Heat & Glo LifeStyle Escape-42DVLP Install Metal Roof Flashing, Assemble and Install Storm Collar

Page 37

E. Install Metal Roof Flashing

See minimum vent heights for various pitched roofs (Figure 10.11) to determine the length of pipe to extend through the roof.

Slide the roof fl ashing over the pipe sections extending through the roof as shown in Figure 10.12.

 

 

HORIZONTAL

 

 

OVERHANG

2 FT.

20 INCHES MIN.

VERTICAL

MIN.

 

 

WALL

 

LOWEST

 

 

 

DISCHARGE

 

 

OPENING

 

GAS DIRECT VENT

 

 

TERMINATION CAP

 

 

 

 

X

 

 

12

 

 

ROOF PITCH

 

 

IS X/ 12

 

H (MIN.) - MINIMUM HEIGHT FROM ROOF

 

TO LOWEST DISCHARGE OPENING

Roof Pitch

 

H (Min.) Ft.

Flat to 6/12........................................ 1.0*

Over 6/12 to 7/12............................ 1.25*

Over 7/12 to 8/12..............................1.5*

Over 8/12 to 9/12..............................2.0*

Over 9/12 to 10/12............................. 2.5

Over 10/12 to 11/12 ......................... 3.25

Over 11/12 to 12/12 ........................... 4.0

Over 12/12 to 14/12........................... 5.0

Over 14/12 to 16/12........................... 6.0

Over 16/12 to 18/12........................... 7.0

Over 18/12 to 20/12........................... 7.5

Over 20/12 to 21/12........................... 8.0

* 3 foot minimum in snow regions

Figure 10.11 Minimum Height From Roof To Lowest Discharge

Opening

 

 

NOTICE: Failure to properly caulk the roof flashing and pipe seams may permit entry of water.

Caulk the gap between the roof fl ashing and the outside diameter of the pipe.

Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.12.

Caulk the overlap seam of any exposed pipe sections that are located above the roof line.

CAULK

Figure 10.12

F. Assemble and Install Storm Collar

CAUTION! Risk of Cuts, Abrasions or Flying Debris. Wear protective gloves and safety glasses during instal- lation. Sheet metal edges are sharp.

Connect both halves of the storm collar with two screws (see Figure 10.13).

Wrap the storm collar around the exposed pipe section closest to the roof and align brackets. Insert a bolt (provided) through the brackets and tighten the nut to complete the storm collar assembly. Make sure the collar is tight against the pipe section.

Slide the assembled storm collar down the pipe section until it rests on the roof fl ashing (see Figure 10.14).

Caulk around the top of the storm collar (see Figure 10.15).

