Heat & Glo LifeStyle EXCLAIM-42H-C Assemble the Chimney Sections, Install the Ceiling firestops

Page 22

C. Assemble the Chimney Sections

Attach either a straight chimney section or an offset to the top of the fireplace (depending on your installation require- ment). Chimney sections are locked together by pushing downward until the top section meets the stop bead on the lower section.

The inner flue is placed to the inside of the flue section below it. The outer casing is placed outside the outer casing of the chimney section below it. See Figure 5.4.

Figure 5.4 Assembling Chimney Sections

Note: Inner flue and outer liner sections cannot be disas- sembled once locked together. Plan ahead to ensure the proper installation height is achieved with the selected chimney components.

WARNING

Fire Risk

Do NOT install substitute or damaged chimney components.

MUST use chimney system described in this manual.

NO OTHER chimney components may be used.

Substitute or damaged chimney components may impair safe operation.

D. Install the Ceiling firestops

Mark and cut an opening in the ceiling for the ceiling firestop being used. See Figure 5.5.

Frame the opening with the same size lumber used in the ceiling joists.

Install the ceiling firestop.

Note: The ceiling firestop MUST be nailed to the bottom of the ceiling joists EXCEPT when the space above is uninsulated and the attic insulation shield is not being used (see Figure 5.5). When the attic insulation shield is used the ceiling firestop may be above or below the joist of an insulated ceiling.

ROOM ABOVE (non-insulated ceiling)

B

A

Ceilng firestop from

bottom

ATTIC ABOVE (insulated ceiling)

Ceiling firestop from

When attic insulation

top

shield not used

Note: Use same dimensional lumber for framing ceiling firestop and joists.

 

A

 

 

B

Catalog #

in.

 

mm

in.

 

mm

FS538

17

 

432

17

 

432

FS540

17

 

432

26

 

660

Figure 5.5 Installing the Ceiling Firestop

Note: You must provide support for the pipe during con- struction and check to be sure inadvertent loading has not dislodged the chimney section from the fireplace or at any chimney joint.

CAUTION

Ceiling firestops must be used at ceiling/floor.

Chase construction requires ceiling firestops at each floor or every 10 ft (3.05 m) of clear space.

Use same dimensional lumber as joists.

Ceiling firestop slows spread of fire and reduces cold air infiltration.

22

Heat & Glo • EXCLAIM-42C4013-094 Rev I • 10/06

Image 22
Contents EXCLAIM-42H-C EXCLAIM-42T-C Fire RiskGrate Listing Label Information/LocationNumber Table of Contents Appliance Certification Listing and Code ApprovalsNot intended for use as a primary heat source Negative Pressure Design and Installation ConsiderationsGetting Started Asphyxiation RiskMarginal Location Typical Fireplace System Inspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Framing and Clearances Selecting Fireplace LocationClearances Clearances to Combustible MaterialsSidewalls/Surrounds Frame the Fireplace¨E. Construct the Chase Chimney RequirementsSharp Edges Asphyxiation Risk Installation of FireplaceInstall the Outside Air Kit Risk of Smoke SpillageFt min. from top of uppermost chimney section to air inlet Install the Refractory Secure the FireplaceGrate Brackets Grate Bracket Place the Protective Metal Hearth Strips Level the FireplaceChimney Assembly Height of Chimney Components Using Offsets/Returns SL406 SL412 SL418 SL436 SL448Install the Ceiling firestops Assemble the Chimney SectionsSecure the Chimney Install the Attic Insulation ShieldDouble-check the Chimney Assembly In./19 mm in lengthComplete the Enclosure Chimney TerminationInstall the Termination Cap Chase TopInstalling an ST475 Square Termination Cap Gas Log/Lighter Provisions AccessoriesGas Code, Ansi Z223.1 Finishing Hearth ExtensionMin 20 in. Min Glass Doors Finishing MaterialMantel Combustible MaterialOperating Instructions General InformationFlue Damper Outside AirClear Space Near the Fireplace FirescreenGrate Wood FuelStarting a Fire Troubleshooting Understanding Vent ProblemsDiagnostic Questions Diagnostics and Problem SolvingSolutions fireplace burns the wood too fast. What can I do? Disposal of Ashes Maintenance and Servicing the FireplaceChimney Inspection/Cleaning Firebox RefractoryClean Maintenance Task ListWhen cleaning glass door Chimney FireFireplace Dimensions Reference MaterialsFireplace Components Catalog # DescriptionChimney Components Catalog #Catalog # 14-3/4 375 mm 20 x Minimum Base Dimensions 28 X 28 with 32 X 32 with 23 XMinimum Base Dimensions 26.5 X 28 with 34 X 34 with Minimum Height InchesService Parts EXCLAIM-42-C Series Service PartsRefractory-Traditional # Description of PartRefractory-Herringbone EXCLAIM-42C QtyThis page intentionally left blank This page intentionally left blank This page intentionally left blank Warranty For Heat & GLO Fireplaces Limited WarrantyContact Information

EXCLAIM-42H-C, EXCLAIM-42T-C specifications

The Heat & Glo LifeStyle EXCLAIM-42H-C and EXCLAIM-42T-C are modern gas fireplaces designed to elevate both aesthetics and functionality in residential spaces. With a spacious viewing area and an array of innovative features, these fireplaces create a stunning centerpiece for any room while providing efficient heating and ambiance.

One of the standout characteristics of the EXCLAIM series is its sleek and contemporary design. The 42-inch size of both models makes them suitable for various settings, from cozy living rooms to expansive open-concept spaces. The clean lines and glass front enhance visibility and allow flames to be the focal point, creating a warm and inviting atmosphere.

The technology behind the Heat & Glo LifeStyle EXCLAIM fireplaces includes the advanced IntelliFire® ignition system. This feature offers both convenience and safety, as it eliminates the need for manual lighting and ensures a reliable ignition every time. Users can control the fireplace easily with a remote, smartphone app, or wall switch, allowing for seamless operation and temperature adjustment.

Energy efficiency is a hallmark of the EXCLAIM-42H-C and EXCLAIM-42T-C models. Equipped with a high-efficiency gas burner, these fireplaces provide optimal heat output while minimizing fuel consumption. The option to customize flame intensity and choose from a variety of fire media, including rocks and glass, adds unique personalization to each installation.

Another significant feature is the unique Power Venting system, which offers versatile venting options. This enables homeowners to install the fireplace in non-traditional locations without being limited by conventional venting routes. With a range of venting configurations, the EXCLAIM fireplaces can be adapted to fit various architectural layouts.

The ambient lighting system further enhances the overall visual appeal. Adjustable LED accent lights can illuminate the firebox and highlight the decorative media, allowing users to create a customized ambiance that suits different occasions and moods.

For those concerned about the environmental impact, these fireplaces emphasize clean-burning technology, producing lower emissions compared to traditional wood-burning options. Therefore, homeowners can enjoy the warmth and comfort of a fireplace while being environmentally conscious.

In conclusion, the Heat & Glo LifeStyle EXCLAIM-42H-C and EXCLAIM-42T-C models represent a perfect blend of style, efficiency, and cutting-edge technology. Their contemporary design, convenient operation, and customizable features make them an excellent choice for anyone looking to enhance their living space with a sophisticated gas fireplace.