Lincoln Electric K126-12, K126-11, K126-10 manual TROUbLESHOOTING

Models: K126-12 K126-11 K126-10

1 27
Download 27 pages 30.04 Kb
Page 21
Image 21

E-3

TROUbLESHOOTING

E-3

 

 

 

 

Observe all Safety Guidelines detailed throughout this manual

 

 

 

 

PRObLEMS

(SYMPTOMS)

POSSIbLE

CAUSE

RECOMMENDED

COURSE OF ACTION

Intermittent wire feed when trigger

1. Drive roll has become galled.

1.

Remove and then clean or

is pulled.

 

 

 

replace drive roll.

 

2.

Wire has become kinked along its

2.

Manually pull wire slowly thru gun

 

 

feed path.

 

until unkinked wire emerges.

 

 

 

 

Frequent birdnesting or kinking of

1. Wire shavings/lubricant is build-

1.

Clean cable or replace cable

wire in the gun cable.

 

ing up in the cable.

 

liner.

 

2.

Cable liner is too large for wire

2.

Install the smallest possible liner

 

 

size.

 

which is specified for the wire

 

 

 

 

being used (i.e. use a .052-1/16

 

 

 

 

liner instead of a 1/16-5/64 liner

 

 

 

 

when welding with 1/16” diameter

 

 

 

 

wire.

 

3.

Mechanical resistance to wire

3.

If using a reverse bend gun tube,

 

 

feeding is too large.

 

try welding with a non reverse

 

 

 

 

bend product.

 

 

 

 

Frequent occurrence of contact tip

1. Improper welding parameters or

1.

See welding wire literature for

burnback.

 

technique (example: ESO is too

 

proper settings.

 

 

short).

 

 

 

2.

Wire may be feeding intermittent-

2. See symptoms on intermittent or

 

 

ly.

sluggish wire feed.

 

 

 

Poor weld bead appearance.

1. Improper electrode polarity.

1. Reconnect machine’s welding out-

 

 

 

put to proper electrode polarity.

 

2.

Improper welding parameters or

2. See welding wire literature for

 

 

technique.

proper settings.

 

 

 

 

Wire feeder runs or begins feeding

1. Defective trigger (contacts closed

1.

Replace trigger assembly.

wire without pulling the gun trigger.

 

or dirty).

 

 

 

2.

Defective (closed) trigger circuit

2.

See machine’s instruction manu-

 

 

in the welding machine.

 

al.

 

3.

Trigger lead(s) inside gun cable

3.

Damaged control leads along

 

 

are shorted together or commonly

 

cable; repair if possible.

 

 

shorted to either welding or

 

Otherwise, replace gun cable.

 

 

accessory switch circuits.

 

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact your Local Lincoln Authorized Field Service Facility for technical troubleshooting assistance before you proceed.

K126-10, K126-11 AND K126-12 INNERSHIELD® PRO

Page 21
Image 21
Lincoln Electric K126-12, K126-11, K126-10 manual TROUbLESHOOTING