Radio Shack Two-Zone Burglar Alarm System ˆ Operation, Arming the System, Disarming the System

Page 16

49-454.fm Page 16 Wednesday, January 17, 2001 10:37 AM

Test the panic function of each installed remote keypad by holding down ENTER and CANCEL. The alarm center arms, ARMED blinks, and the lamp you connected to Terminals 15 and 16 (alarm siren and light) lights for 4 minutes.

12.Disarm the alarm system by entering 1 2 3 4, then hold down SETUP for 2 seconds. ARMED and READY flash slowly. Enter the password. ARMED and READY flash quickly. Press ANNC once. ARMED and READY turn off.

To enter announce mode, press ENTER. READY flashes 3 times. To exit announce mode, press CANCEL. READY flashes 3 times.

13.Hold down BATT TEST on the alarm center for 2 sec- onds. If BATT on the alarm center does not light, the backup battery is OK.

If BATT flashes:

Check the fuse on the alarm center. If it is blown, see “Replacing the Fuse” on Page 19 and repeat this step.

The backup battery might have insufficient power. Check the battery connections. If the connections are OK, the battery will be automatically recharged. If it does not recharge, replace it promptly.

14.Arm the alarm system by entering 1 2 3 4, then pressing ARM. Then disarm by entering the duress code, 1 2 3 5. The security dialer is triggered.

15.Use a flat-blade screwdriver to remove the screw from the center of the AC outlet and discard the screw. Then attach the AC adapter to AC outlet using the attached screw to secure it and discourage tampering.

16.Disconnect the lamp from Terminals 15 and 16, then connect the alarm siren’s and/or light’s negative (–) wire(s) to Terminal 15 and connect the positive (+) wire(s) to Terminal 16.

Your security system is ready to use!

ˆOperation

ARMING THE SYSTEM

To arm the system, use any connected keypad to enter the password then press ARM once, or simply press ARM twice.

If you enter the correct password and there are no activated or faulted zones, ARMED on the keypad lights, and the alarm system is armed. If you enter the wrong password, the sys- tem does not arm.

Notes:

While entering the password, if you enter an incorrect digit before entering the last digit, you can press CAN- CEL to cancel your previous entries, then enter the password again.

When you use a connected keypad, all other keypads are locked out for 10 seconds after the last key press.

DISARMING THE SYSTEM

To disarm the system normally, use any connected keypad to enter the password while the system is armed.

Note: When the system is in exit delay mode, press CAN- CEL to disarm the system.

If you enter the correct password, ARMED on the keypad turns off, and the alarm system is disarmed. If you enter the wrong password, the system remains armed, but gives no indication a wrong code was entered.

Note: If you enter the wrong password three times in a row, the alarm center locks out all connected keypads for 5 min- utes. This prevents an intruder from easily determining your password by trying random combinations.

If your alarm system was activated while it was armed and the alarm sounded, ARMED on the keypad flashes to show that the alarm had sounded. To stop the alarm, enter the password. To stop ARMED from flashing, press CANCEL.

If your alarm system was activated and the alarm sounds, enter the duress code to disarm the system. The alarm stops, but the security dialer still sends the emergency mes- sage. To stop the security dialer, enter the password.

If the system is armed, opening the front cabinet or taking the alarm center off the wall triggers the alarm. Make sure to disarm the system before you open the cabinet or remove the alarm center from the wall.

SOUNDING A PANIC ALARM

You can activate the alarm system’s panic alarm at any time, even if the system is not armed.

To sound a panic alarm, press any installed panic button (if you installed a panic/tamper zone) or press ENTER and CANCEL at the same time on any remote keypad. The alarm sounds and the system automatically arms.

CHANGING THE PASSWORD

Arm or disarm the alarm center by using the number keys on the remote keypad to enter a four-digit password you choose. The default password for the alarm center is 1234.

Follow these steps to enter a new password.

