Bryant GT-PG (50YE) manual Performance Data GT-PG Model 030 PSC Blower

Page 17

Bryant Geothermal Heat Pump Systems

Performance Data — GT-PG Model 030 - PSC Blower

950 CFM Nominal (Rated) Airflow Cooling,950 CFM Nominal (Rated) Airflow HeatingPerformance capacities shown in thousands of Btuh

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

EWT

 

WPD

 

 

Cooling - EAT 80/67°F

 

 

 

 

Heating - EAT 70°F

 

 

GPM

 

 

Airflow

 

 

 

 

 

 

 

Airflow

 

 

 

 

 

 

 

 

°F

 

PSI

FT

TC

SC

kW

HR

 

EER

HW

HC

kW

 

HE

LAT

 

COP

HW

 

 

CFM

 

CFM

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

20

8.0

5.6

12.9

N/A

N/A

N/A

N/A

N/A

 

N/A

N/A

715

19.9

2.10

 

13.1

96

 

2.78

2.0

8.0

5.6

12.9

N/A

N/A

OperationN/A

notN/ArecommendedN/A

 

N/A

N/A

950

20.4

1.92

 

13.9

90

 

3.12

2.1

 

4.0

1.5

3.5

715

28.8

16.3

1.18

32.8

 

24.4

0.6

715

21.7

2.13

 

14.8

98

 

2.99

2.5

 

4.0

1.5

3.5

950

30.0

19.5

1.22

34.1

 

24.6

0.6

950

22.3

1.95

 

15.7

92

 

3.36

2.5

30

6.0

3.1

7.2

715

28.9

16.3

1.14

32.8

 

25.3

0.5

715

22.5

2.14

 

15.6

99

 

3.08

2.6

6.0

3.1

7.2

950

30.1

19.6

1.18

34.1

 

25.5

0.6

950

23.1

1.96

 

16.5

93

 

3.46

2.6

 

 

 

 

 

8.0

5.1

11.8

715

29.0

16.4

1.11

32.8

 

26.0

0.5

715

23.0

2.15

 

16.0

100

 

3.13

2.7

 

8.0

5.1

11.8

950

30.2

19.6

1.15

34.1

 

26.2

0.5

950

23.6

1.97

 

16.9

93

 

3.52

2.7

 

4.0

1.3

3.0

715

31.0

17.8

1.30

35.5

 

23.9

1.0

715

24.7

2.18

 

17.5

102

 

3.32

2.9

 

4.0

1.3

3.0

950

32.3

21.3

1.34

36.9

 

24.1

1.0

950

25.3

1.99

 

18.6

95

 

3.72

2.9

40

6.0

2.8

6.5

715

31.2

17.8

1.25

35.5

 

24.9

0.9

715

25.6

2.20

 

18.4

103

 

3.42

3.0

6.0

2.8

6.5

950

32.5

21.3

1.30

36.9

 

25.1

1.0

950

26.3

2.01

 

19.5

96

 

3.84

3.0

 

 

 

 

 

8.0

4.5

10.4

715

31.4

17.8

1.22

35.5

 

25.7

0.8

715

26.2

2.21

 

18.9

104

 

3.47

3.1

 

8.0

4.5

10.4

950

32.7

21.4

1.26

36.9

 

25.9

0.9

950

26.9

2.02

 

20.0

96

 

3.90

3.2

 

4.0

1.3

3.0

715

31.9

18.5

1.44

36.8

 

22.2

1.6

715

27.7

2.24

 

20.2

106

 

3.62

3.3

 

4.0

1.3

3.0

950

33.2

22.2

1.49

38.3

 

22.4

1.6

950

28.4

2.05

 

21.4

98

 

4.07

3.3

50

6.0

2.6

6.0

715

32.2

18.5

1.37

36.8

 

23.4

1.4

715

28.8

2.26

 

21.2

107

 

3.74

3.4

6.0

2.6

6.0

950

33.5

22.2

1.42

38.3

 

23.6

1.5

950

29.6

2.07

 

22.5

99

 

4.19

3.5

 

 

 

 

 

8.0

4.3

9.9

715

32.3

18.5

1.34

36.9

 

24.2

1.3

715

29.4

2.27

 

21.8

108

 

3.79

3.5

 

8.0

4.3

9.9

950

33.7

22.2

1.38

38.3

 

24.4

1.3

950

30.2

2.08

 

23.1

99

 

4.26

3.6

 

4.0

1.2

2.8

715

31.0

18.2

1.60

36.4

 

