Bryant GT-PG (50YE) manual Performance Data GT-PG Model 018 PSC Blower, Psi Eer Lat

Page 13

Bryant Geothermal Heat Pump Systems

Performance Data — GT-PG Model 018 - PSC Blower

600 CFM Nominal (Rated) Airflow Cooling, 600 CFM Nominal (Rated) Airflow HeatingPerformance capacities shown in thousands of Btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EWT

 

WPD

 

 

Cooling - EAT 80/67°F

 

 

 

 

Heating - EAT 70°F

 

 

GPM

 

 

Airflow

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

°F

 

PSI

FT

TC

SC

kW

HR

 

EER

HW

HC

kW

 

HE

LAT

 

COP

HW

 

 

CFM

 

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

5.5

3.9

9.0

 

 

Operation not recommended

 

 

450

12.2

1.36

 

7.8

95.0

 

2.6

1.4

5.5

3.9

9.0

 

 

 

 

600

12.5

1.24

 

8.3

89.3

 

2.9

1.4

 

 

 

 

 

 

 

 

 

 

 

 

2.8

0.7

1.6

450

20.7

16.8

0.78

23.3

 

26.6

0.5

450

13.7

1.40

 

9.2

98.1

 

2.9

1.7

 

2.8

0.7

1.6

600

21.5

14.0

0.80

24.3

 

26.8

0.6

600

14.0

1.28

 

9.7

91.7

 

3.2

1.7

30

4.1

2.1

4.9

450

21.0

16.8

0.74

23.5

 

28.4

0.5

450

14.2

1.41

 

9.6

99.3

 

2.9

1.7

4.1

2.1

4.9

600

21.8

14.1

0.76

24.4

 

28.6

0.5

600

14.6

1.29

 

10.2

92.5

 

3.3

1.8

 

 

 

 

 

5.5

3.5

8.1

450

21.2

16.8

0.72

23.6

 

29.3

0.5

450

14.5

1.42

 

9.9

99.9

 

3.0

1.8

 

5.5

3.5

8.1

600

22.0

14.1

0.75

24.6

 

29.6

0.5

600

14.9

1.30

 

10.5

93.0

 

3.4

1.8

 

2.8

0.6

1.4

450

20.8

17.2

0.85

23.7

 

24.5

0.9

450

15.8

1.44

 

11.1

102.6

 

3.2

1.9

 

2.8

0.6

1.4

600

21.7

14.4

0.88

24.6

 

24.7

0.9

600

16.3

1.32

 

11.8

95.1

 

3.6

2.0

40

4.1

2

4.6

450

21.0

17.2

0.81

23.7

 

26.0

0.8

450

16.5

1.45

 

11.7

103.9

 

3.3

2.0

4.1

2

4.6

600

21.8

14.4

0.83

24.7

 

26.2

0.9

600

16.9

1.33

 

12.4

96.1

 

3.7

2.0

 

 

 

 

 

5.5

3.2

7.4

450

21.2

17.3

0.79

23.9

 

26.9

0.8

450

16.8

1.46

 

12.0

104.7

 

3.4

2.1

 

5.5

3.2

7.4

600

22.1

14.5

0.81

24.8

 

27.1

0.8

600

17.3

1.33

 

12.8

96.7

 

3.8

2.1

 

2.8

0.5

1.2

450

20.6

17.3

0.95

23.9

 

21.8

1.4

450

18.0

1.47

 

13.1

107.0

 

3.6

2.2

 

2.8

0.5

1.2

600

21.5

14.5

0.98

24.8

 

22.0

1.5

600

18.5

1.35

 

13.9

98.5

 

4.0

2.2

50

4.1

1.7

3.9

450

21.0

17.5

0.89

24.0

 

23.5

1.3

450

18.7

1.48

 

13.8

108.6

 

3.7

2.3

4.1

1.7

3.9

600

21.8

14.6

0.92

25.0

 

23.7

1.3

600

19.2

1.35

 

14.6

99.7

 

4.2

2.3

 

 

 

 

 

5.5

2.8

6.5

450

21.1

17.5

0.86

24.0

 

24.4

1.2

450

19.2

1.49

 

14.2

109.4

 

3.8

2.3

 

5.5

2.8

6.5

600

21.9

14.6

0.89

25.0

 

24.6

1.2

600

19.7

1.36

 

15.1

100.4

 

4.2

2.4

 

2.8

0.3

0.7

450

19.9

16.8

1.05

23.5

 

