Kenmore 153.316655, 153.316554, 153.316555, 153.316455, 153.316754, 153.316355 Service, Awarning

Page 20

Service and Adjustment (cont'd)

Element Cleaning/

Replacement (cont'd)

16.Replace terminal cover on thermostat making sure that the locking tabs on the terminal cover are in place.

17.Replace the insulation block so that it completely covers the thermostat and element.

Drain Valve Washer

Replacement

NOTE: For replacement, use a *_2" x ,3/,, x ¼" thick washer

available at your nearest hardware store. For ordering a replacement washer, refer to the "Parts Order List" section.

Before beginning turn "OFF" the electrical power supply to the water heater.

AWARNING

HAZARD OF ELECTRICAL SHOCKI Before removing any access panels or servicing the water heater, make

sure the electrical supply to the water heater is turned "OFF". Failure to do this could result in DEATH, SERI-

OUS BODILY INJURY,OR PROPERTY DAMAGE.

Follow "Draining" instructions. See "Service and Adjustment" section.

18.Replace access panel.

19.Turn "ON" electric power to water heater.

Turning counter clockwise, remove the hex cap below the screw handle.

Remove the washer and put the new one in place.

Screw the handle and cap assembly back into the drain valve and retighten using a wrench. DO NOT OVER TIGHTEN.

Follow !'Filling the Water Heater" instructions in the "Installation Instructions" section.

Check for leaks.

Turn "ON" electric power to the water heater.

_ HANDLE AND

CAP ASSEMBLY

WASHER

Service

Before calling for repair service, read the Start Up Conditions

and Operational Conditions found in the Troubleshooting Guide of this manual.

If a condition persists or you are uncertain about the operation of the water heater, let a qualified person check it out.

Contact SEARS Repair Services at 1-800-4-MY-HOME

(1-800-469-4663).

20

Image 20
Contents Read the General Safety Section Beginning on Inside Cover OwnersSafety Precautions OUS BOD LY NJURY,OR Property DamageContents Customer Responsibilities Product SpecificationsPreparing for the New Installation Materials and Basic Tools Needed Basic ToolsInstallation Instructions Removing the Old Water HeaterInstallation Instructions contd Facts to Consider About the LocationFacts to Consider About the Convertible Lower Element Property DamageInstallation completed Using Sears Kit Water PipingTemperature-Pressure Relief Valve ContdResult in DEATH, Serious Bodily Injury or Property Damage Filling the Water HeaterConverting the Lower Element Converting the Lower Element contd Installation Instructions contd Converting the Lower Element contdWiring Diagrams HeatingelementWiring Installation Checklist Model Rating PlateService and Adjustment Temperature RegulationTemperature Settings ThermostatsService Adjustment Lower Thermostat AdjustmentTemperature-Pressure Relief DrainingService and Adjustment contd Element Cleaning ReplacementTerminal Service AwarningTroubleshooting Guide Start ConditionsThermal Expansion Strange SoundsHigh Temperature Shut OFF System AIR in HOT Water FaucetsWater is TOO HOT Troubleshooting Guide contdHigh Temperature Shut OFF System Not Enough Or no HOT Water Leakage Checkpoints INJURY,OR Property DamagePage Parts Order List Element Ordering InformationParts Order List contd 153.316153 30 GM. Sho 153.316252 40Gal. ShoParts Order List Model Number Name of Part Part Number Element Ordering Information Kenmore Power Miser TM 6 Electric Water Heaters Sears Installation Warranty Sears Installation Policy WarrantyAbout Your Warranty