Kenmore 152.329361, 153.32956 Filling the Water Heater, Water Damage Hazard, Temperature Pressure

Page 11

Positionthevalvedownwardandprovidetubingsothatany Ifaftermanuallyoperatingthevalve,itfailstocompletelyreset dischargewillexitonlywithin6inches(153mm)above,orat andcontinuesto releasewater,immediatelyclosethecold anydistancebelowthestructuralfloorBecertainthatnocontact. waterinlettothewaterheater,followthedraininginstructions, ismadewithanyliveelectricalpart.Thedischargeopening andreplacethetemperature-pressurereliefvalvewitha new must not be blockedor reducedin size underany one.

circumstancesExcessivelength,over30feet(9..14m),oruse

ofmorethanfourelbowscancauserestrictionandreducetheCOLD

dischargecapacityofthevalve.

Water Damage Hazard

, Temperature-pressure relief valve discharge pipe must terminate at adequate drain.

TEMPERATURE-

/, PRESSURE

No valve or other obstruction is to be placed between the relief valve and the tank. Do not connect tubing directly to discharge

drain unless a 6 inch air gap is provide& To prevent bodily injury, hazard to life, or property damage, the relief valve must

be allowed to discharge water in quantities should

circumstances demand. If the discharge pipe is not connected to a drain or other suitable means, the water flow may cause property damage.

The Discharge Pipe:

*Shall not be smaller in size than the outlet pipe size of the valve, or have any reducing couplings or other restrictions.

Shall not be plugged or blocked.

*Shall be of material listed for hot water distribution.

Shall be installed so as to allow complete drainage of both

the temperature-pressure relief valve, and the discharge pipe.

, _/ REUEF VALVE

'_ D_SCHARGE PUPE

(DO NOT CAP OR PLUG)

O-

G" AiR GAP

FLOOR DRAIN

FIGURE 10.

Filling the Water Heater

*

Shall

terminate

at

an adequate

drain.

 

Property

Damage

Hazard

*

Shall

not have

any

valve between

the relief valve

and tank.

- Avoid water

heater

damage.

 

 

 

 

 

 

 

 

 

 

 

- Fill tank with

water

before

operating.

Water temperature over 125°F

(52°C) can cause severe burns instantly resulting in severe injury or death,

Children, the elderly, and the physically or mentally disabled are at highest riskfor scald iniury.

Feel water before bathing or showering,

Temperature limiting valves are available

Read instruction manual for safe temperature setting

The temperature-pressure relief valve must be manually operated at least once a year. Caution should be taken to ensure that (1) no one is in front of or around the outlet of the

temperature-pressure relief valve discharge line, and (2) the water manually discharged will not cause any bodily injury or property damage because the water may be extremely hot.

Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating element, the tank must be filled with waten Water must flow from the hot water faucet before turning 'ON" power.

To fill the water heater with water:

1.Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is located on the lower front of the water heater.

2.Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

3.To insure complete filling of the tank, allow air to exit by opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the water heater and the piping.

11

Image 11
Contents Save Tnbs Manual for Future Reference Sears, Roebuck and Co., Hoffman Estates, L 60179 U.S.AModel UstedPortant Definitions Fire Hazard / Electric Shock Hazard Improper installation and use may result Property damageExplosion Hazard Troubleshooting Guide Safe Installation Useand Service GeneralInstallation Instructions Service MaintenanceVolts Tank Dbmensbons Element Maxbmum Fuse Recovery Rate WattageCapacity Model GALS.PER HourBasic Toos Additiona Toos Needed When Sweat SoderingMaterials Needed Burn hazard Hotwater discharge Keep hands clear of drain Removing the Od Water HeaterFacts to Consider About Convertible Lower Eement IneraiBuilduporSediment MayAccumuiateFacts to Consider About the Location Nsuation BanketsWater Piping Do not CAP Or Plug HOTFLEXIBLESHUT-OFF Outlet Water ConnectorsvalveValve and Pipe insulation Floor Drain Temperature PressureFilling the Water Heater Water Damage HazardElectric Converting the Lower EementFire Hazard t Electric Shock Hazard Conversion Parts Screw?ERMBNAL Cover from Fire and Explosion HazardFire Hazard Electric Shock Hazard ReplacetheaccesspanelGreen Ground Screw Theconduitortubingisterminatedfittingsapproved forgroundingFor 5500 Watts Wiring DiagramsTo Electric Power Supply RED UpperThermostat Temperature RegulationTemperature Settings Upper and Lower Thermostat AdjustmentsDraining TurnOFFtheelectricpowertothewaterheaterat the junctionboxTemperature-Pressure Relief Valve Operation Anode Rod inspectionWithout High Limit Upper and Lower Thermostat with HGH Lmit Thermostat Removal/ReplacementEement CeaningiRepmacement UFT OUT TAB to UncupUpperand Lower Thermostat WTH High Limit Fire Hazard Electric Shock Hazard Drain Valve Washer Repmacement ServiceHandleand CAP Assembly Operationa Conditions Therma! Expansion Tank SpecificationsChart Start Up ConditionsRumbung Nose High Temperature Shut OFF SystemReset CorrosionprotectiveactionoftheanodeLeakage Checkpoints Mmproper installation and use may result Property damageInstructions section Kenmore Power Miser TM Electric Water Heaters 153.329360 Gallon 153.329460 153.329560 KENtvIOREPOWER Miser TMWhen ORDERmNGREPAIR PARTS,ALWAYSGIVETHE Following Page Page Master Protection Agreements Warranty ServiceMY-HOM