18.9

1.9

450

20.1

1.50

 

15.1

111.4

 

3.9

2.4

 

2.8

0.3

0.7

600

20.7

14.1

1.09

24.4

 

19.1

2.0

600

20.7

1.37

 

16.0

101.9

 

4.4

2.5

60

4.1

1.5

3.5

450

20.4

17.2

0.99

23.7

 

20.6

1.7

450

21.0

1.51

 

15.9

113.3

 

4.1

2.5

4.1

1.5

3.5

600

21.2

14.3

1.02

24.7

 

20.8

1.8

600

21.6

1.38

 

16.9

103.3

 

4.6

2.6

 

 

 

 

 

5.5

2.6

6.0

450

20.6

17.3

0.96

23.8

 

21.5

1.6

450

21.5

1.52

 

16.4

114.3

 

4.1

2.6

 

5.5

2.6

6.0

600

21.4

14.4

0.99

24.8

 

21.7

1.6

600

22.1

1.39

 

17.4

104.1

 

4.7

2.7

 

2.8

0.3

0.7

450

18.9

16.2

1.17

22.9

 

16.1

2.6

450

22.3

1.54

 

17.1

115.9

 

4.3

2.7

 

2.8

0.3

0.7

600

19.7

13.5

1.21

23.8

 

16.2

2.7

600

22.9

1.40

 

18.1

105.4

 

4.8

2.8

70

4.1

1.4

3.2

450

19.5

16.6

1.10

23.2

 

17.7

2.3

450

23.4

1.56

 

18.0

118.1

 

4.4

2.8

4.1

1.4

3.2

600

20.3

13.8

1.14

24.2

 

17.9

2.4

600

24.0

1.43

 

19.1

107.0

 

4.9

2.9

 

 

 

 

 

5.5

2.4

5.5

450

19.8

16.8

1.07

23.4

 

18.6

2.1

450

23.9

1.57

 

18.5

119.3

 

4.5

2.9

 

5.5

2.4

5.5

600

20.6

14.0

1.10

24.3

 

18.7

2.1

600

24.6

1.44

 

19.7

107.9

 

5.0

3.0

 

2.8

0.2

0.5

450

17.7

15.4

1.31

22.2

 

13.6

3.1

450

24.6

1.59

 

19.1

120.6

 

4.5

3.0

 

2.8

0.2

0.5

600

18.5

12.9

1.35

23.1

 

13.7

3.2

600

25.2

1.46

 

20.3

108.9

 

5.1

3.0

80

4.1

1.2

2.8

450

18.4

15.9

1.23

22.6

 

15.0

2.9

450

25.8

1.63

 

20.2

123.1

 

4.6

3.1

4.1

1.2

2.8

600

19.2

13.2

1.27

23.5

 

15.1

3.0

600

26.5

1.49

 

21.4

110.9

 

5.2

3.2

 

 

 

 

 

5.5

2.2

5.1

450

18.7

16.1

1.19

22.8

 

15.7

2.6

450

26.5

1.66

 

20.7

124.5

 

4.7

3.2

 

5.5

2.2

5.1

600

19.5

13.4

1.23

23.7

 

15.9

2.7

600

27.2

1.52

 

22.0

111.9

 

5.3

3.3

 

2.8

0.2

0.5

450

17.1

15.0

1.39

21.9

 

12.4

3.4

450

25.8

1.63

 

20.1

123.0

 

4.6

3.1

 

2.8

0.2

0.5

600

17.8

12.6

1.43

22.7

 

12.5

3.6

600

26.4

1.49

 

21.3

110.8

 

5.2

3.2

85

4.1

1.15

2.7

450

17.8

15.5

1.30

22.2

 

13.7

3.2

450

27.1

1.69

 

21.2

125.7

 

4.7

3.2

4.1

1.15

2.7

600

18.5

12.9

1.35

23.1

 

13.8

3.3

600

27.8

1.54

 

22.5

112.9

 

5.3

3.3

 

 

 

 

 

5.5

2.1

4.9

450

18.1

15.7

1.26

22.4

 

14.4

2.9

450

27.8

1.72

 

21.8

127.2

 

4.7

3.3

 

5.5

2.1

4.9

600

18.9

13.1

1.30

23.3

 

14.6

3.1

600

28.6

1.58

 

23.2

114.1

 

5.3

3.4

 

2.8

0.2

0.5

450

16.5

14.7

1.46

21.5

 

