New Buck Corporation GAS STOVE HEATER installation manual Installation, MA CVFB200NAT, Gas Supply

Page 15
INSTALLATION

INSTALLATION

INSTALLING GAS LOG HEATER FIREBOX MODELS MA CVFB200LP OR

MA CVFB200NAT

CAUTION: Do not remove the metal data plates attached to the heater as- sembly. The data plates contain impor- tant warranty information.

CAUTION: After installation and periodically thereafter, check to ensure that no flame comes in contact with any log. If so, reposition logs according to the log installation instructions in this manual. Flames contacting logs will create soot.

1. Remove logs and heater from carton.

6. Inside of Firebox you will find three

MANUAL

(3)wires with a switch attached. Dis- connect the wires from the switch.

Using the remaining mounting bracket SWITCH

with the switch holder on top, feed

 

the wires through the wire channel

RED

starting at the end opposite the switch

holder. Continue through the switch

WIRE

hole in top. Reconnect the three (3)

MOUNT-

wires to the switch (make sure the red

wire is connected to the Manual side

ING

of the switch, see page 33). Position

BRACKET

the switch in the switch holder, press

 

until switch locks into position. (See

 

Figure 15). Take mounting bracket

 

and attach to left rear side of stove,

 

with bolts provided. (See Figure 14)

 

7. Place freestanding stove in desired

 

position in room. Be sure to maintain

 

clearances to combustibles as outlined

 

on page 6.

 

8. After positioning stove in desired po-

 

sition, connect gas supply and com-

 

plete all pressure checks and light the

 

heater. (See page 14 Connecting To

 

Gas Supply)

 

OFF AUTO

SWITCH

HOLDER

WIRE

CHANNEL

NOTE: Do not pick up gas heater by

the burner itself. This could damage

heater. Always handle the heater by

the firebox only.

 

2. Remove all protective packaging ap-

plied to logs and gas log heater for

shipment.

 

3. Check all items for any shipping

damage. If damaged, promptly inform

dealer where you bought heater. Place

the logs into the Firebox and follow

the directions on page 10, Figure 13.

4. If not already removed, remove back

panel from assembled stove body

(Stoves sold for the use of a Model

CVF200’s series may not have a back

panel, just the bolts). See back panel

and bolts on page 7, Figure 5. Use a

10mm socket or an adjustable

wrench. Remove six (6) bolts and

washers. Keep bolts and washers to

attach Rear Mounting Brackets.

5. From rear of stove slide the Firebox

into the Cast Stove until the front of

the Firebox touches

the inner front

rear side of the stove. The Firebox

has two Alignment Guides made to

the bottom of the Firebox. These will

ensure a more proper center align-

ment of the Firebox in the Cast Stove.

Then take the mounting bracket with-

out a switch holder and align slots in

bracket with top and

bottom holes on

right side of stove. Fasten with bolts

provided. (See Figure 14)

FIGURE 15 - BRACKET/WIRE

CHANNEL

SWITCH HOLDER (ALSO REFER TO

PAGE 16)

LEFT

SWITCH

OPTIONAL AIR CHANNEL/

RIGHT

BLOWER ASSEMBLY

REAR

 

REAR

 

 

SIDE

SIDE

 

 

 

 

 

MOUNTING BRACKETS

 

BOLTS

 

 

BOLTS

 

 

 

Alignment Guides

FIGURE 14 - BACK OF STOVE WITH FIREBOX INSERT / MOUNT- ING BRACKETS / SWITCH/ OPTIONAL AIR CHANNEL WITH BLOWER.

11

Image 15
Contents Page Page TABLE OF CONTENTS CAST STOVE SERIES IDENTIFICATION NUMBERS AND DESCRIPTIONS FORVENT-FREENATURAL OR L.P GAS STOVE HEATER SAFETY INFORMATION WARNINGSLOCAL CODES PRODUCT FEATURESSAFETY PILOT PRODUCT INDENTIFICATIONConfined and Unconfined Space AIR FOR COMBUSTION AND VENTILATIONPROVIDING ADEQUATE VENTILATION Unusually Tight ConstructionDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION ContinuedVENTILATION AIR Ventilation Air From OutdoorsContinued COMBUSTIBLES Vent-FreeOperation Only INSTALLATIONGAS CONNECTION CLEARANCES TOContinued STOVE CAVITY ASSEMBLYContinued 10.Install door catch bolt M8Continued MA C100BATNATIMPORTANT Make “LOG #2 PLACEMENT” INSTALLATION MA CVFB200NATGas Supply CONTINUED REMOVING CAST STOVE FRONT PANELMODEL MA CVF714 INSTALLATION OF OPTIONAL BLOWER ASSEMBLYContinued CONNECTING TO GAS SUPPLYInstallation Items Needed Accessories, pageContinued Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System For purpose of input adjustmentPage IGNITOR BUTTON FLAME ADJUSTMENT KNOB THERMOCOUPLE PILOT BURNERSWITCH IGNITOR ELECTRODEPILOT FLAME PATTERN MILLIVOLT OPTIONAL REMOTE CONTROLSee Troubleshooting, pages 20 through ContinuedTRANSPORTING STOVE INSPECTING AND CLEANING MAINTENANCELOGS MAIN BURNERMaintenance OBSERVED PROBLEMCleaning and Maintenance, page 19 orREMEDY OBSERVED PROBLEMCleaning and Maintenance, page POSSIBLE CAUSEDo not try to light any appliance OBSERVED PROBLEMand Maintenance, page WARNING If you smell gas Shut off gas supplyWALL THERMOSTAT PART# PE ACCESSORIESSERVICE HINTS REPLACEMENT PARTSNOTE REFER TO PAGES 25 AND PARTS LISTFOR MODELS MA C100BALTLP, MA C100BATNAT, AND MA CVFB200LP, MA CVFB200NATPage Page Discarded During Assembly PARTS BREAKDOWN FOR CAST STOVE SERIES TOWNSENDTOWNSEND PARTS LISTPARTS AVAILABLE-NOTSHOW TOWNSEND PARTS BREAKDOWN FOR CAST STOVE SERIES HEPPLEWHITE PARTS LIST HEPPLEWHITE PARTS LIST HEPPLEWHITE PARTS AVAILABLE-NOTSHOWN HEPPLEWHITEWIRING DIAGRAM