Carrier 48HJ015-025 installation instructions Base Unit Dimensions, 48HJ015,017

Page 5

UNIT

MAXIMUM SHIPPING WEIGHT

48HJ

Lb

Kg

D015

1920

871

E015

1940

880

E017

2310

1048

 

 

 

 

 

UNIT

 

 

 

 

 

DIMENSIONS

 

 

 

 

 

 

 

 

 

 

 

 

X

 

 

 

 

 

Y

 

 

 

 

 

 

 

48HJ

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Ft-in.

 

mm

 

Ft-in.

 

 

mm

 

 

 

 

 

D015

 

 

3-2

 

965

 

 

4-0

 

 

1219

 

 

 

 

 

E015

 

 

3-2

 

965

 

 

4-0

 

 

1219

 

 

 

 

 

E017

 

 

3-73¤8

 

1102

 

 

3-65¤8

 

1083

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

UNIT

 

 

 

 

 

 

WEIGHT OF CORNER*

 

 

 

 

 

 

A

 

 

 

B

 

C

 

 

 

 

 

D

48HJ

 

 

 

 

 

 

 

 

 

 

 

 

 

Lb

 

 

Kg

 

Lb

 

Kg

 

Lb

 

 

Kg

 

Lb

 

Kg

D015

 

365

 

166

 

360

 

163

 

373

 

169

 

540

 

245

E015

 

372

 

169

 

363

 

165

 

377

 

171

 

547

 

248

E017

 

509

 

231

 

506

 

230

 

475

 

216

 

519

 

235

 

 

 

 

 

 

 

 

 

 

*Weights are for unit only and do not include options or crating.

 

 

NOTES:

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.

Dimensions in ( ) are in millimeters.

 

 

 

 

 

 

 

2. Center of gravity.

3. Direction of air¯ow.

4.Ductwork to be attached to accessory roof curb only.

5.Minimum clearance:

a.Rear: 7 -0 (2134) for coil removal. This dimension can be reduced to 4 -0 (1219) if conditions permit coil removal from the top.

b.Left side: 4 -0 (1219) for proper condenser coil air¯ow.

c.Front: 4 -0 (1219) for control box access.

d.Right side: 4 -0 (1219) for proper operation of damper and power exhaust (if so equipped).

e.Top: 6 -0 (1829) to assure proper condenser fan operation.

f.Local codes or jurisdiction may prevail.

6.With the exception of clearance for the condenser coil and the damper/ power exhaust as stated in Note No. 5, a removable fence or barri- cade requires no clearance.

7.Dimensions are from outside of corner post. Allow 0 -5¤16(8) on each side for top cover drip edge.

Fig. 4 Ð Base Unit Dimensions, 48HJ015,017

5

Image 5
Contents Installation ContentsSafety Considerations ``A ``B ``C Accessory Curb DescriptionPackage no Height 50DP900211Unit Dimension aUnit Maximum Shipping Weight Physical Data Base Unit Dimensions, 48HJ015,017 Base Unit Dimensions, 48HJ025 Air Distribution Ð Through-the-Bottom 48HJ017 and 025 Shown Combustion Fan Housing Location Electrical Data Make Electrical ConnectionsEquip GND48HJD015 All 48HJD025, HJE015 HJE017 Make Outdoor-Air Inlet AdjustmentsUnit Voltage Unit Economizer Motor Control Module Location START-UP Accessory Field-Installed Economizer AdjustFiop Ð Fan Performance Data, 48HJ015, 208/230, 460-V UnitsAirflow Ð Fan Performance Data, 48HJ015, 575-V Units Fan Performance Data, 48HJ017 Units Unit 48HJ Minimum CFM Maximum CFM Fan Performance Data, 48HJ025 UnitsAir Quantity Limits Base Unit Operation Accessory/FIOP Economizer Static Pressure in. wgUnit CFM Economizer Pressure DropLubrication ServiceManufacturer Lubricant Evaporator Fan, 48HJ015 UnitsEvaporator Fan, 48HJ017,025 Units Condenser-Fan Adjustment Belt Tension Adjustment Ð To adjust belt tensionHigh and Low Outdoor-Air Temperature Economizer Checkout ProceduresGas Valve Adjustment Pilot AdjustmentMain Burner Removal Protective DevicesTypical Wiring Schematic 48HJ025 Shown Typical Wiring Schematic 48HJ025 Shown Typical Component Arrangement 48HJ025 Shown IFM AHAIFR CLOPage Page Packaged Service Training Page PRE-START-UP START-UP Checklist

48HJ015-025 specifications

The Carrier 48HJ015-025 is a distinguished series of rooftop packaged units renowned for their efficient performance and reliability in light commercial applications. Designed for a variety of indoor environments, these units are engineered to provide efficient heating and cooling solutions, making them suitable for retail spaces, offices, and other commercial buildings.

One of the main features of the Carrier 48HJ series is its advanced scroll compressor technology, which enhances the overall efficiency of the systems. This type of compressor is known for its durability and quiet operation, providing consistent temperature control while minimizing energy consumption. The use of a scroll compressor contributes to a higher Seasonal Energy Efficiency Ratio (SEER) and Heating Seasonal Performance Factor (HSPF), making these units a smart choice for energy-conscious businesses.

Additionally, the 48HJ series incorporates a multi-speed indoor blower that allows for precise airflow control. This feature ensures optimal indoor comfort by adjusting the air distribution based on the specific heating or cooling needs of the space. The ability to adapt to varying load conditions enhances efficiency and reduces energy wastage.

Another noteworthy characteristic of the Carrier 48HJ015-025 is its robust construction. Built with galvanized steel, the units are designed to withstand harsh environmental conditions, ensuring longevity and minimal maintenance requirements. The powder-painted finish offers corrosion resistance, contributing to the unit’s durability over time.

The series also integrates advanced controls for ease of operation. The user-friendly thermostat enables precise temperature management and can be programmed according to the specific needs of the facility. Moreover, compatibility with Building Management Systems (BMS) facilitates seamless integration into existing infrastructure, enabling remote monitoring and enhanced operational efficiency.

In terms of environmental considerations, the Carrier 48HJ series utilizes R-410A refrigerant, which is known for its reduced impact on the ozone layer compared to older refrigerants. This commitment to sustainability aligns with modern environmental standards and regulations.

Overall, the Carrier 48HJ015-025 stands out as a versatile and efficient rooftop packaged unit, perfect for varying commercial applications. Its combination of advanced technology, reliability, and user-focused design makes it a prominent choice for businesses seeking optimized climate control solutions while ensuring sustainability and energy efficiency.