Kenmore 153.316454 Installation Instructions contd, Facts to Consider About the Location

Page 7

Installation Instructions (cont'd)

Facts to Consider About the Location

You should carefully choose an indoor location for the new water heater, because the placement is a very important consideration for the safety of the occupants in the building and for the most

economical use of the appliance. This water heater is not intend- ed for outdoor installation.

Whether replacing an old water heater or putting the water heater in a new location, the following critical points must be observed.

The location selected should be indoors as close to and as cen-

tralized with the water piping system as possible. This water heater, as well as all water heaters, will eventually leak. Do not

install without adequate drainage provisions where water flow will cause damage.

_CAUTION

WATER HEATERS EVENTUALLY LEAK: Installation of

the water heater must be accomplished in such a man- ner that if the tank or any connections should leak, the flow of water will not cause damage to the structure. When such locations cannot be avoided, a suitable drain pan should be installed under the water heater. Drain pansare available at your local Sears stores.Such a drain

pan must be piped to an adequate drain. Under no cir- cumstances is the manufacturer or Sears to be held

liable for any water damage in connection with this water heater.

Facts to Consider About the Convertible Lower Element

The Upper Element (if a double element model), is a conven- tional 3800 watt element which only operates at its rated wattage on 240 volts. (See rating plate on water heater).

The Lower Element of the water heater can be converted from operation at 3800 watts to 5500 watts on a 240 volt system.

Read and follow water heater warnings and instructions.If after

reading these instructions in this manual, if you do not under- stand any portion, call Sears Service Center.

A, WARNING

Before making the conversion to 5500 watts, check the

(I)power supply...must be 240 volts, (2) wiring...10 gauge AWG, Type TW, 60°C or equivalent, and (3)

Circuit breakers or fusing...capable of 30 amp loading. Also, the installation must conform with this manual,

local codes and electric utility rules. Failure to comply can result in DEATH, SERIOUS BODILY INJURY, OR

PROPERTY DAMAGE.

&CAUTION

INSTALLATION IN RESIDENTIAL GARAGES: The water beater must be located and/or protected so it is

not subjectto physca damage by a mov ng veh c e.

The location selection must provide adequate clearances for servicing and proper operation of the water heater.

NOTE: Whether or not the element conversion is made the

model rating plate must be marked. Using a hardpoint ink pen, check the appropriate block within the model rating plate, which is located adjacent to the lower access panel.

Image 7
Contents Owners Read the General Safety Section Beginning on Inside CoverOUS BOD LY NJURY,OR Property Damage Safety PrecautionsContents Preparing for the New Installation Product SpecificationsCustomer Responsibilities Basic Tools Materials and Basic Tools NeededRemoving the Old Water Heater Installation InstructionsProperty Damage Installation Instructions contdFacts to Consider About the Location Facts to Consider About the Convertible Lower ElementWater Piping Installation completed Using Sears KitContd Temperature-Pressure Relief ValveConverting the Lower Element Filling the Water HeaterResult in DEATH, Serious Bodily Injury or Property Damage Converting the Lower Element contd Converting the Lower Element contd Installation Instructions contdHeatingelement Wiring DiagramsWiring Model Rating Plate Installation ChecklistThermostats Service and AdjustmentTemperature Regulation Temperature SettingsDraining Service AdjustmentLower Thermostat Adjustment Temperature-Pressure ReliefElement Cleaning Replacement Service and Adjustment contdTerminal Awarning ServiceStrange Sounds Troubleshooting GuideStart Conditions Thermal ExpansionAIR in HOT Water Faucets High Temperature Shut OFF SystemHigh Temperature Shut OFF System Not Enough Or no HOT Water Troubleshooting Guide contdWater is TOO HOT INJURY,OR Property Damage Leakage CheckpointsPage Element Ordering Information Parts Order List153.316153 30 GM. Sho 153.316252 40Gal. Sho Parts Order List contdParts Order List Model Number Name of Part Part Number Element Ordering Information Kenmore Power Miser TM 6 Electric Water Heaters About Your Warranty WarrantySears Installation Warranty Sears Installation Policy