11.3

3.9

450

26.9

1.68

 

21.1

125.4

 

4.7

3.2

 

2.8

0.2

0.5

600

17.2

12.3

1.51

22.4

 

11.4

4.1

600

27.7

1.53

 

22.4

112.7

 

5.3

3.3

90

4.1

1.1

2.5

450

17.2

15.1

1.38

21.9

 

12.5

3.6

450

28.4

1.74

 

22.3

128.3

 

4.8

3.3

4.1

1.1

2.5

600

17.9

12.6

1.42

22.8

 

12.6

3.8

600

29.1

1.60

 

23.6

114.9

 

5.3

3.4

 

 

 

 

 

5.5

2

4.6

450

17.5

15.3

1.33

22.1

 

13.1

3.3

450

29.1

1.79

 

22.9

130.0

 

4.8

3.5

 

5.5

2

4.6

600

18.3

12.8

1.38

23.0

 

13.2

3.5

600

29.9

1.63

 

24.3

116.2

 

5.4

3.6

 

2.8

0.2

0.5

450

15.2

14.0

1.64

20.8

 

9.3

4.3

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

2.8

0.2

0.5

600

15.9

11.7

1.69

21.7

 

9.4

4.5

600

0.0

0.0

 

0.0

0.0

 

0.0

0.0

100

4.1

1.1

2.5

450

15.9

14.3

1.54

21.2

 

10.3

4.1

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

4.1

1.1

2.5

600

16.6

12.0

1.59

22.0

 

10.4

4.3

600

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

 

 

 

 

5.5

1.9

4.4

450

16.3

14.5

1.50

21.4

 

10.9

4.0

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

5.5

1.9

4.4

600

16.9

12.1

1.55

22.2

 

10.9

4.2

600

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

2.8

0.1

0.2

450

14.0

13.4

1.84

20.3

 

7.6

5.1

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

2.8

0.1

0.2

600

14.6

11.2

1.90

21.1

 

7.7

5.3

600

0.0

0.0

 

0.0

0.0

 

0.0

0.0

110

4.1

0.9

2.1

450

14.6

13.7

1.73

20.5

 

8.4

5.0

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

4.1

0.9

2.1

600

15.2

11.4

1.79

21.4

 

8.5

5.2

600

0.0

Operation0.0

 

not0.0

recommended0.0 0.0

0.0

 

5.5

1.7

3.9

450

15.0

13.8

1.68

20.7

 

8.9

4.8

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

5.5

1.7

3.9

600

15.6

11.6

1.74

21.5

 

9.0

5.0

600

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

2.8

0.1

0.2

450

12.9

13.1

2.06

19.9

 

6.2

6.1

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

2.8

0.1

0.2

600

13.4

10.9

2.13

20.7

 

6.3

6.3

600

0.0

0.0

 

0.0

0.0

 

0.0

0.0

120

4.1

0.8

1.8

450

13.4

13.2

1.94

20.1

 

6.9

5.9

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

4.1

0.8

1.8

600

14.0

11.0

2.01

20.8

 

7.0

6.1

600

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

 

 

 

 

5.5

1.6

3.7

450

13.7

13.3

1.89

20.2

 

7.3

5.6

450

0.0

0.0

 

0.0

0.0

 

0.0

0.0

 

5.5

1.6

3.7

600

14.3

11.1

1.95

21.0

 

7.3

5.9

600

0.0

0.0

 

0.0

0.0

 

0.0

0.0

Interpolation is permissible; extrapolation is not.

All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating.

AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.

Table does not reflect fan or pump power corrections for AHRI/ISO conditions.

All performance is based upon the lower voltage of dual voltage rated units.

Operation below 40°F EWT is based upon a 15% methanol antifreeze solution.

Operation below 60°F EWT requires optional insulated water/refrigerant circuit.

See performance correction tables for operating conditions other than those listed above.

For operation in the shaded areas, please see the Performance Data Selection Notes.

