Therma-Stor Products Group XT150H 1E DEH 3000 Digital Control with Fresh Air and Damper

Page 8
Figure 4
Fan/Filter Switch
Figure 3:
Humidity Control
Adjustment Knob

FOR HVAC INSTALLER ONLY

Ventilation Timer/Humidity Control Panel (P/N 4024125) (Figure 2, p.7)

4.6D Ventilation Timer and Humidity Control WITH Fresh Air AND Motorized Damper

DEH 3000 Digital Control (P/N 4024539) (Figure 1, p.10)

4.6E Digital Controller WITH Fresh Air AND Damper

4.6F Digital Controller WITHOUT Fresh Air

4.1A Humidity/Fan Control Panel WITHOUT Fresh Air Ventilation or Damper

The humidity/fan control panel automatically controls the humidity of the living space. The humidity/fan control panel contains an adjustable humidity control and a fan switch. The panel has a cover that must remain open to the air within the living space for accurate humidity sensing. When the fan switch is in the “ON” position, air will be continually filtered and circulated throughout the home. For humidity control operation refer to section 4.2.

4.1B Humidity/Fan Control Panel WITH Fresh Air Ventilation and WITHOUT Damper

The humidity/fan control panel automatically controls the humidity of the living space. The humidity/fan control panel contains an adjustable humidity control and a fan switch. The panel has a cover that must remain open to the air within the living space for accurate humidity sensing. Outside air is continually introduced whenever fan is “ON.” Manual operation of fan filter switch controls outside air ventilation. Since the fan operates whenever the Ultra- Aire XT150H is dehumidifying outside air will also be introduced. For humidity control operation refer to section 4.2.

4.1C Humidity/Fan Control Panel WITH Fresh Air Ventilation AND Damper

In this configuration, a motorized damper has been installed in the fresh air duct. When the fan/filter switch is in the “OFF” position, the damper is closed. The Ultra-Aire XT150H will then circulate and dehumidify air to provide humidity control.

When the fan/filter switch is in the “ON” position, the motorized damper will open and the fan will run, introducing outside air. The unit may or may not be dehumidifying in the ventilation mode, depending on the humidity control setting. See Section 4.2 for humidity control operation.

4.1D Ventilation Timer and Humidity Control WITH Fresh Air AND Motorized Damper

Refer to sections 4.7 through 4.9C.

4.1E DEH 3000 Digital Control WITH Fresh Air AND Damper

Refer to Section 5.

4.1F DEH 3000 Digital Control WITHOUT Fresh Air

Refer to Section 5.

4.2 Humidity Control Adjustment

Set the humidity control to the desired humidity level for the home. Turning the knob clockwise results in a drier setting. See the back

of the control panel cover for set points. The dehumidifier will run continuously until the relative humidity (RH) is reduced to the humidity control dial setting. Setting the humidity control to lower RH levels will NOT increase the dehumidification rate; the unit will simply run longer to reduce the RH to the setting. The Ultra-Aire XT150H unit (and

refrigerant-based dehumidifiers in general) will reduce a warm space’s RH to a lower level than that of a cool space. Therefore there is no benefit to set the humidity control to excessively low levels in cool rooms; doing so will result in long periods of ineffective dehumidifier run time. Settings below 45% are not recommended.

4.3 Fan/Filter Switch

Turning ON the fan/filter switch will cause the Ultra-Aire XT150H fan to run continuously, whether the Ultra-Aire XT150H is dehumidifying or not. This function is desirable if the unit is used for air circulation and filtration to achieve maximum indoor air quality. When the switch is ON; air will be

constantly filtered through the Ultra-Aire XT150H and circulated throughout the house. When the switch is OFF the fan will operate only when the humidity control calls for dehumidification or when the ventilation timer calls for ventilation.

4.4 Ventilation Timer

The ventilation timer controls the fan and the motorized fresh air damper. When the ventilation timer is activated, the Ultra- Aire XT150H will circulate the indoor air, and bring in fresh air from outside. The ventilation timer should be set for the required ventilation of the residence. The home should be ventilated with fresh air as suggested by applicable codes and standards or as required by the homeowner. The ventilation timer is an electronic timer that displays the current time. This timer has battery backup, so it will not require resetting after a power outage. Following

a prolonged power outage the display of the timer will flash on and off indicating a power outage has occurred. The one-minute time increments of the ventilation timer allow you to program the ventilation of your home to fit your schedule.

Humidity/Fan Control Panel

Ventilation Timer & Humidity

P/N 4024155

Control Panel • P/N 4024125

8

Ultra-Aire XT150H Installer’s & Owner’s Manual

Image 8
Contents Air Filtration 4026480 Serial No DehumidificationFresh Air Ventilation Table of Contents Safety Precautions Safety PrecautionsFor Hvac Installer only SpecificationsInstallation Intended Application for Ultra-Aire XT150H4B Ducting for Dehumidification Ducting 4A Installing Duct CollarsCondensate Water Removal 4C Ducting for Fresh Air Outside air is filtered before entering the buildingNoise Abatement Quiet InstallationControls Humidity Control Adjustment Fan/Filter SwitchVentilation Timer 1E DEH 3000 Digital Control with Fresh Air and Damper4B Ventilation Schedule 4A Setting the Time4C Automatic or Manual Mode Control Part No DEH 3000 Digital Control Installation Instructions 2A Install Instructions2B Wiring For Hvac Installer and Homeowner Dehumidifier lockout/activation AC sensor featureAuxiliary relay operation Disengage A/C during dehumidification2E Location For Hvac Installer only and Homeowner2F Testing 3B Setting 3C On/Off Setting3D Setting Clock Time 3E Setting Relative Humidity Setpoint3F Fan Setting and Operation Operation3H Intermittent or Programmed Ventilation 3I Temperature Cutout Programming 3J Default SettingsTroubleshooting MaintenanceService Impeller Fan Replacement Refrigerant Charging6B Replacing a Burned Out Compressor Compressor/Capacitor Replacement6A Checking Compressor Motor Circuits Remote Controls Electric Schematics of the Ultra-Aire XT150H Pictorial Electrical Diagrams of Ultra-Aire XT150H Service Parts List Ultra-Aire XT150H Ultra-Aire XT150HOptional Parts List Ultra-Aire XT150H AccessoriesCollar Install Door and Collar AssemblyDoor Install ULTRA-AIRE XT150H Dehumidifier Limited Warranty PO Box 8680 Madison, WI Phone 608-222-5301 Fax