2.After you complete the basic floor plan, make three cop- ies of it. Label each copy as being the plan for one of the three zone types (instant, delayed, and panic/tamper).

3.Decide what sensors and other parts you want to install and where, and mark them on the appropriate floor plan. Then draw a line connecting the sensors you want to assign to the labeled zone type on each copy. This will show how the sensors will be wired to each other and the alarm center.

For example, if you want to install a panic button in the bedroom and a tamper switch on a wall safe, on the Panic/Tamper floor plan, draw a loop connecting those

two sensors and ending at the location where you want to install the alarm center.

When you finish, these drawings will show the layout of each zone and the location of each sensor assigned to that zone.

Note: Since a violation of the panic/tamper zone immediate- ly sounds the alarm (even if the system is not armed), do not assign sensors protecting doors and windows to the panic/ tamper zone.

The different illustrations below show possible layouts for a home security system. Your floor plan will probably differ.

Instant Zone

 

 

Delayed Zone

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

BR1

Bath

BR2

BR3

Kitchen

Dining

LR

Garage

BR1

Bath

BR2

BR3

Kitchen

Dining

LR

Garage

Alarm Siren

Exterior Strobe

Alarm Center

Alarm Siren

Exterior Strobe

Alarm Center

Telephone JackPanic/Tamper Zone

Telephone Jack

AC Outlet

AC Outlet

BR1

Kitchen

 

 

Tamper Switches

Panic Buttons

Dining

Bath

BR2

 

 

LR

BR3

Garage

 

Telephone Jack

 

AC Outlet

 

Alarm Siren

Exterior Strobe

Alarm Center

Preparation

5

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 5
Contents Two-Zone Burglar Alarm System REQUIRED/OPTIONAL Accessories ˆ FeaturesSupplied Items Important NotesPower GND DATA2 Annc ˆ a Quick Look at Your Alarm Center/KeypadUnderstanding the System ˆ PreparationUnderstanding Zones Planning Your Security SystemInstant Zone Delayed Zone Room/Area Door Window Sensor Sounder Other System Planning WorksheetOther Ways to Improve Security Safeguarding Planning RecordsMaking a Shopping List Securing Your Home or OfficeNumber Model Serial No Value Insured Y/N Where/How Marked Property Inventory ListChoosing a Location for the Alarm Center Setting UP the SystemUsing the Tamper Switches Mounting the Alarm CenterSensors Choosing the ComponentsChoosing a Location for the Remote Keypad Automatic Telephone Dialer Sirens and LightsSystem Wiring Connections ˆ InstallationConnecting Remote Keypads Mounting the KeypadSetting the Keypad’s Address Connecting Sensors Into LoopsConnecting Loops of Sensors to the Alarm Center Jumpers on Normally-Closed TerminalsConnecting and Powering a Remote Security Device Connecting a PRE-ALARM BuzzerConnecting a Siren AND/OR Lights Connecting AC PowerFm Page 15 Wednesday, January 17, 2001 1037 AM Changing the Password Sounding a Panic Alarmˆ Operation Arming the SystemUsing Annunciate Mode ˆ Testing the SystemSetting the Entry and Exit Delay System ResetWeekly System Check Testing the Siren AND/OR LightsChecking the Indicators Replacing the Fuse Resetting the AC ADAPTER’S Circuit Breakerˆ Care Limited Ninety-Day Warranty ˆ Specifications

Two-Zone Burglar Alarm System specifications

The Radio Shack Two-Zone Burglar Alarm System is designed to provide homeowners and small business owners with effective security solutions. This system offers an excellent balance of functionality, reliability, and affordability, making it a popular choice for those looking to enhance their property's safety.

One of the standout features of the Radio Shack Two-Zone Burglar Alarm System is its dual-zone capability. This allows users to monitor multiple areas of their property separately. For example, one zone can be designated for exterior doors, while another can monitor interior spaces, which can help to prevent false alarms triggered by pets or other movements within the home. This feature is particularly useful for larger properties that require more than just a single-point monitoring system.

The system is equipped with multiple sensors, including door and window contacts, which can easily be installed to ensure comprehensive coverage. These sensors are designed to detect unauthorized entry and trigger the alarm whenever a door or window is opened. The system also includes passive infrared motion sensors that can identify movement within a designated area, adding an additional layer of security against intruders.

In terms of technologies, the Radio Shack Two-Zone Burglar Alarm System utilizes a microprocessor-controlled control panel, which is at the heart of the system's operations. This logic board processes signals from all connected sensors and determines when to trigger the alarm. The system can provide alerts via a loud siren, while also allowing for notifications to be sent to the owner’s smartphone or other devices, depending on the model.

The installation process for the Radio Shack burglar alarm system is user-friendly, designed for ease even for those who may not be technically savvy. The system typically includes clear instructions and mounting hardware, making setup straightforward. Users can customize their alarm system according to their specific needs and property layout, which further enhances usability.

Another important characteristic of the Radio Shack Two-Zone Burglar Alarm System is the option for battery backup. This ensures that the alarm continues to operate even during power outages, allowing for uninterrupted security coverage. Moreover, the system is frequently praised for its durability and resistance to environmental factors, making it a robust choice for various settings.

Overall, the Radio Shack Two-Zone Burglar Alarm System represents a practical and efficient security solution, combining essential features, advanced technology, and user-friendly installation, all designed to meet the security needs of modern users.