B)CLEANING THE FILTER
Clean the air filter once every two weeks to remove dust
Remove the filter: Pull out the filter cover and remove the air filter from the filter cover.
Cleaning: Wash the air filter by immersing it in lukewarm water with a mild detergent. Rinse the filter and dry it in a dark place. Do not put in direct sunlight.
Replace the filter: Attach the filter to the filter cover using the attachment hooks on the inner surface of the cover. Put the filter cover back to the unit.
C) CLEANING THE EXTERIOR
Moisten a soft cloth with mild detergent and water to wipe the unit clean. Be sure not to use a soaking wet cloth.
D) DRAINAGE/EXTENDED PERIOD OF NON-USE
If the air conditioner will not be used for a long period of time, remove the bottom rubber plug from the back hole and attach a section of the Continuous Drain Hose and completely drain the unit of water.
STORAGE
Follow cleaning instructions
Perform reverse Installation Instructions.
Repack the unit in its original package and store upright in a cool dry place.
Important: Always store and transport the air conditioner upright to maintain the compressor in a proper condition.
TECHNICAL SPECIFICATIONS
MODEL | 35132 |
VOLTAGE | 120V~60Hz |
POWER CONSUMPTION | 1400W |
COOLING | |
HEATING | 1200W |
COOLING CAPACITY | 12,000BTU/h |
HEATING CAPACITY | 12,000BTU/h |
DEHUMIDIFYING CAPACITY (30°C, RH80%) | 60L/Day |
NOISE LEVEL (Indoor use) | 53dB(A) |
AIR CIRCUALTION (m³/h) | 450 |
COOLING AGENT | R410A |
REMOTE CONTROL | INCLUDED |
TIMER | |
DIMENSIONS (WxDxH) | 30cmx50.5cmx77.8cm / 12”x20.2”x31.12” |
NET WEIGHT | 29.5 kg / 65Lbs |
13