Kenmore 35132 manual Compressor does not activate, Unit deactivates, Unit does not cool correctly

Page 15

 

 

areas). Run the unit for ½ a day. The smell

 

 

will disappear after a while. In the case of

 

 

intensive odor development air the room.

Compressor does not activate

 

Depending on ambient temperatures and

 

 

unit type it may take approx. 10 minutes

 

 

after starting the compressor until the

 

 

cooling/heating capacity is reached.

The unit deactivates

 

On reaching the set required temperature,

 

 

the unit switches off automatically. Check

 

 

manual setting of the required temperature

 

 

as well as the TIMER setting.

The unit does not cool correctly

 

You achieve the most effective and

 

 

economical cooling comfort if you already

 

 

cool the room to be cooled when the room

 

 

temperature is not yet heated up. Air

 

 

conditioners operate more effectively if the

 

 

temperature is maintained. To drastically

 

 

cool the air in a fully heated room requires

 

 

much more time and energy.

ERROR CODES

 

 

 

 

 

E1

Room temperature outside the

Observe all data in these operating

 

function range:

instructions concerning function range.

 

 

Temporary error of start temperature.

 

Room temperature inside the

Please switch the unit off and start it again

 

function range:

after approx. 30 minutes. If the error

 

 

occurs continuously, the unit requires

 

 

qualified inspection.

E2

Temperature of the cooling

Temporary error on measuring output

 

agent lines too high or too low

temperature. Please switch the

 

 

TRANSFORM unit off and start it again

 

 

after approx. 30 minutes. If the error

 

 

occurs continuously, the unit requires

 

 

qualified inspection.

E3

Incorrect signal

This error message in the cooling function

 

 

refers to too high ambient temperatures

 

 

and in the heating function to too low

 

 

ambient temperatures. Please observe the

 

 

instructions relating to ideal operation of

 

 

the unit. This may also be a temporary

 

 

error measurement between the start and

 

 

output temperature. Please switch the unit

 

 

off and start it again after approx. 30

 

 

minutes. If the error occurs continuously, the

 

 

unit requires qualified inspection.

E4

Water tank full

If the water tank is full, the warning sign

 

 

"E4" appears in the display. To restart

 

 

operation of the unit, please remove the

 

 

plug of the condensation water outlet to

 

 

allow water to leak out. Please use an

 

 

appropriate collection tank. When the

 

 

water has been completely removed,

 

 

please start the unit again. The unit can

 

 

now be used as usual.

DF

De-icing mode

This procedure is completely normal and

 

 

protects the system from icing and failure.

 

 

The unit starts automatically after approx.

 

 

15 minutes again (depending on the

 

 

function setting). This procedure repeats

 

 

itself regularly.

15

Image 15
Contents For Household USE only KenmoreImportant Safeguards Page Unpacking Instructions Location of the Portable AIR Conditioner Figure Window KIT InstallationTo Test the Safety Plug Safety PlugPower TEMP+LED-DISPLAY How to program a delayed start up How to program a delayed shutdownSpeed Remote Control Operating Instructions Reciever Installation Heating Mode ***UNIT Must be Used in Room for Heat ModeCleaning & Maintenance Power Consumption Cleaning the FilterCan I turn the unit on immediately Unit does not start when pressingPower button When turning the unit on I sense aUnit does not cool correctly Error CodesCompressor does not activate Unit deactivatesWarranty Period