Due to the nature of the typical gas water heater, the water temperature in certain situations may vary up to 30F ° (16.7 C °) higher or lower at the point of use such as, bathtubs, showers, sink, etc.

Any water heater's intended purpose is to heat water. Hot water is needed for cleansing, cleaning, and sanitizing (bodies, dishes, clothing). Untempered hot water can present a scald hazard. Depending on the time element, and the people involved (adults, children, elderly, infirm, etc.) scalding may occur at different temperatures.

Water temperature over 125°F (52°0) can cause severe burns

instantly resulting in severe injury or death.

Children, the elderly and the physically or mentally disabled are at highest risk for scald injury

Fee] water before bathing or showering.

Temperature limiting valves are available

Read instruction manual for safe temperature setting

HOTTER WATER CAN SCALD: Water heaters are intended to

produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly,

changing the factory setting on the thermostat, read the Temperature Regulation section in this manual, see Figures 21 and 22.

Never allow small children to use a hot water tap, or to draw their own bath water. Never leave a child or handicapped person unattended in a bathtub or shower.

NOTE: A water temperature range of 120°F-140°F (49°C-60°C) is recommended by most dishwasher manufacturers.

The thermostat of this water heater has been factory set at its lowest position. It is adjustable and must be reset to the desired temperature setting to reduce the risk of scald injury. The mark (A) indicative of approximately 120°F (49°0) is preferred starting point. Some states have a requirement for a lower setting.

Turn the water temperature dial clockwise ( t'_ ) to decrease the temperature, or counterclockwise ( _ ) to increase the temperature.

Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance.

GAS CONTROL KNOB

IGNITOR

GENERATOR

_iPIEZO

THERMOSTAT

DIAL

FIGURE21.

children, the infirm, or physically/mentally handicapped, if anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that satisfies your hot water needs, a means such as a mixing valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores. Follow manufacturer's instructions for installation of the valves. Before

VERY HOT= apl:_OX1600F(71°C).

C = approx. 150°F (66°0)

B = approx, 140°F (60°C)

A = approx. 130°F (5400)

= approx. 1200F (4900) LOW = approx, 80°F (27°C)

FIGURE 22.

About 1/2 second about 1-1/2 seconds Less than 5 seconds

About 30 seconds More than 5 minutes

19

Image 19
Contents Installation and service must be Safety InstructionInstallation Care Maintenance Troubleshooting Parts ListImportant Definitions Feel water before bathing or showering Improper installation and use may result Property damageRiskoffire Explosion HazardMatedal Needed Basic Water Piping 12-13 TemperatureLighting Operating Label Temperature Regulation Tank Sediment Cleaning Venting System InspectionVentpipe Diameter RecoveryDimensions Tank TypeMaterials Needed Additional Tools Needed When Sweat SolderingBasic Tools ALL Piping Materialsto be Suppliedby Customers ThermostatPilot & Main Burner FURE2 Removing the Old Water HeaterFKURE5 Fire Hazard Facts to Consider About LocationDoor FURE9 Insulation BlanketsALL AIR from Outdoors See Figures 9, 11,12 ALL AIR from Inside BuildingsProperty Damage Hazard Water PipingInstallation Completed Using Temperature-Pressure Relief ValveWater Damage Hazard Breathing Hazard Carbon Monoxide Gas Filling the Water HeaterVenting Property Damage HazardFire and Explosion Hazard Gas PipingFire and Explosion Hazard Sediment TrapsGAS Piping with ALL Black Iron Pipeto GAS Control GAS Control For Your Safety Read Before LightingTemperature Regulation Carbon Monoxide and Fire Hazard Tank Sediment Cleaning Burner InspectionBurner Cleaning Vent System InspectionDraining Temperature-Pressure Relief Valve OperationHousekeeping Anode Rod InspectionService Drain Valve Washer ReplacementSee Figure Strange Sounds Thermal Expansion Tank SpecificationsExpansion Tank Sizing Chart Start Up ConditionsAIR In Hot Water Faucets High Temperature Shut Off SystemCondensation Smoke OdorFURE27 Operational Conditions Leakage CheckpointsStay LIT Pilot Outage Model Numbers Key No. Part Description Burner AssemblyLimited Warranty on Tanks That Leak Full ONE Year Warranty on Water HeaterSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A

153.333315 HA, 153.333445, 153.333415 HA, 153.333545, 153.333345 specifications

The Kenmore 153.333345, 153.333545, 153.333445, 153.333315 HA, and 153.333415 HA air conditioning units represent a diversified range of solutions for both residential and commercial climate control needs. These models are specifically designed to meet the varying requirements of different environments, making them excellent choices for effectively managing indoor temperatures.

One of the main features of these Kenmore models is their advanced energy efficiency. Each unit is equipped with Energy Star certification, ensuring that they consume less electricity compared to standard models. This not only helps consumers save on energy bills but also contributes to environmental sustainability by reducing greenhouse gas emissions.

The cooling capacity of these units is tailored to fit spaces of various sizes. With BTU ratings that range across the different models, users can find an appropriate solution whether they require cooling for a small room or a more expansive area. Additionally, the inclusion of variable speed compressors allows for precise temperature control and improved humidity management, providing enhanced comfort without excessive energy expenditure.

Technologically, these models incorporate modern smart features that make user interaction seamless. Many of the Kenmore units can be controlled via smartphone apps and are compatible with smart home systems. This connectivity allows users to adjust settings, set schedules, and even monitor energy usage remotely.

The design of the Kenmore air conditioners emphasizes ease of installation and maintenance. Their lightweight construction permits simpler setups, while detachable filters ensure that air quality remains high by allowing for easy cleaning and replacement. Moreover, the units feature robust build quality, designed to withstand the rigors of daily use over many years.

In terms of noise levels, Kenmore has prioritized quiet operation. These air conditioners are engineered to operate at lower decibel levels, meaning that they can be used in bedrooms or quiet office spaces without causing disturbances.

In summary, the Kenmore 153.333345, 153.333545, 153.333445, 153.333315 HA, and 153.333415 HA air conditioning units present a blend of energy efficiency, advanced technology, ease of use, and reliability. These features make them excellent choices for anyone looking to optimize indoor comfort while minimizing energy impact.