Residential Products Technical Guide

GT-PG

13

 

 

 

Image 13
Contents GT-PG 50YE Packaged Series GT-PG 50YE Series Table of ContentsWhats New with Bryant Geothermals GT-PG? Other New FeaturesPuron Refrigerant Tin-Coated Air CoilGT-PG Design Features Options & Accessories Series Revision Level Unit Model KeyAbout AHRI/ISO/ASHRAE About AHRI/ISO/ASHRAETest Condition Comparison Table Ground Water Heat Pump Ground Loop Heat Pump AHRI/ISO/ASHRAE/ANSI 13256-1 PerformanceBtuh/W BtuhCooling Reference Calculations & LegendSensible Power PowerAir Flow Correction Factors 75%Air DBF Entering Air Correction FactorsAir WBF Performance Data Selection Notes This is due to the potential of the refrigerant temperaturePSI EER LAT Performance Data GT-PG Model 018 PSC BlowerPerformance Data GT-PG Model 018 ECM Blower PSI Performance Data GT-PG Model 024 PSC BlowerOperation Not recommended Performance Data GT-PG Model 024 ECM BlowerPerformance Data GT-PG Model 030 PSC Blower AOperation Performance Data GT-PG Model 030 ECM BlowerPerformance Data GT-PG Model 036 PSC Blower Performance Data GT-PG Model 036 ECM Blower 110 Performance Data GT-PG Model 042 PSC BlowerPerformance Data GT-PG Model 042 ECM Blower Performance Data GT-PG Model 048 PSC Blower Operation Performance Data GT-PG Model 048 ECM BlowerPerformance Data GT-PG Model 060 PSC Blower Performance Data GT-PG Model 060 ECM Blower Performance Data GT-PG Model 070 ECM Blower Physical Data Dimensions Vertical Upflow GT-PG 50YE Series Return Discharge Connection Return ConnectionDimensions Vertical Downflow GT-PG 50YE Series Floor Foot Print Dimensions Horizontal GT-PG 50YE Series +/- 0.20 in, +/- 5.1mm Model 1Discharge Connection Return ConnectionElectrical Data GT-PG ECM Electrical Wiring Diagram 96B0005N37 GT-PG PSC Electrical Wiring Diagram 96B0005N36 Bryant Whatever it Takes GT-PG ECM Control Features ECM Board Tap Settings Aux ECM Blower Performance DataIn. wg 640 800 400 500 620Airflow cfm at External Static Pressure in. wg PSC Blower Performance DataAuxiliary Heat Electrical Data Auxiliary Electric Heat Auxiliary Heat RatingsAuxiliary KW Rating Btuh Rating MinimumEngineering Guide Specifications Accessories & Warranty Warranty Information Accessories & OptionsGT-PG 50YE Series Bryant Geothermal Heat Pump Systems Revision History ECM Electrical Data Updated

GT-PG (50YE) specifications

The Bryant GT-PG (50YE) is a state-of-the-art gas-fired packaged unit ideal for both commercial and residential applications. Renowned for its efficiency and reliability, this model stands out in the competitive HVAC market. With its sleek design and advanced features, it promises optimal performance while maintaining energy efficiency, making it a favorite among building owners and contractors alike.

One of the most remarkable features of the Bryant GT-PG (50YE) is its high-efficiency gas heat exchanger. This component enhances energy transfer, ensuring that maximum heat is produced with minimal energy consumption. With an Annual Fuel Utilization Efficiency (AFUE) rating that meets and exceeds industry standards, users can count on significant savings in energy bills over time. Additionally, the unit is equipped with a multi-speed blower that further enhances its efficiency by providing a consistent flow of air while reducing noise levels.

Another significant characteristic of the GT-PG (50YE) is its advanced control system. Featuring a user-friendly interface, this system allows for precise temperature control and integration with smart home technologies. The modulating gas valve optimizes performance based on heating demand, providing customized comfort for any environment.

Reliability is key with the Bryant GT-PG (50YE). It is built with sturdy materials designed to withstand the elements, enhancing its lifespan and reducing maintenance needs. The inclusion of a robust stainless steel heat exchanger aids in preventing corrosion, ensuring durability in various climates.

Moreover, safety features are paramount in the design of the GT-PG (50YE). It includes integrated safety controls, such as a flame rollout switch and limit control, providing peace of mind for users.

Installation and maintenance are made easy with this model, which includes a compact design allowing for versatile placement options. Service access has been thoughtfully designed, ensuring technicians can perform routine maintenance without hassle.

In conclusion, the Bryant GT-PG (50YE) is a powerhouse of an HVAC solution, blending efficiency, reliability, and advanced technology. With its exceptional heating capabilities, user-friendly controls, and durable construction, this model is perfect for anyone looking to invest in long-term comfort and performance. Whether for residential or commercial use, the GT-PG reflects Bryant's commitment to quality and customer satisfaction.