5

 

 

 

 

 

 

 

 

*Highest recorded inlet water pressure in a 24 hour period or regulated water pressure.

FIGURE 42.

Strange Sounds

Possible noises due to expansion and contraction of some metal parts during periods of heat-up and cool-down do not represent harmful or dangerous conditions.

Condensation causes sizzling and popping within the burner area during heating and cooling periods and should be considered normal. See “Condensation” section.

Draft Hood Operation

Check draft hood operation by performing a worst case depressurization of the building. With all doors and windows closed, and with all air handling equipment and exhaust fans operating such as furnaces, clothes dryers, range hoods and bathroom fans, a match flame should still be drawn into the draft hood of the water heater with its burner firing. If the flame is not

33

Image 33
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Power Miser 9 GAS Water HeaterSafety Precautions Safe INSTALLATION, USE and ServiceFire or Explosion Harzard Table of Contents Troubleshooting Guide Year Limited Warranty on Water Heater Product WarrantyImportant Information About This Water Heater Customer ResponsibilitiesJacket TOP Product SpecificationsMaterials Needed Materials and Basic Tools NeededGET to Know Your Water Heater GAS Models Typical InstallationImportant Information about this Water Heater Installation ChecklistRemoving the Old Water Heater Installation InstructionsSite Location Location RequirementsInsulation Blankets Clearances and AccessibilityGAS Supply Filling the Water HeaterGas Requirements Gas PipingGas Pressure Testing Gas PressureLP Gas Only Combustion AIR Supply & Ventilation Unconfined SpaceAll Air from Inside the Building Louvers and Grilles All Air from OutdoorsVent Connectors Draft Hood InstallationVent Pipe System Vent Pipe SizeVertical Exhaust Gas Vent Chimney ConnectionWater System Piping Piping InstallationClosed System/Thermal Expansion Temperature and Pressure Relief ValveLighting Instructions Operating Your Water HeaterChecking the Draft Water Temperature RegulationBurner Flames Emergency Shut Down110 Tank Sediment Cleaning Service and AdjustmentBurner Cleaning Vent System Inspection Burner InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection Draining and FlushingService Maintenance of Your Water Heater Cleaning the Combustion Chamber and Flame-arrestor Replacing the Pilot/ Pilot Tube AssemblyPiezoelectric Igniter System Replacing the Manifold/Burner AssemblyFvir System Operational Checklist Testing the Igniter SystemRemoving and Replacing the Gas Control Valve/Thermostat Removing the Gas ValveStart Up Conditions Troubleshooting GuideCondensation Operational ConditionsLeakage Checkpoints Problem Possible Causes Corrective Action Troubleshooting ChartThermostat Fails to YES Pilot Light Troubleshooting FlowchartModel Numbers Part Description Parts Order ListMY-HOME1-800-469-4663 Get it fixed, at your home or ours

153.339432, 153.339372, 153.33955, 153.339572, 153.339482 specifications

Kenmore, a brand synonymous with quality home appliances, offers a wide range of products designed to make household tasks more efficient and enjoyable. Among their notable offerings are models 153.339432, 153.339482, 153.33955, 153.339473, and 153.339372. These models stand out due to their innovative features, advanced technologies, and user-friendly characteristics.

The Kenmore 153.339432 model is recognized for its sleek design and powerful performance. It boasts an energy-efficient motor that not only reduces electricity consumption but also enhances the longevity of the appliance. This model is equipped with multiple speed settings, allowing users to tailor operations according to their specific needs, whether it’s for intensive cleaning or gentle care.

In contrast, the 153.339482 emphasizes versatility with its multi-function capabilities. This model accommodates a variety of cooking styles and methods, ranging from steaming to conventional baking. Its digital interface simplifies the cooking process, making it easy for users to navigate settings and timers, ensuring that meals are cooked to perfection every time.

The Kenmore 153.33955 is distinguished by its smart technology integration. This model can be controlled remotely via a smartphone app, providing the convenience of monitoring cooking from anywhere in the home. Users can set cooking times, adjust temperatures, and receive notifications when the food is ready, merging traditional cooking wisdom with modern technological advancements.

Model 153.339473 offers an enhanced safety profile, featuring automatic shut-off functions and child lock settings. This ensures peace of mind for families, particularly those with young children. The durable construction and high-quality materials used in this model further enhance safety and reliability, making it a top choice for parents.

Lastly, the Kenmore 153.339372 is engineered with sustainability in mind. It incorporates eco-friendly materials and processes, reducing its environmental footprint without compromising on performance. This model also features an intuitive energy-saving mode, which encourages users to optimize cooking habits and reduce waste.

Together, these Kenmore models exemplify the brand's commitment to innovation, safety, and environmental consciousness, catering to diverse consumer needs while ensuring quality and reliability in every use. With Kenmore, customers can trust that they are investing in products designed to enhance their daily lives.