Kenmore 153.33946 Recovery, Dimensions, Type Rategals, Diameter, BDJ Perhour Inches Heightto

Page 5

ThankYou for purchasing a Kenmore water heater. Propedy installed and maintained, it should give you years of trouble free service. If you should decide that you want the new water heater professionally installed by Sears call 1-800-4-MY-HOME ®. They will arrange for prompt, quality installation by Sears authorized contractors.

Abbreviations Found In This Instruction Manual:

CSA - Canadian Standards Association ANSI - American National Standards Institute NFPA- National Fire Protection Association ASME - American Society of Mechanical Engineers GAMA - Gas Appliance Manufacturers Association

This gas-fired water heater is design certified by CSA INTERNATIONAL under American National Standard/CSA

Standard for Gas Water Heaters ANSI Z21.10.1 CSA 4.1 (current edition).

Read the "Safety Precautions" section, page 3 of this manual first and then the entire manual carefully. If you don'tfollow the safety rules, the water heater will not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.

This manual contains instructions for the installation, operation, and maintenance of the gas-fired water heater. It also contains warnings through out the manual that you must read and be aware of. All warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few

pages, READ THE ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.

The installation must conform with these instructions and

the local code authority having jurisdiction. In the absence of local codes, installations shall comply with the following:

In the United States: The National Fuel Gas Code ANSI Z223.1/NFPA 54. This publication is available from the Canadian Standards Association, 8501 East Pleasant Valley Rd, Cleveland Ohio 44131, or The National Fire Protection Association, 1 Batterymarch Park, Quincy, MA 02269.

If after reading this manual you have any questions or do not

understand any portion of the instructions, call the Sears Service Center.

Carefully plan the place where you are going to put the water heater. Correct combustion, vent action, and vent pipe installation are very important in preventing death from possible carbon monoxide poisoning and fires. See figure 1.

Examine the location to ensure the water heater complies with the Facts to Consider About the Location section in this

manual.

For California installation this water heater must be braced, anchored, or strapped to avoid falling or moving during an

earthquake. See instructions for correct installation procedures. Instructions may be obtained from your local dealer, wholesaler, public utilities or California Office of the State Architect, 400 P Street, Sacramento, CA 95814.

. Massachusetts Code requires this water heater to be installed in accordance with Massachusetts 248-CMR 2.00: State Plumbing Code and 248-CMR 5.00.

Complies with SCAQMD rule #1121 and districts having equivalent NOx requirements.

 

 

 

 

RECOVERY

MINIMUM

 

 

DIMENSIONS

 

TANK

TYPE

 

RATEGALS.

VENT PIPE

DIAMETER

IN INCHES(mm)

 

CAPACITY

OF

B'DJ

PERHOUR

INCHES

 

INCHES

HEIGHTTO

MODELNUMBER

IN GALS (LTRS)

GAS

RATE

@ 90°F RISE

(mm)

 

(mm)

JACKET TOP

153.339210 HA

40 (151)

NATURAL

40,000

40.9

3" (76) or

4" (102)

20

1/4" (514)

47

1/4" (1,200)

153.339260

40 (151)

NATURAL

40,000

40.9

3" (76) or

4" (102)

20

1/4 "(514)

47

1/4" (1,200)

153.339360

30 (114)

NATURAL

40,000

40.9

3" (76) or

4" (102)

15 3/4" (400)

57

1/2" (1,461)

153.339410 HA

40 (151)

NATURAL

40,000

40.9

3" (76) or

4" (102)

18

1/4" (464)

55

1/2" (1,410)

153.339460

40 (151)

NATURAL

40,000

40.9

3" (76) or

4" (102)

18

1/4" (464)

55

1/2" (1,410)

153.339511 HA

50 (189)

NATURAL

40,000

40.9

3" (76) or

4" (102)

20

1/4" (514)

56

1/2" (1,435)

153.339560

50 (189)

NATURAL

40,000

40.9

3" (76) or

4" (102)

20

1/4" (514)

56

1/2" (1,435)

153.339760

50 (189)

NATURAL

52,500

53.7

4" (102)

20

1/4" (514)

56

1/4" (1,429)

153.339960

40 (151)

PROPANE

37,000

37.8

3" (76) or

4" (102)

18

1/4" (464)

55

1/2" (1,410)

Image 5
Contents Sears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A Installation and service must beDo not store or use gasoline or other Model noIndicates An imminently Symbol indicates a potentially hazardousCould result in death or injury Death or injuryFire Hazard Improper installation and use may result Property damageExplosion Hazard Feel water before bathing or showeringPage Dimensions RecoveryType Rategals DiameterMaterials Needed When Sweat SolderingBasic Tools Additional Tools Needed You may or may not need all these tools, depending on yourManuaIGas Shut-off Valve AnodeThermostat Pilot & Main BurnerTurn OFF the gas supply to Water Heater Removing the Old Water HeaterFire or ExpJosion Hazard Facts to Consider About LocationProperty Damage Hazard Ii ,i Insulation BlanketsFIGUREll ALL AIR from Inside BuildingsHotter Water can Scald Water PipingWater Damage Hazard Temperature-Pressure Relief ValveVenting Filling the Water HeaterFire and Explosion Hazard Gas PipingIre and Explosion Hazard Sediment TrapsGAS Piping with ALL Black Iron Pipe to GAS Control What to do if YOU Smell GAS RreOsoTemperature Regulation Burner Cleaning Tank Sediment Cleaning Burner InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingSee Figure Drain Valve Washer ReplacementService Inlet* Water Heater Capacity Ganons Pressure Start Up ConditionsThermal Expansion Operational Conditions MakenecessaryairsupplychangestocorrectILII/I Leaking T&P Valve Page Page Model Numbers Part Description BurnerassemblyBy calling 1-800-366-PART 1-800-366-7278. If the parts you 153.339560 153.339760Information Page Limited Warranty on Tanks That Leak Full ONE Year Warranty on Water HeaterLimited Warranty on Parts Sears Installation Service