Kenmore 153.333415 HA, 153.333345 Thermostat, ALL Piping Materialsto be Suppliedby Customers

Page 7

GET TO KNOW YOUR WATER HEATER - GAS MODELS

A

Vent

Pipe

 

J

Drip

Leg (Sediment

Trap)

S

Flue Baffle

 

B

Draft

Hood

 

K

Inner

Door

 

T

Thermostat

 

C

Anode

 

L

Outer

door

 

U

Drain Valve

 

D

Hot Water

Outlet

M

Union

 

V

Pilot and Main Burner

E

Outlet

 

N

Inlet

Water Shut-off Valve

W

Flue

 

F

Flexible Water Connections

O

Cold

Water Inlet

 

X

Drain Pan

 

G

Gas Supply

 

P

Inlet Dip Tube

 

Y

Thermostat

Shield optional)

H

ManuaIGas

Shut-off Valve

Q

Temperature-Pressure

Relief Valve

Z

Piezo Ignitor

I

Ground Joint Union

R

Rating Plate

 

AA

Air Intake

Screen

*INSTALL IN ACCORDANCE WITH LOCAL CODES.

*DRIP LEG AS REQUIRED BY LOCAL CODES.

TO VENT TERMINATION

ON ROOF

INSTALL THERMAL EXPANSION

TANK IF WATER HEATER

IS INSTALLED IN A CLOSED

WATER SYSTEM

(T) THERMOSTAT

GAS CONTROL KNOB

B

VACUUM RELIEF

VALVE

_]N_TALLPER LOCALCODE5

Q

S

W

V

Y

AA

*ALL PIPING MATERIALSTO BE SUPPLIEDBY CUSTOMERS.

FIGURE1.

I

WATER TEMPERATURE

{ADJUSTING DIAL)

"OFF ....PILOT .... ON"

POSITIONPOSITION POSITION

TOP VIEW

(V) PILOT & MAIN BURNER

BURNER TUBE

/

MAIN BURNER

THERMOCOUPLE

 

/

--_ IGNITOR ROD

 

 

\

PILOT TUBING

/

PILOT BURNER

[

THERMOCOUPLE

TgO

7

Image 7
Contents Installation and service must be Safety InstructionInstallation Care Maintenance Troubleshooting Parts ListImportant Definitions Feel water before bathing or showering Improper installation and use may result Property damageRiskoffire Explosion HazardMatedal Needed Basic Water Piping 12-13 TemperatureLighting Operating Label Temperature Regulation Tank Sediment Cleaning Venting System InspectionVentpipe Diameter RecoveryDimensions Tank TypeMaterials Needed Additional Tools Needed When Sweat SolderingBasic Tools ALL Piping Materialsto be Suppliedby Customers ThermostatPilot & Main Burner FURE2 Removing the Old Water HeaterFKURE5 Fire Hazard Facts to Consider About LocationDoor FURE9 Insulation BlanketsALL AIR from Outdoors See Figures 9, 11,12 ALL AIR from Inside BuildingsProperty Damage Hazard Water PipingInstallation Completed Using Temperature-Pressure Relief ValveWater Damage Hazard Breathing Hazard Carbon Monoxide Gas Filling the Water HeaterVenting Property Damage HazardFire and Explosion Hazard Gas PipingFire and Explosion Hazard Sediment TrapsGAS Piping with ALL Black Iron Pipeto GAS Control GAS Control For Your Safety Read Before LightingTemperature Regulation Carbon Monoxide and Fire Hazard Tank Sediment Cleaning Burner InspectionBurner Cleaning Vent System InspectionDraining Temperature-Pressure Relief Valve OperationHousekeeping Anode Rod InspectionService Drain Valve Washer ReplacementSee Figure Strange Sounds Thermal Expansion Tank SpecificationsExpansion Tank Sizing Chart Start Up ConditionsAIR In Hot Water Faucets High Temperature Shut Off SystemCondensation Smoke OdorFURE27 Operational Conditions Leakage CheckpointsStay LIT Pilot Outage Model Numbers Key No. Part Description Burner AssemblyLimited Warranty on Tanks That Leak Full ONE Year Warranty on Water HeaterSears, Roebuck and Co., Hoffman Estates, IL 60179 U.S.A

153.333315 HA, 153.333445, 153.333415 HA, 153.333545, 153.333345 specifications

The Kenmore 153.333345, 153.333545, 153.333445, 153.333315 HA, and 153.333415 HA air conditioning units represent a diversified range of solutions for both residential and commercial climate control needs. These models are specifically designed to meet the varying requirements of different environments, making them excellent choices for effectively managing indoor temperatures.

One of the main features of these Kenmore models is their advanced energy efficiency. Each unit is equipped with Energy Star certification, ensuring that they consume less electricity compared to standard models. This not only helps consumers save on energy bills but also contributes to environmental sustainability by reducing greenhouse gas emissions.

The cooling capacity of these units is tailored to fit spaces of various sizes. With BTU ratings that range across the different models, users can find an appropriate solution whether they require cooling for a small room or a more expansive area. Additionally, the inclusion of variable speed compressors allows for precise temperature control and improved humidity management, providing enhanced comfort without excessive energy expenditure.

Technologically, these models incorporate modern smart features that make user interaction seamless. Many of the Kenmore units can be controlled via smartphone apps and are compatible with smart home systems. This connectivity allows users to adjust settings, set schedules, and even monitor energy usage remotely.

The design of the Kenmore air conditioners emphasizes ease of installation and maintenance. Their lightweight construction permits simpler setups, while detachable filters ensure that air quality remains high by allowing for easy cleaning and replacement. Moreover, the units feature robust build quality, designed to withstand the rigors of daily use over many years.

In terms of noise levels, Kenmore has prioritized quiet operation. These air conditioners are engineered to operate at lower decibel levels, meaning that they can be used in bedrooms or quiet office spaces without causing disturbances.

In summary, the Kenmore 153.333345, 153.333545, 153.333445, 153.333315 HA, and 153.333415 HA air conditioning units present a blend of energy efficiency, advanced technology, ease of use, and reliability. These features make them excellent choices for anyone looking to optimize indoor comfort while minimizing energy impact.