Therma-Stor Products Group XT150H owner manual 3H Intermittent or Programmed Ventilation

Page 16

FOR HVAC INSTALLER ONLY AND HOMEOWNER

The ventilation indicator “O” will be displayed whenever

the unit is ventilating. The fan operation indicator “O” will also be lit.

There are three damper operation modes, “OPEN – hold,” “CLOSED – hold” and “PROGRAM” (denoted by “ON TIME”

“OFF TIME.” Refer to section 3.8). With the damper in the “OPEN – hold” mode, the damper will be open and the fan of the system will be operating in order to introduce fresh air into the space. Use this mode for continuous fresh air ventilation. The fan is always on when the damper is open. When in “CLOSED

hold” mode, the damper will not open and the system will not ventilate.

When in the “program” mode, the control will operate the damper and fan (ventilate) according to the programmed ventilation schedule (See Section 3.8).

To set the damper operation:

1.Press the “VENT” button. The current setting will begin to flash on the display. Release the button.

2.Press the “VENT” button again to toggle between “open,” “closed” and “program.”

3.Leave the control alone for 10 seconds to select the indicated damper mode and return to “home.”

5.3H Intermittent or Programmed Ventilation

There are two programs available for ventilation Monday through Friday. There are also two programs for Saturday and Sunday. No other choice of days is available.

Each program has:

A “START” time of day when the ventilation schedule begins.

An “OPEN FOR” duration for the amount of time the damper stays open in 5 minute intervals, from 0 to 60.

A “CLOSED FOR” duration which closes the vent for a specified time in 5 minute intervals from 0 to 60.

Example:

1.Press “program enter” button. The following menu appears:

2.Using the up/down RH buttons, select “program.” The following menu appears:

You can select from:

“MON-FRI”or “SAT-SUN” for separate weekday/weekend schedules or “MON-SUN”which gives you equal weekday/ weekend schedules.

Menu when you select “MON-FRI”or SAT-SUN”:

The system will operate the ventilation function according to the current ventilation program. The control needs to be programmed to turn the ventilation function on and off at the desired intervals. This is done by programming the ventilation timer.

1.Enter the starting time for weekdays using the up/down RH keys to change the time.

16

Ultra-Aire XT150H Installer’s & Owner’s Manual

Image 16
Contents Fresh Air Ventilation 4026480 Serial No DehumidificationAir Filtration Table of Contents Safety Precautions Safety PrecautionsFor Hvac Installer only SpecificationsInstallation Intended Application for Ultra-Aire XT150HCondensate Water Removal Ducting 4A Installing Duct Collars4B Ducting for Dehumidification 4C Ducting for Fresh Air Outside air is filtered before entering the buildingControls Quiet InstallationNoise Abatement Humidity Control Adjustment Fan/Filter SwitchVentilation Timer 1E DEH 3000 Digital Control with Fresh Air and Damper4C Automatic or Manual Mode 4A Setting the Time4B Ventilation Schedule Control Part No 2B Wiring 2A Install InstructionsDEH 3000 Digital Control Installation Instructions For Hvac Installer and Homeowner Dehumidifier lockout/activation AC sensor featureAuxiliary relay operation Disengage A/C during dehumidification2F Testing For Hvac Installer only and Homeowner2E Location 3B Setting 3C On/Off Setting3D Setting Clock Time 3E Setting Relative Humidity Setpoint3F Fan Setting and Operation Operation3H Intermittent or Programmed Ventilation 3I Temperature Cutout Programming 3J Default SettingsService MaintenanceTroubleshooting Impeller Fan Replacement Refrigerant Charging6A Checking Compressor Motor Circuits Compressor/Capacitor Replacement6B Replacing a Burned Out Compressor Remote Controls Electric Schematics of the Ultra-Aire XT150H Pictorial Electrical Diagrams of Ultra-Aire XT150H Service Parts List Ultra-Aire XT150H Ultra-Aire XT150HOptional Parts List Ultra-Aire XT150H AccessoriesDoor Install Door and Collar AssemblyCollar Install ULTRA-AIRE XT150H Dehumidifier Limited Warranty PO Box 8680 Madison, WI Phone 608-222-5301 Fax