NOTE:Toprotectagainstuntimelycorrosionofhotandcored waterfittings,it is stronglyrecommendedthatdioemectric unionsorcouplingsbeinstalledor}thiswaterheaterwhen connectedtocopperpipe.
1.LookatthetopcoverofthewaterheaterThehotwateroutlet.
ismarkedhot.Puttwoorthreeturnsofteflontapearound thethreadedendof
2.LookatthetopcoverofthewaterheaterThecoldwaterinlet.
ismarkedcoldPuttwoorthreeturnsofteflontapearound. thethreadedendof
aroundbothends of the 3/4" threaded nipple. Using flexible
connectors, connect the cold water pipe to the cold water inlet of the water heater.
NOTE: Your water heater is insulated to minimize heat loss
from the tank. Further reduction in heat Boss can be
accomplished by insu[ating the hot water lines from the water heater.
HOTFLEXIBLESHUT-OFF
OUTLET WATER CONNECTORSVALVE
TO
FitT&PvalveinsulationovervalveMakesurethattheinsulation.
doesnotinterferewiththeleveroftheT&Pvalve.
Secureallinsulationusingtape.
PiPE
iNSULATION
i
iNSULATION \i\_J
FIGURE gA.
Temperature-Pressure Relief Valve
HOUSE |
| [_ |
l |
| COLD |
|
| INLET |
THREADED | THREADED | WATER |
TO SWEAT | TO SWEAT | UNE |
COUPLING | COUPLING |
|
PRESSURE
REUEF VALVE /"
DISCHARGE
Explosion Hazard
,
must comply with ANSI A21.22 and ASME code.
"Properly sized
,Can result in overheating and excessive tank pressure
"Can cause serious iniury or death.
This heater is provided with a properly certified combination
temperature - pressure relief valve by the manufacturer.
(DO NOT CAP
OR PLUG}
FIGUREg.
T & P Valve and Pipe insulation
Remove insulation for T & P valve and pipe connections from carton.
Fit pipe insulation over the incoming cold water line and the hot
water line. Make sure that the insulation is against the top cover of the heater.
The valve is certified by a nationally recognized testing
laboratory that maintains periodic inspection of production of
listed equipment of materials as meeting the requirements for Relief Valves and Automatic Gas
Supply Systems, ANSI Z21.22 • CSA 4.4, and the code
requirements of ASME.
If replaced, the valve must meet the requirements of local
codes, but not less than a combination temperature and
pressure relief valve certified as indicated in the above paragraph.
The valve must be marked with a maximum set pressure not to exceed the marked hydrostatic working pressure of the water heater (150 psi = 1,035 kPa) and a discharge capacity not less than the water heater input rate as shown on the model rating plate.
For safe operation of the water heater, the relief valve must not be removed from its designated opening nor plugged.
The