Service and Adjustment (cont'd)

TERMINAL

COVER ON

UPPER

THERMOSTAT

7.Disconnect the two wires on the element and unscrew the old element from the tank.

8.Clean the area around the element opening. Remove any

sediment from or around the element opening and inside the tank.

9.If you are cleaning the element you have removed, do so by scraping or soaking in vinegar or a de-liming solution.

AWARNING

Replacement elements must (I) be the same voltage and

(2)no greater wattage than listed on the model rating p ate affixed to the water heater.

10.A new gasket should be used in all cases to prevent a possi- ble water leak. (See Element Gasket in the Parts Order List

Chart). Place the new element gasket on the thread side of the cleaned or new element and screw into tank, securing tightly using an element wrench.

11.Close the water heater drain valve by turning the handle to

the right (clockwise). The drain valve is on the lower front of the water heater.

12.Open the cold water supply valve to the water heater.

NOTE: The cold water supply valve must be left open when the water heater is in use.

13.To insure complete filling of the tank, allow air to exit by

opening the nearest hot water faucet. Allow water to run until a constant flow is obtained. This will let air out of the

water heater and the piping.

A CAUTION

Never use this water heater unless it is completely full of water. To prevent damage to the tank and heating ele- ment, the tank must be filled with water. Water must flow from the hot water faucet before turning "ON" power

14.Check element for water leaks. If leakage occurs, tighten element or repeat steps 2 and 3, remove element and reposi- tion gasket. Then repeat steps 10 through 14.

15.Reconnect the two wires to the element and then check to

make sure the thermostat remains firmly against the surface of the tank.

19

Image 19
Contents Owners Read the General Safety Section Beginning on Inside CoverOUS BOD LY NJURY,OR Property Damage Safety PrecautionsContents Preparing for the New Installation Product SpecificationsCustomer Responsibilities Basic Tools Materials and Basic Tools NeededRemoving the Old Water Heater Installation InstructionsProperty Damage Installation Instructions contdFacts to Consider About the Location Facts to Consider About the Convertible Lower ElementWater Piping Installation completed Using Sears KitContd Temperature-Pressure Relief ValveConverting the Lower Element Filling the Water HeaterResult in DEATH, Serious Bodily Injury or Property Damage Converting the Lower Element contd Converting the Lower Element contd Installation Instructions contdHeatingelement Wiring DiagramsWiring Model Rating Plate Installation ChecklistThermostats Service and AdjustmentTemperature Regulation Temperature SettingsDraining Service AdjustmentLower Thermostat Adjustment Temperature-Pressure ReliefElement Cleaning Replacement Service and Adjustment contdTerminal Awarning ServiceStrange Sounds Troubleshooting GuideStart Conditions Thermal ExpansionAIR in HOT Water Faucets High Temperature Shut OFF SystemHigh Temperature Shut OFF System Not Enough Or no HOT Water Troubleshooting Guide contdWater is TOO HOT INJURY,OR Property Damage Leakage CheckpointsPage Element Ordering Information Parts Order List153.316153 30 GM. Sho 153.316252 40Gal. Sho Parts Order List contdParts Order List Model Number Name of Part Part Number Element Ordering Information Kenmore Power Miser TM 6 Electric Water Heaters About Your Warranty WarrantySears Installation Warranty Sears Installation Policy