19.4

2.2

715

30.6

2.30

 

22.9

110

 

3.91

3.7

 

4.0

1.2

2.8

950

32.3

21.8

1.65

37.9

 

19.6

2.3

950

31.5

2.10

 

24.3

101

 

4.39

3.8

60

6.0

2.5

5.8

715

31.7

18.5

1.51

36.8

 

21.1

2.0

715

31.9

2.32

 

24.1

111

 

4.03

3.8

6.0

2.5

5.8

950

33.0

22.1

1.56

38.3

 

21.2

2.0

950

32.8

2.12

 

25.6

102

 

4.53

3.9

 

 

 

 

 

8.0

4.0

9.2

715

32.0

18.5

1.46

36.9

 

21.9

1.7

715

32.6

2.34

 

24.7

112

 

4.09

4.0

 

8.0

4.0

9.2

950

33.3

22.2

1.51

38.4

 

22.0

1.8

950

33.5

2.14

 

26.2

103

 

4.60

4.1

 

4.0

1.1

2.5

715

29.5

17.6

1.76

35.5

 

16.8

2.9

715

33.6

2.36

 

25.6

114

 

4.18

3.8

 

4.0

1.1

2.5

950

30.7

21.1

1.81

36.9

 

16.9

3.0

950

34.5

2.16

 

27.2

104

 

4.69

4.0

70

6.0

2.3

5.3

715

30.5

18.0

1.65

36.1

 

18.4

2.6

715

35.1

2.39

 

26.9

115

 

4.30

4.0

6.0

2.3

5.3

950

31.7

21.6

1.71

37.5

 

18.5

2.7

950

36.0

2.18

 

28.5

105

 

4.83

4.1

 

 

 

 

 

8.0

3.8

8.8

715

30.9

18.2

1.61

36.4

 

19.2

2.3

715

35.8

2.40

 

27.6

116

 

4.36

4.2

 

8.0

3.8

8.8

950

32.2

21.8

1.66

37.8

 

19.4

2.4

950

36.8

2.20

 

29.3

106

 

4.90

4.3

 

4.0

1.0

2.3

715

27.7

16.8

1.94

34.3

 

14.3

3.5

715

36.6

2.42

 

28.3

117

 

4.43

4.2

 

4.0

1.0

2.3

950

28.8

20.2

2.00

35.6

 

14.4

3.6

950

37.5

2.21

 

30.0

107

 

4.97

4.3

80

6.0

2.2

5.1

715

28.8

17.3

1.83

35.0

 

15.8

3.2

715

38.1

2.46

 

29.6

119

 

4.55

4.4

6.0

2.2

5.1

950

30.0

20.7

1.89

36.4

 

15.9

3.4

950

39.1

2.25

 

31.4

108

 

5.11

4.5

 

 

 

 

 

8.0

3.5

8.1

715

29.3

17.5

1.77

35.4

 

16.6

3.0

715

38.9

2.47

 

30.4

120

 

4.61

4.5

 

8.0

3.5

8.1

950

30.5

21.0

1.83

36.8

 

16.7

3.1

950

40.0

2.26

 

32.2

109

 

5.18

4.7

 

4.0

1.0

2.3

715

26.7

16.4

2.04

33.7

 

13.1

3.9

715

38.0

2.45

 

29.5

119

 

4.54

4.4

 

4.0

1.0

2.3

950

27.8

19.7

2.11

35.0

 

13.2

4.1

950

39.0

2.24

 

31.4

108

 

5.10

4.5

85

6.0

2.2

5.0

715

27.8

16.9

1.92

34.4

 

14.5

3.6

715

39.6

2.49

 

31.0

121

 

4.66

4.6

6.0

2.2

5.0

950

29.0

20.2

1.99

35.8

 

14.6

3.8

950

40.6

2.28

 

32.8

110

 

5.23

4.7

 

 

 

 

 

8.0

3.5

8.0

715

28.4

17.1

1.87

34.7

 

15.2

3.3

715

40.4

2.51

 

31.7

122

 

4.72

4.7

 

8.0

3.5

8.0

950

29.6

20.5

1.93

36.1

 

15.3

3.5

950

41.5

2.30

 

33.6

110

 

5.30

4.9

 

4.0

1.0

2.3

715

25.7

16.0

2.15

33.1

 

12.0

4.5

715

39.4

2.49

 

30.8

121

 

4.65

4.6

 

4.0

1.0

2.3

950

26.8

19.2

2.22

34.4

 

12.1

4.6

950

40.5

2.27

 