Figure 10.13 Assembling the Storm Collar

Figure 10.14 Assembling the Storm Collar Around the Pipe

Heat & Glo • Escape-42DV2052-900 Rev. Y • 11/11

37

Image 37
Contents What to do if you smell gas ModelHomeowner Reference Information CongratulationsUser Guide Table of ContentsTroubleshooting Appliance SetupFinishing Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Requirements for the Commonwealth of Massachusetts Installation of Carbon Monoxide DetectorsOperating Instructions User Guide Gas Fireplace SafetyYour Fireplace Wall Controls and Wall Switches Fixed Glass AssemblyClear Space Decorative Doors and FrontsFinal inspection by Lighting Instructions IPIAfter Fireplace is Lit Frequently Asked QuestionsMaintenance and Service Gasket Seal and Glass Assembly Inspection Maintenance Tasks-Qualified Service TechnicianVenting LogsIPI Pilot Flame Patterns Burner Ignition and OperationTypical Appliance System Getting StartedTools and Supplies Needed Design and Installation ConsiderationsInspect Appliance and Components Selecting Appliance Location Framing and ClearancesClearances Constructing the Appliance ChaseCombustible Mantels Mantel and Wall ProjectionsCombustible Mantel Legs or Wall Projections Fireplace sitting on combustible surface Hearth ExtensionVent Termination Minimum Clearances Termination LocationsPorch, deck or balcony Covered Alcove ApplicationsApproved Pipe Vent Information and DiagramsVent Table Key Use of ElbowsTwo Elbows Vent Diagrams Top Vent Horizontal Termination One ElbowH1+ H2 Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft .2 m Max Ht Max Top Vent Vertical Termination Three ElbowsPipe Clearances to Combustibles Vent Clearances and FramingWall Penetration Framing Combustible Wall PenetrationPipe DVP Install the Ceiling FirestopInstalling the Optional Heat-ZoneGas Kit  Install Attic Insulation ShieldFlat Ceiling Installation Vaulted Ceiling InstallationAppliance Preparation Removing Non-combustible Facing Ma- terial AssemblySecuring and Leveling the Appliance Material Installing Non-combustible Facing MaterialAttach Vent to the Firebox Assembly Installing Vent PipeAssemble Vent Sections Assemble Pipe SectionsSecure the Vent Sections Assemble Slip SectionsDisassemble Vent Sections Rotate Seams for DisassemblyAssemble and Install Storm Collar Install Metal Roof FlashingHeat Shield Requirements for Horizontal Termination Install Vertical Termination CapDVP-HPC1 DVP-HPC2 Install Horizontal Termination CapFuel Conversion Gas InformationGas Pressure Gas ConnectionOptional Accessories Requirements Wiring RequirementsIntelliFire Ignition System Wiring Electrical InformationDetail a Electrical Service and Repair Junction Box Installation Finishing To install the Splatter GuardSplatter Guard Facing Material Finishing Materials Requirements Noncombustible Facing DiagramAppliance Setup Install the Log Assembly Log Set Assembly LOGS-ESCAPE42 Models Escape-42DVStep LOG #2 SRV2012-082 Two LOG #1 SRV2012-081 ThreeLOG #4 SRV2012-084 LOG #3 SRV2052-083LOG #5 SRV2012-085 LOG #7 SRV2012-087 LOG #6 SRV2052-086LOG #8 SRV2012-088 Final StepAir Shutter Setting Install the MeshAir Shutter Settings Symptom Possible Cause Corrective Action TroubleshootingIntelliFire Ignition System Ues to spark, and main Reference Materials Appliance Dimension DiagramDVP-AS2 Vent Components DiagramsDVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 RF6M RF12M 12-1/2 Description Part Number Optional Wire HarnessContact Information

Escape-42DVLP, Escape-42DV specifications

The Heat & Glo LifeStyle Escape-42DV and Escape-42DVLP are innovative direct vent gas fireplaces designed to enhance the ambiance of any living space while providing efficient heating. These models represent the perfect blend of modern technology, aesthetic appeal, and user-friendly features, making them popular choices for homeowners seeking a stylish and functional heating solution.

One of the standout features of the Heat & Glo LifeStyle Escape-42DV is its impressive design. With a large viewing area, the fireplace allows for a mesmerizing display of flames, creating a focal point in any room. The clean, contemporary lines of the unit fit seamlessly into various décor styles, whether modern, traditional, or transitional. Furthermore, the Escape-42DVLP version, designed for those desiring a low-profile option, ensures that homeowners can enjoy the aesthetics of a fireplace without overwhelming the space.

Both models boast advanced technologies that enhance performance and usability. The Direct Vent System allows for efficient combustion by drawing air from outside the home and expelling exhaust gases through a sealed vent. This ensures optimal efficiency and makes them suitable for tight, energy-efficient homes. Additionally, these fireplaces include a Status Light feature that indicates when the fireplace is operating, ensuring peace of mind for users.

The LifeStyle Escape series also excels in customizability. Homeowners can choose from various log sets, decorative media, and tile surrounds, allowing them to tailor their fireplace to match personal styles and preferences. The IntelliFire app provides a convenient way to control the fireplace from a smartphone, featuring options for remote ignition, programmable timers, and flame height adjustments, putting users in complete control of their heating experience.

Safety is paramount, and the Heat & Glo LifeStyle Escape models come equipped with an advanced safety barrier to prevent accidental contact with the hot glass surface, making them family-friendly options. Moreover, their low emissions and high-efficiency ratings contribute to environmentally responsible heating.

In summary, the Heat & Glo LifeStyle Escape-42DV and Escape-42DVLP models combine striking aesthetics, efficient heating technologies, and user-centric features. They offer a modern solution for anyone looking to elevate their home's warmth and sophistication, making them a smart investment for comfort and style.