ThankYouforpurchasingSearswaterheaterProperly. instalbdandmaintained,it shouldgiveyouyearsoftrouble freeserviceItisstronglysuggestedthatthisnewwaterheater. beprofessionallyinstalled,contactthelocalSearsService CenteroranySearsstoreTheywillarrangeforprompt,quality. installationbySearsauthorizedcontractors.
AbbreviationsFoundInThis{nstructionManual:
UL= UnderwritersLaboratoriesInc,
NEC= National Electrical Code
ANSI = American National Standards Institute
Read the "General Safety" section, page 3 of this manual first and then the entire manual carefully. If you don't follow the safety rules, the water heater wil! not operate properly. It could cause DEATH, SERIOUS BODILY INJURY AND/OR PROPERTY DAMAGE.
This manual contains instructions for the installation,
operation, and maintenance of this ebctric water heater. It also contains warnings throughout the manual that you must read and be aware of. Ai! warnings and all instructions are essential to the proper operation of the water heater and your safety. Since we cannot put everything on the first few
pages, READ THIS ENTIRE MANUAL BEFORE ATTEMPTING TO INSTALL OR OPERATE THE WATER HEATER.
The installation must conform with the instructions in this manual; electric company rules; and Local Codes, or in the
absence of Local Codes, with the current edition of the NEC o National Electrical Code, NFPA 70. This publication
is availabb from your local government or public library or
electric company or by writing Underwriters Laboratories
Inc., 333 Pfingsten Road, Northbrook, IL 60062.
If after reading this manual you have any questions or do
not understand any portion of the instructions, call Sears Service Center.
Carefully plan the place where you are going to put the water
heater. Correct electrical wiring and connections are very important in preventing death from possible electrical shock and fires.
Examine the location to ensure the water heater complbs with the "Facts to Consider About the Location" section.
For California installation this water heater must be braced,
anchored, or strapped to avoid falling or moving during an
earthquake. See instructions for correct installation procedures.
Instructions may be obtained from the California Office of the
State Architect, 400 P Street, Sacramento, CA 95814.
Massachusetts Code requires this water heater to be installed
in accordance with Massachusetts 248oCMR 2.00; State
Plumbing Code and
Massachusetts, this product must be installed by a licensed plumber or gasfitter.
| TANK |
| DBMENSBONS |
|
| ELEMENT |
| MAXBMUM FUSE | |||||
|
| RECOVERY | RATE | WATTAGE | MINtMUM | OR qRCUr | |||||||
| CAPACITY |
| iN iNCHES (rnm) | ||||||||||
MODEL |
| GALS.PER | HOUR | @240 | VOLTS | WiRE SIZE* | BREAKER | ||||||
|
|
|
|
|
|
| |||||||
NUMBER | Gab | Liters | DBA. | HEIGHT | @90°F Rise | UPPER | LOWER | {GAUGE) | SiZE (AMPS} | ||||
|
|
|
|
|
|
|
| ||||||
153.329262 | 38 | 144 | 25 | (635) | 31.5 | (800) | 17.3 |
| 3800 | 3800 | 12 | 20 | |
153.329263 | 25.0 |
| 3800 | 5500 | 10 | 30 | |||||||
|
|
|
|
|
|
|
| ||||||
153.329360 | 30 | 114 | 19 (483) | 47 | (1,194) | 17.3 |
| 3800 | 3800 | 12 | 20 | ||
153.329361 | 25.0 |
| 3800 | 5500 | 10 | 30 | |||||||
|
|
|
|
|
|
|
| ||||||
153.329460 | 40 | 151 | 19 (483) | 60 | (1,524) | 17.3 |
| 3800 | 3800 | 12 | 20 | ||
153.329481 | 25.0 |
| 3800 | 5500 | 10 | 30 | |||||||
|
|
| |||||||||||
|
|
|
|
|
|
|
| ||||||
153.329560 | 55 | 208 | 21.5 | (546) | 61 | (1,549) | 17.3 |
| 3800 | 3800 | 12 | 20 | |
153.329561 | 25.0 |
| 3800 | 5500 | 10 | 30 | |||||||
|
|
| |||||||||||
|
|
|
|
|
|
|
| ||||||
153.329660 | 66 | 250 | 23 | (584) | 61 | (1,549) | 17.3 |
| 3800 | 3800 | 12 | 20 | |
153.329681 | 25.0 |
| 3800 | 5500 | 10 | 30 | |||||||
|
|
|
|
|
|
|
| ||||||
153.329880 | 80 | 303 | 25 | (635) | 61.5 |
| (1,562) | 173 |
| 3800 | 3800 | 12 | 20 |
153.329861 |
| 25.0 |
| 3800 | 5500 | 10 | 30 | ||||||
|
|
|
|
|
|
|
|
Wiring size based on standard 60°C copper wire. If distance from fuse box to water heater is more than 90 feet, refer to your local electrical code.