32.7

109

 

5.22

4.7

90

6.0

2.1

4.9

715

26.9

16.5

2.02

33.8

 

13.3

4.1

715

41.1

2.53

 

32.3

123

 

4.77

4.7

6.0

2.1

4.9

950

28.0

19.7

2.09

35.1

 

13.4

4.3

950

42.2

2.31

 

34.3

111

 

5.35

4.9

 

 

 

 

 

8.0

3.4

7.9

715

27.4

16.7

1.96

34.1

 

14.0

3.8

715

41.9

2.55

 

33.0

124

 

4.82

4.9

 

8.0

3.4

7.9

950

28.6

20.0

2.03

35.5

 

14.1

4.0

950

43.0

2.33

 

35.1

112

 

5.42

5.1

 

4.0

1.0

2.3

715

23.9

15.3

2.39

32.1

 

10.0

4.9

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

 

4.0

1.0

2.3

950

24.9

18.3

2.47

33.4

 

10.1

5.1

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

100

6.0

1.9

4.4

715

23.2

15.0

2.51

31.7

 

9.2

4.7

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

6.0

1.9

4.4

950

24.1

17.9

2.60

33.0

 

9.3

4.9

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

 

 

 

 

 

 

8.0

3.1

7.2

715

23.6

15.2

2.44

31.9

 

9.7

4.5

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

 

8.0

3.1

7.2

950

24.6

18.1

2.52

33.2

 

9.8

4.7

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

 

4.0

0.9

2.1

715

22.4

14.7

2.68

31.5

 

8.4

5.9

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

 

4.0

0.9

2.1

950

23.3

17.6

2.77

32.8

 

8.4

6.1

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

110

6.0

1.9

4.4

715

23.2

15.0

2.51

31.7

 

9.2

5.7

N/A

N/A

N/A

 

N/A

N/A

 

N/A

 

6.0

1.9

4.4

950

24.1

17.9

2.60

33.0

 

9.3

5.9

N/A

N/A

OperationN/A

 

notN/A

recommendedN/A N/A

 

 

8.0

3.1

7.2

715

23.6

15.2

2.44

31.9

 

9.7

5.5

N/A

N/A

N/A

 

N/A

N/A

N/A

 

 

8.0

3.1

7.2

950

24.6

18.1

2.52

33.2

 

9.8

5.7

N/A

N/A

N/A

 

N/A

N/A

N/A

 

 

4.0

0.9

2.1

715

21.3

14.6

3.02

31.6

 

7.1

6.9

N/A

N/A

N/A

 

N/A

N/A

N/A

 

 

4.0

0.9

2.1

950

22.2

17.4

3.12

32.9

 

7.1

7.2

N/A

N/A

N/A

 

N/A

N/A

N/A

 

120

6.0

1.8

4.2

715

21.8

14.6

2.82

31.5

 

7.7

6.7

N/A

N/A

N/A

 

N/A

N/A

N/A

 

6.0

1.8

4.2

950

22.7

17.5

2.92

32.7

 

7.8

7.0

N/A

N/A

N/A

 

N/A

N/A

N/A

 

 

 

 

 

 

8.0

3.0

6.9

715

22.1

14.7

2.74

31.5

 

8.1

6.4

N/A

N/A

N/A

 

N/A

N/A

N/A

 

 

8.0

3.0

6.9

950

23.0

17.6

2.83

32.7

 

8.1

6.7

N/A

N/A

N/A

 

N/A

N/A

N/A

 

Interpolation is permissible; extrapolation is not.

All entering air conditions are 80°F DB and 67°F WB in cooling, and 70°F DB in heating.

AHRI/ISO certified conditions are 80.6°F DB and 66.2°F WB in cooling and 68°F DB in heating.

Table does not reflect fan or pump power corrections for AHRI/ISO conditions.

All performance is based upon the lower voltage of dual voltage rated units.

Operation below 40°F EWT is based upon a 15% methanol antifreeze solution.

Operation below 60°F EWT requires optional insulated water/refrigerant circuit.

See performance correction tables for operating conditions other than those listed above.

For operation in the shaded areas, please see the Performance Data Selection Notes.

