ACCESSORIES

Purchase these heater accessories from your local dealer. If they can not sup- ply these accessories, call our Parts Department at 1-828-765-6144 for re- ferral information. You can also write to the address listed on the back page of this manual.

RECEIVER AND HAND-HELD REMOTE CONTROL KIT PART# PO FDC-504

For remote-ready models. Allows the gas log heater to be turned on and off by using a hand-held remote control.

WALL THERMOSTAT

PART# PE 400142

The desired comfort setting can be se- lected on the wall thermostat and the log heater will automatically cycle from pilot to the heat setting selected.

SERVICE HINTS

When Gas Pressure Is Too Low

Pilot will not stay lit

Burners will have delayed ignition

Heater will not produce specified heat

When Gas Quality Is Bad

Pilot will not stay lit

Burners will produce flames and soot

Heater will backfire when lit

You may feel your gas pressure is too low or gas quality is bad. If so, contact your local gas supplier.

REPLACEMENT

PARTS

NOTE: Use only original replacement parts. This will protect your warranty coverage for parts replaced under warranty.

23

Image 27
Contents Page Page TABLE OF CONTENTS CAST STOVE SERIES IDENTIFICATION NUMBERS AND DESCRIPTIONS FORVENT-FREENATURAL OR L.P GAS STOVE HEATER SAFETY INFORMATION WARNINGSLOCAL CODES PRODUCT FEATURESSAFETY PILOT PRODUCT INDENTIFICATIONConfined and Unconfined Space AIR FOR COMBUSTION AND VENTILATIONPROVIDING ADEQUATE VENTILATION Unusually Tight ConstructionDETERMINING FRESH-AIRFLOW FOR HEATER LOCATION ContinuedVENTILATION AIR Ventilation Air From OutdoorsContinued COMBUSTIBLES Vent-FreeOperation Only INSTALLATIONGAS CONNECTION CLEARANCES TOContinued STOVE CAVITY ASSEMBLYContinued 10.Install door catch bolt M8Continued MA C100BATNATIMPORTANT Make “LOG #2 PLACEMENT” INSTALLATION MA CVFB200NATGas Supply CONTINUED REMOVING CAST STOVE FRONT PANELMODEL MA CVF714 INSTALLATION OF OPTIONAL BLOWER ASSEMBLYContinued CONNECTING TO GAS SUPPLYInstallation Items Needed Accessories, pageContinued Pressure Testing Heater Gas ConnectionsPressure Testing Gas Supply Piping System For purpose of input adjustmentPage IGNITOR BUTTON FLAME ADJUSTMENT KNOB THERMOCOUPLE PILOT BURNERSWITCH IGNITOR ELECTRODEPILOT FLAME PATTERN MILLIVOLT OPTIONAL REMOTE CONTROLSee Troubleshooting, pages 20 through ContinuedTRANSPORTING STOVE INSPECTING AND CLEANING MAINTENANCELOGS MAIN BURNERMaintenance OBSERVED PROBLEMCleaning and Maintenance, page 19 orREMEDY OBSERVED PROBLEMCleaning and Maintenance, page POSSIBLE CAUSEDo not try to light any appliance OBSERVED PROBLEMand Maintenance, page WARNING If you smell gas Shut off gas supplyWALL THERMOSTAT PART# PE ACCESSORIESSERVICE HINTS REPLACEMENT PARTSNOTE REFER TO PAGES 25 AND PARTS LISTFOR MODELS MA C100BALTLP, MA C100BATNAT, AND MA CVFB200LP, MA CVFB200NATPage Page Discarded During Assembly PARTS BREAKDOWN FOR CAST STOVE SERIES TOWNSENDTOWNSEND PARTS LISTPARTS AVAILABLE-NOTSHOW TOWNSEND PARTS BREAKDOWN FOR CAST STOVE SERIES HEPPLEWHITE PARTS LIST HEPPLEWHITE PARTS LIST HEPPLEWHITE PARTS AVAILABLE-NOTSHOWN HEPPLEWHITEWIRING DIAGRAM