Heat & Glo LifeStyle EXCLAIM-42T-C, EXCLAIM-42H-C Chase Top, Install the Termination Cap

Page 25

Install the Chimney Air Kit (required in Canada)

When installing the chimney air kit, follow the instructions provided with this accessory.

B. Chase Top

A metal chase top is required to seal the top of the chase around the chimney pipe. The top should include a turn- down and drip edge to prevent water from seeping into the chase. Provide a 1/8 in. (3 mm) gap around the flue pipe and slope the top downward away from the penetration. See Figure 6.4.

All seams must be caulked to prevent leaks.

A chase installation must use a chase top. Chase tops are available from your Heat & Glo dealer or may be field constructed.

Attach the chase top to the top of the chase.

Termination Cap

Install the chimney sections up through the chase enclosure. When using a TR444 Round Termination Cap, the uppermost top section of pipe must extend 6 in. (152 mm) above the top of the flashing collar to allow installation of the storm collar and termination cap. See Figure 6.5.

Minimum 1-1/2 in. (38 mm) overlap of cap over pipe

Storm Collar

2 in. (51 mm) min.

6 in. (152mm) min.

 

 

 

 

 

 

Flashing Collar

 

 

 

2 in. (51 mm) min. collar

 

 

Figure 6.5 Installing a TR11 Round Termination Cap

Caulk

2 in. (51 mm) Collar on Chase Top

Storm Collar

Slope Downward

For installations utilizing a TR442 Round Telescoping

Termination Cap, the uppermost chimney section must be

below the top of the chase top, but not more than 14-1/2 in.

(368 mm) below the top of the chase top. Minimum overlap

of chimney and termination cap must be 1-1/2 in. (38 mm).

See Figure 6.6.

Turn-down Drip Edge

Chase (Chimney)

.018 (26 ga) min. Galvanized Chase Top

Figure 6.4 Chase Top Construction

C. Install the Termination Cap

Note: To protect against the effect of corrosion on those parts exposed to the weather, the termination cap can be painted with a rust-resistant paint.

 

 

 

Storm Collar

Flashing Collar

2 in. (51 mm) min.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

14-1/2 in. (368mm) max.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Top of Pipe

 

 

 

1-1/2 in. (38 mm) min.

 

 

 

 

 

 

overlap

Figure 6.6 Installing a TR442 Round Telescoping Termination Cap

WARNING

Fire Risk

The minimum overlap of cap to pipe MUST be met or chimney may separate from cap.

Separation allows sparks, heat and embers to escape.

Heat & Glo • EXCLAIM-42C4013-094 Rev I • 10/06

25

Image 25
Contents Fire Risk EXCLAIM-42H-C EXCLAIM-42T-CGrate Listing Label Information/LocationNumber Table of Contents Appliance Certification Listing and Code ApprovalsNot intended for use as a primary heat source Getting Started Design and Installation ConsiderationsNegative Pressure Asphyxiation RiskMarginal Location Typical Fireplace System Inspect Fireplace and Components Tools and Supplies NeededFire Risk Explosion Risk Selecting Fireplace Location Framing and ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsChimney Requirements ¨E. Construct the ChaseInstall the Outside Air Kit Installation of FireplaceSharp Edges Asphyxiation Risk Risk of Smoke SpillageFt min. from top of uppermost chimney section to air inlet Secure the Fireplace Install the RefractoryGrate Brackets Grate Bracket Level the Fireplace Place the Protective Metal Hearth StripsChimney Assembly Height of Chimney Components SL406 SL412 SL418 SL436 SL448 Using Offsets/ReturnsAssemble the Chimney Sections Install the Ceiling firestopsDouble-check the Chimney Assembly Install the Attic Insulation ShieldSecure the Chimney In./19 mm in lengthChimney Termination Complete the EnclosureChase Top Install the Termination CapInstalling an ST475 Square Termination Cap Gas Log/Lighter Provisions AccessoriesGas Code, Ansi Z223.1 Hearth Extension FinishingMin 20 in. Min Mantel Finishing MaterialGlass Doors Combustible MaterialGeneral Information Operating InstructionsClear Space Near the Fireplace Outside AirFlue Damper FirescreenWood Fuel GrateStarting a Fire Understanding Vent Problems TroubleshootingDiagnostic Questions Diagnostics and Problem SolvingSolutions fireplace burns the wood too fast. What can I do? Chimney Inspection/Cleaning Maintenance and Servicing the FireplaceDisposal of Ashes Firebox RefractoryWhen cleaning glass door Maintenance Task ListClean Chimney FireReference Materials Fireplace DimensionsCatalog # Description Fireplace ComponentsCatalog # Chimney ComponentsCatalog # 14-3/4 375 mm Minimum Base Dimensions 26.5 X 28 with 34 X 34 with Minimum Base Dimensions 28 X 28 with 32 X 32 with 23 X20 x Minimum Height InchesService Parts Service Parts EXCLAIM-42-C SeriesRefractory-Herringbone # Description of PartRefractory-Traditional EXCLAIM-42C QtyThis page intentionally left blank This page intentionally left blank This page intentionally left blank Limited Warranty Warranty For Heat & GLO FireplacesContact Information

EXCLAIM-42H-C, EXCLAIM-42T-C specifications

The Heat & Glo LifeStyle EXCLAIM-42H-C and EXCLAIM-42T-C are modern gas fireplaces designed to elevate both aesthetics and functionality in residential spaces. With a spacious viewing area and an array of innovative features, these fireplaces create a stunning centerpiece for any room while providing efficient heating and ambiance.

One of the standout characteristics of the EXCLAIM series is its sleek and contemporary design. The 42-inch size of both models makes them suitable for various settings, from cozy living rooms to expansive open-concept spaces. The clean lines and glass front enhance visibility and allow flames to be the focal point, creating a warm and inviting atmosphere.

The technology behind the Heat & Glo LifeStyle EXCLAIM fireplaces includes the advanced IntelliFire® ignition system. This feature offers both convenience and safety, as it eliminates the need for manual lighting and ensures a reliable ignition every time. Users can control the fireplace easily with a remote, smartphone app, or wall switch, allowing for seamless operation and temperature adjustment.

Energy efficiency is a hallmark of the EXCLAIM-42H-C and EXCLAIM-42T-C models. Equipped with a high-efficiency gas burner, these fireplaces provide optimal heat output while minimizing fuel consumption. The option to customize flame intensity and choose from a variety of fire media, including rocks and glass, adds unique personalization to each installation.

Another significant feature is the unique Power Venting system, which offers versatile venting options. This enables homeowners to install the fireplace in non-traditional locations without being limited by conventional venting routes. With a range of venting configurations, the EXCLAIM fireplaces can be adapted to fit various architectural layouts.

The ambient lighting system further enhances the overall visual appeal. Adjustable LED accent lights can illuminate the firebox and highlight the decorative media, allowing users to create a customized ambiance that suits different occasions and moods.

For those concerned about the environmental impact, these fireplaces emphasize clean-burning technology, producing lower emissions compared to traditional wood-burning options. Therefore, homeowners can enjoy the warmth and comfort of a fireplace while being environmentally conscious.

In conclusion, the Heat & Glo LifeStyle EXCLAIM-42H-C and EXCLAIM-42T-C models represent a perfect blend of style, efficiency, and cutting-edge technology. Their contemporary design, convenient operation, and customizable features make them an excellent choice for anyone looking to enhance their living space with a sophisticated gas fireplace.