1.If the alarm center is armed, use the keypad to enter the current password or 1 2 3 4 (the default password). The alarm center is disarmed.

16

 

Operation

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Image 16
Contents Two-Zone Burglar Alarm System ˆ Features REQUIRED/OPTIONAL AccessoriesSupplied Items Important Notesˆ a Quick Look at Your Alarm Center/Keypad Power GND DATA2 Anncˆ Preparation Understanding the SystemUnderstanding Zones Planning Your Security SystemInstant Zone Delayed Zone System Planning Worksheet Room/Area Door Window Sensor Sounder OtherSafeguarding Planning Records Other Ways to Improve SecurityMaking a Shopping List Securing Your Home or OfficeProperty Inventory List Number Model Serial No Value Insured Y/N Where/How MarkedSetting UP the System Choosing a Location for the Alarm CenterUsing the Tamper Switches Mounting the Alarm CenterChoosing a Location for the Remote Keypad Choosing the ComponentsSensors Sirens and Lights Automatic Telephone Dialerˆ Installation System Wiring ConnectionsConnecting Remote Keypads Mounting the KeypadConnecting Sensors Into Loops Setting the Keypad’s AddressConnecting Loops of Sensors to the Alarm Center Jumpers on Normally-Closed TerminalsConnecting a PRE-ALARM Buzzer Connecting and Powering a Remote Security DeviceConnecting a Siren AND/OR Lights Connecting AC PowerFm Page 15 Wednesday, January 17, 2001 1037 AM Sounding a Panic Alarm Changing the Passwordˆ Operation Arming the Systemˆ Testing the System Using Annunciate ModeSetting the Entry and Exit Delay System ResetChecking the Indicators Testing the Siren AND/OR LightsWeekly System Check ˆ Care Resetting the AC ADAPTER’S Circuit BreakerReplacing the Fuse ˆ Specifications Limited Ninety-Day Warranty

Two-Zone Burglar Alarm System specifications

The Radio Shack Two-Zone Burglar Alarm System is designed to provide homeowners and small business owners with effective security solutions. This system offers an excellent balance of functionality, reliability, and affordability, making it a popular choice for those looking to enhance their property's safety.

One of the standout features of the Radio Shack Two-Zone Burglar Alarm System is its dual-zone capability. This allows users to monitor multiple areas of their property separately. For example, one zone can be designated for exterior doors, while another can monitor interior spaces, which can help to prevent false alarms triggered by pets or other movements within the home. This feature is particularly useful for larger properties that require more than just a single-point monitoring system.

The system is equipped with multiple sensors, including door and window contacts, which can easily be installed to ensure comprehensive coverage. These sensors are designed to detect unauthorized entry and trigger the alarm whenever a door or window is opened. The system also includes passive infrared motion sensors that can identify movement within a designated area, adding an additional layer of security against intruders.

In terms of technologies, the Radio Shack Two-Zone Burglar Alarm System utilizes a microprocessor-controlled control panel, which is at the heart of the system's operations. This logic board processes signals from all connected sensors and determines when to trigger the alarm. The system can provide alerts via a loud siren, while also allowing for notifications to be sent to the owner’s smartphone or other devices, depending on the model.

The installation process for the Radio Shack burglar alarm system is user-friendly, designed for ease even for those who may not be technically savvy. The system typically includes clear instructions and mounting hardware, making setup straightforward. Users can customize their alarm system according to their specific needs and property layout, which further enhances usability.

Another important characteristic of the Radio Shack Two-Zone Burglar Alarm System is the option for battery backup. This ensures that the alarm continues to operate even during power outages, allowing for uninterrupted security coverage. Moreover, the system is frequently praised for its durability and resistance to environmental factors, making it a robust choice for various settings.

Overall, the Radio Shack Two-Zone Burglar Alarm System represents a practical and efficient security solution, combining essential features, advanced technology, and user-friendly installation, all designed to meet the security needs of modern users.