Tank (Sediment) Cleaning | Burner Inspection |
Sediment
Service Center. For ordering, refer to the Parts Order List section.
Vent System Inspection
!'lvivf_r,t,l II
Carbon Monoxide and Fire Hazard
•Flue gases may escape if vent pipe is not connected.
•Be alert for obstructed, sooted or deteriorated vent system to avoid serious injury or death.
•Do not store corrosive chemicals in vicinity of water heater.
system can cause serious injury or
i• Chemical corrosion of flue and vent death
Breathing carbon monoxide can cause brain damage or death Always read and understand instruction manual
At least once a year a visual inspection should be made of the venting system. You should look for:
•Obstructions which could cause improper venting. The combustion and ventilation air flow must not be obstructed.
•Damage or deterioration which could cause improper venting or leakage of combustion products.
•Rusted flakes around top of water heater.
Be sure the vent piping is properly connected to prevent escape of dangerous flue gasses which could cause deadly asphyxiation.
Obstructions and deteriorated vent systems may present serious health risk or asphyxiation.
Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.
If when inspecting the vent system you find sooting or deterioration, something is wrong. Call the local gas supplier to correct the problem and clean or replace the flue and venting before resuming operation of the water heater.
Flood damage to a water heater may not be readily visible or immediately detectable. However, over a period of time a flooded water heater will create dangerous conditions which can cause DEATH, SERIOUS BODILY INJURY, OR PROPERTY DAMAGE. Contact a Sears Service Center to replace a flooded water heater. Do not attempt to repair the unit! It must be replaced!
At least once a year a visual inspection should be made of the main burner and pilot burner. See Figure 23.
You should check for sooting. Soot is not normal and will impair proper combustion.
Soot
FIGURE23.
Burner Cleaning
Fire or Explosion Hazard
Failure to properly reseal the combustion chamber will disable the flammable vapor _gnition resistance feature of this water heater, which could result in death or serious njury Contact your local Sears Service Center for assistance
Read instruction manual before _._
installing, using or servicing ._ water heater
In the event your burner needs cleaning, following these instructions:
If inspection of the burner shows that cleaning is required, turn the gas control knob clockwise ( f% ) to the "OFF" position, depressing slightly.
NOTE: The knob cannot be turned from "PILOT" to "OFF" unless knob is depressed slightly. DO NOT FORCE.
The burner needs to be removed for cleaning. Call the Sears Service Center to remove and clean the burner and correct the
problem that required the burner to be cleaned.
2O