Residential Products Technical Guide

GT-PG

17

 

 

 

Image 17
Contents GT-PG 50YE Packaged Series GT-PG 50YE Series Table of ContentsWhats New with Bryant Geothermals GT-PG? Other New FeaturesPuron Refrigerant Tin-Coated Air CoilGT-PG Design Features Options & Accessories Series Revision Level Unit Model KeyTest Condition Comparison Table About AHRI/ISO/ASHRAEAbout AHRI/ISO/ASHRAE Ground Water Heat Pump Ground Loop Heat Pump AHRI/ISO/ASHRAE/ANSI 13256-1 PerformanceBtuh/W BtuhCooling Reference Calculations & LegendSensible Power PowerAir Flow Correction Factors 75%Air WBF Entering Air Correction FactorsAir DBF Performance Data Selection Notes This is due to the potential of the refrigerant temperaturePSI EER LAT Performance Data GT-PG Model 018 PSC BlowerPerformance Data GT-PG Model 018 ECM Blower PSI Performance Data GT-PG Model 024 PSC BlowerOperation Not recommended Performance Data GT-PG Model 024 ECM BlowerPerformance Data GT-PG Model 030 PSC Blower AOperation Performance Data GT-PG Model 030 ECM BlowerPerformance Data GT-PG Model 036 PSC Blower Performance Data GT-PG Model 036 ECM Blower 110 Performance Data GT-PG Model 042 PSC BlowerPerformance Data GT-PG Model 042 ECM Blower Performance Data GT-PG Model 048 PSC Blower Operation Performance Data GT-PG Model 048 ECM BlowerPerformance Data GT-PG Model 060 PSC Blower Performance Data GT-PG Model 060 ECM Blower Performance Data GT-PG Model 070 ECM Blower Physical Data Dimensions Vertical Upflow GT-PG 50YE Series Return Discharge Connection Return ConnectionDimensions Vertical Downflow GT-PG 50YE Series Floor Foot Print Dimensions Horizontal GT-PG 50YE Series +/- 0.20 in, +/- 5.1mm Model 1Discharge Connection Return ConnectionElectrical Data GT-PG ECM Electrical Wiring Diagram 96B0005N37 GT-PG PSC Electrical Wiring Diagram 96B0005N36 Bryant Whatever it Takes GT-PG ECM Control Features ECM Board Tap Settings Aux ECM Blower Performance DataIn. wg 640 800 400 500 620Airflow cfm at External Static Pressure in. wg PSC Blower Performance DataAuxiliary Heat Electrical Data Auxiliary Electric Heat Auxiliary Heat RatingsAuxiliary KW Rating Btuh Rating MinimumEngineering Guide Specifications Accessories & Warranty Warranty Information Accessories & OptionsGT-PG 50YE Series Bryant Geothermal Heat Pump Systems Revision History ECM Electrical Data Updated

GT-PG (50YE) specifications

The Bryant GT-PG (50YE) is a state-of-the-art gas-fired packaged unit ideal for both commercial and residential applications. Renowned for its efficiency and reliability, this model stands out in the competitive HVAC market. With its sleek design and advanced features, it promises optimal performance while maintaining energy efficiency, making it a favorite among building owners and contractors alike.

One of the most remarkable features of the Bryant GT-PG (50YE) is its high-efficiency gas heat exchanger. This component enhances energy transfer, ensuring that maximum heat is produced with minimal energy consumption. With an Annual Fuel Utilization Efficiency (AFUE) rating that meets and exceeds industry standards, users can count on significant savings in energy bills over time. Additionally, the unit is equipped with a multi-speed blower that further enhances its efficiency by providing a consistent flow of air while reducing noise levels.

Another significant characteristic of the GT-PG (50YE) is its advanced control system. Featuring a user-friendly interface, this system allows for precise temperature control and integration with smart home technologies. The modulating gas valve optimizes performance based on heating demand, providing customized comfort for any environment.

Reliability is key with the Bryant GT-PG (50YE). It is built with sturdy materials designed to withstand the elements, enhancing its lifespan and reducing maintenance needs. The inclusion of a robust stainless steel heat exchanger aids in preventing corrosion, ensuring durability in various climates.

Moreover, safety features are paramount in the design of the GT-PG (50YE). It includes integrated safety controls, such as a flame rollout switch and limit control, providing peace of mind for users.

Installation and maintenance are made easy with this model, which includes a compact design allowing for versatile placement options. Service access has been thoughtfully designed, ensuring technicians can perform routine maintenance without hassle.

In conclusion, the Bryant GT-PG (50YE) is a powerhouse of an HVAC solution, blending efficiency, reliability, and advanced technology. With its exceptional heating capabilities, user-friendly controls, and durable construction, this model is perfect for anyone looking to invest in long-term comfort and performance. Whether for residential or commercial use, the GT-PG reflects Bryant's commitment to quality and customer satisfaction.