White Rodgers F95-391 operating instructions Adjustable Humidity Display RH, Cmft

Page 9

minutes (or 3 hours, 45 minutes if

EMR

ON L

is selected). The maximum time in

 

cooling and heat pump applications is 3 hours and 45 minutes. Cooling or heat pump applications start earlier because it takes longer to reach the desired temperature. This feature also minimizes the use of the auxiliary stages if conditions are such that the compressor stages are adequate to reach the desired setpoint.

To select or deselect this feature, refer to the CONFIGURATION section (page 4, step 2).

Adjustable Humidity Display (RH)

(User Menu step 3) The room

humidity display can be adjusted to read higher or lower by following the configuration menu and adjusting the humidity to a higher or lower value. The thermostat is calibrated at the factory to display a very accurate room humidity, but due to various

conditions and/or personal preference,

 

you may wish to adjust the thermostat

 

display higher or lower (up to +/-

 

20%). For example, if the thermostat

 

displays room humidity of 40% but

 

you want it to display 43% you can

 

adjust it. To adjust, refer to the

 

CONFIGURATION

section

(page 4,

step 3).

 

 

Programmable Automatic Humidity Reduction (DRY)

(User Menu step 4)

This feature automatically lowers humidity setting when the outside temperature drops. This is to prevent the interior windows/walls from reaching the dew point where water condenses on surfaces. To achieve automatic humidity reduction, the thermostat lowers the humidity when furnace cycles are long. When the furnace runs shorter cycles, it increases

7

humidity. For suggested settings see table below.

Programmable Dehumidification

Optimal Comfort Mode (OPTM

CMFT)

(User Menu step 5)

When turned on

this feature automatically reduces

 

indoor humidity during calls for

 

cooling if humidity is 2% above

 

setting. Humidity is set by pressing the

 

Humidity button when in the appropri-

 

ate mode, in this case Cooling, and

 

pressing the

or

buttons to

set desired humidity (range 40 to 95) level followed by pressing Run Program. This dehumidification

feature uses less energy by maintaining temperature and dehumidifying only when a call for Cooling is required.

Configuration

Image 9
Contents SeriesTM Easy, Menu-Driven Set-Up Programming Thermostat Buttons OrientationTime HeatPrgm Large Lighted LCD DisplayOFF DisplaysIntroduction Introduction ConfigurationTo enter the menu, press ConfigurationOne shot option Adjustable Temperature Display Configuration Menu FeaturesRecovery EMR Selectable Energy ManagementProgrammable Dehumidification Optimal Comfort Mode Optm Adjustable Humidity Display RHProgrammable Automatic Humidity Reduction DRY CmftOptm Dhum Cool Fast Optional Remote TemperatureSense EVEKeypad Lockout Menu Outdoor Temperature SenseAllows only TotalTempo Rary Program OverrideManual Operation ProgrammingCool MONAgain to copy COPY, and allButton ProgramMON 78 F 25 C Day Personal Heat Program Schedule Day Personal Cool Program Schedule Program RUN FeaturesAutomatic Heat/Cool Changeover Programmable Vacation Time/ Temperature OperationHold UserFlashing. Press Thermostat Startup Up After Power LossKeypad Lockout LockoutGram Service Button MenuCompressor Short Cycle Protection Show either REM PAD TIME, REMSet Air Set Humidifier Maintenance ReminderAir Filter Change-Out Indicator Humidifier Maintenance IndicatorService Chng FltrTime SET Filter TimeTime Back ProgramTo the CONFIGURATIONsection page 4, step Adjustable Humidity DisplayPress Time FWD or Time Back Programmable Automatic Humidity ReductionTime Back Humidifier Control and MonitoringTime FWD TempOFF FAN on1F95-391 HEAT, OFF, COOL, or Auto is displayedChck PAD Chck PAD isHumd MX Occurred ContOwn to accept the change Heat pump thermostat? AuxResetting Thermostat TroubleshootingSymptom Possible Cause Corrective Action WillRaise temperature above room temperature Ture below room temperatureButton to Cool and lower tempera Person can instruct you on how to test the Heat/Cool System for correct operation. If the system operatesCorrectly, replace the thermostat Symptom Possible Cause Corrective Action Troubleshooting Index Page Part no -6528B

F95-391 specifications

The White Rodgers F95-391 is a versatile and advanced thermostat designed for residential and light commercial applications, providing optimal temperature control and energy efficiency. Featuring a sleek design, the F95-391 integrates seamlessly into various home and business environments, ensuring both functionality and aesthetics are addressed.

One of the main features of the F95-391 is its ability to accommodate multiple heating and cooling systems. It supports up to four stages of heating and two stages of cooling, making it suitable for complex HVAC setups. This flexibility allows for precise temperature management, contributing to enhanced comfort and energy savings.

The F95-391 is equipped with a user-friendly interface that includes a large, easy-to-read display. Users can access current temperature readings, set their desired temperature, and manage programming functions effortlessly. The device also offers a variety of programming options, including 7-day programmable scheduling. This means users can customize heating and cooling settings according to their daily routines, helping to minimize energy use during unoccupied hours.

Advanced technologies are integrated into the White Rodgers F95-391, including adjustable temperature sensitivity and automatic recovery features. The adjustable temperature sensitivity allows users to fine-tune how quickly the system responds to temperature changes, promoting energy efficiency. The automatic recovery function ensures that the home reaches the desired temperature by the time scheduled programming begins, enhancing comfort without unnecessary energy consumption.

Another noteworthy characteristic is its compatibility with Wi-Fi, allowing remote access via smartphones and tablets. This connectivity feature enables users to monitor and adjust their thermostat settings from anywhere, making it convenient to manage home temperature on the go. By leveraging smart technology, homeowners can optimize their energy consumption even when they are not present.

The F95-391 also includes features such as a filter change reminder and HVAC system diagnostics. These tools help users maintain their heating and cooling systems effectively, reducing the risk of system failures and extending the lifespan of their equipment.

In summary, the White Rodgers F95-391 thermostat stands out for its programmability, advanced technologies, and user-friendly features. Ideal for those seeking an efficient and modern solution to temperature management, the F95-391 combines comfort with energy savings, making it a valuable addition to any space.