Therma-Stor Products Group XT150H owner manual Safety Precautions

Page 3

SAFETY PRECAUTIONS

1. Safety Precautions

Read the installation, operation and maintenance instructions carefully before installing and operating this device. Proper adherence to these instructions is essential to obtain maximum benefit from your Ultra-Aire XT150H indoor air quality system.

READ AND SAVE THESE INSTRUCTIONS

The device is designed to be installed INDOORS IN A SPACE THAT IS PROTECTED FROM RAIN AND FLOODING.

Install the unit with space to access the back or side panels for maintenance and service. DO NOT INSTALL UNIT WITH THE SERVICE PANELS INACCESSIBLE.

Avoid directing the discharge air at people, or over the water in pool areas.

If used near a pool or spa; be certain there is NO chance the unit could fall into the water, be splashed and that it is plugged into a

GFI GROUND FAULT INTERRUPT OUTLET.

DO NOT use the device as a bench or table.

DO NOT place the device directly on structural members. Provide vibration isolation in order to minimize operational vibration and/or noise.

A drain pan MUST be placed under the unit if installed above a living area or above an area where water leakage could cause damage

3

Ultra-Aire XT150H Installer’s & Owner’s Manual

Image 3
Contents 4026480 Serial No Dehumidification Fresh Air VentilationAir Filtration Table of Contents Safety Precautions Safety PrecautionsIntended Application for Ultra-Aire XT150H For Hvac Installer onlySpecifications InstallationDucting 4A Installing Duct Collars Condensate Water Removal4B Ducting for Dehumidification Outside air is filtered before entering the building 4C Ducting for Fresh AirQuiet Installation ControlsNoise Abatement 1E DEH 3000 Digital Control with Fresh Air and Damper Humidity Control AdjustmentFan/Filter Switch Ventilation Timer4A Setting the Time 4C Automatic or Manual Mode4B Ventilation Schedule Control Part No 2A Install Instructions 2B WiringDEH 3000 Digital Control Installation Instructions Disengage A/C during dehumidification For Hvac Installer and HomeownerDehumidifier lockout/activation AC sensor feature Auxiliary relay operationFor Hvac Installer only and Homeowner 2F Testing2E Location 3E Setting Relative Humidity Setpoint 3B Setting3C On/Off Setting 3D Setting Clock TimeOperation 3F Fan Setting and Operation3H Intermittent or Programmed Ventilation 3J Default Settings 3I Temperature Cutout ProgrammingMaintenance ServiceTroubleshooting Refrigerant Charging Impeller Fan ReplacementCompressor/Capacitor Replacement 6A Checking Compressor Motor Circuits6B Replacing a Burned Out Compressor Remote Controls Electric Schematics of the Ultra-Aire XT150H Pictorial Electrical Diagrams of Ultra-Aire XT150H Ultra-Aire XT150H Service Parts List Ultra-Aire XT150HAccessories Optional Parts List Ultra-Aire XT150HDoor and Collar Assembly Door InstallCollar Install ULTRA-AIRE XT150H Dehumidifier Limited Warranty PO Box 8680 Madison, WI Phone 608-222-5301 Fax