G. Install Vertical Termination Cap

Attach the vertical termination cap by sliding the inner collar of the cap into the inner fl ue of the pipe section while placing the outer collar of the cap over the outer fl ue of the pipe section.

Secure the cap by driving three self-tapping screws (supplied) through the pilot holes in the outer collar of the cap into the outer fl ue of the pipe (see Figure 10.15).

TERMINATION CAP

(1 of 3)

STORM

COLLAR

SCREWS

CAULK

Figure 10.15

H.Heat Shield Requirements for Horizontal Termination

WARNING! Risk of Fire! To prevent overheating and fire, heat shields must extend through the entire wall thick- ness.

DO NOT remove the heat shields attached to the wall shield firestop and the horizontal termination cap (shown in Figure 10.16).

Heat shields must overlap 1-1/2 in. (38 mm) mini- mum.

There are two sections of the heat shield. One section is factory-attached to the wall shield fi restop. The other section is factory-attached to the cap. See Figure 10.16.

If the wall thickness does not allow the required 1-1/2 in. (38 mm) heat shield overlap when installed, an extended heat shield must be used.

If the wall thickness is less than 4 in. (102 mm), the heat shields on the cap and wall shield fi restop must be trimmed. A minimum 1-1/2 in. (38 mm) overlap MUST be maintained.

Use an extended heat shield if the fi nished wall thickness is greater than 7-1/4 in. (184 mm).

The extended heat shield may need to be cut to length maintaining suffi cient length for a 1-1/2 in. (38 mm) overlap between heat shields.

Attach the extended heat shield to either of the existing heat shields using the screws supplied with the extended heat shield. Refer to vent components diagrams in the back of this manual.

Rest the small leg on the extended heat shield on top of the pipe section to properly space it from the pipe section.

Important Notice: Heat shields may not be field constructed.

38

Heat & Glo • Escape-42DV2052-900 Rev. Y • 11/11

Image 38
Contents Model What to do if you smell gasCongratulations Homeowner Reference InformationTable of Contents User GuideFinishing Appliance SetupTroubleshooting Reference MaterialsLimited Lifetime Warranty Limited Lifetime WarrantyWarranty Conditions Listing and Code Approvals Installation of Carbon Monoxide Detectors Requirements for the Commonwealth of MassachusettsYour Fireplace Gas Fireplace SafetyOperating Instructions User Guide Clear Space Fixed Glass AssemblyWall Controls and Wall Switches Decorative Doors and FrontsLighting Instructions IPI Final inspection byFrequently Asked Questions After Fireplace is LitMaintenance and Service Venting Maintenance Tasks-Qualified Service TechnicianGasket Seal and Glass Assembly Inspection LogsBurner Ignition and Operation IPI Pilot Flame PatternsGetting Started Typical Appliance SystemInspect Appliance and Components Design and Installation ConsiderationsTools and Supplies Needed Framing and Clearances Selecting Appliance LocationConstructing the Appliance Chase ClearancesCombustible Mantel Legs or Wall Projections Mantel and Wall ProjectionsCombustible Mantels Hearth Extension Fireplace sitting on combustible surfaceTermination Locations Vent Termination Minimum ClearancesCovered Alcove Applications Porch, deck or balconyVent Table Key Vent Information and DiagramsApproved Pipe Use of ElbowsH1+ H2 Vent Diagrams Top Vent Horizontal Termination One ElbowTwo Elbows Top Vent Horizontal Termination Three Elbows 12 ft V1 + V2 + H1 = 50 ft .2 m Max Top Vent Vertical Termination Three Elbows Ht MaxWall Penetration Framing Vent Clearances and FramingPipe Clearances to Combustibles Combustible Wall PenetrationInstall the Ceiling Firestop Pipe DVPFlat Ceiling Installation Install Attic Insulation ShieldInstalling the Optional Heat-ZoneGas Kit  Vaulted Ceiling InstallationSecuring and Leveling the Appliance Removing Non-combustible Facing Ma- terial AssemblyAppliance Preparation Installing Non-combustible Facing Material MaterialAssemble Vent Sections Installing Vent PipeAttach Vent to the Firebox Assembly Assemble Pipe SectionsAssemble Slip Sections Secure the Vent SectionsRotate Seams for Disassembly Disassemble Vent SectionsInstall Metal Roof Flashing Assemble and Install Storm CollarInstall Vertical Termination Cap Heat Shield Requirements for Horizontal TerminationInstall Horizontal Termination Cap DVP-HPC1 DVP-HPC2Gas Pressure Gas InformationFuel Conversion Gas ConnectionIntelliFire Ignition System Wiring Wiring RequirementsOptional Accessories Requirements Electrical InformationDetail a Electrical Service and Repair Junction Box Installation Splatter Guard To install the Splatter GuardFinishing Facing Material Noncombustible Facing Diagram Finishing Materials RequirementsAppliance Setup Step Log Set Assembly LOGS-ESCAPE42 Models Escape-42DVInstall the Log Assembly LOG #1 SRV2012-081 Three LOG #2 SRV2012-082 TwoLOG #5 SRV2012-085 LOG #3 SRV2052-083LOG #4 SRV2012-084 LOG #8 SRV2012-088 LOG #6 SRV2052-086LOG #7 SRV2012-087 Final StepAir Shutter Settings Install the MeshAir Shutter Setting IntelliFire Ignition System TroubleshootingSymptom Possible Cause Corrective Action Ues to spark, and main Appliance Dimension Diagram Reference MaterialsVent Components Diagrams DVP-AS2DVP-TRAP1 DVP-TRAP2 DVP-TRAPK1 DVP-TRAPK2 DVP-HPC1 DVP-HPC2 RF6M RF12M 12-1/2 Optional Wire Harness Description Part NumberContact Information

Escape-42DVLP, Escape-42DV specifications

The Heat & Glo LifeStyle Escape-42DV and Escape-42DVLP are innovative direct vent gas fireplaces designed to enhance the ambiance of any living space while providing efficient heating. These models represent the perfect blend of modern technology, aesthetic appeal, and user-friendly features, making them popular choices for homeowners seeking a stylish and functional heating solution.

One of the standout features of the Heat & Glo LifeStyle Escape-42DV is its impressive design. With a large viewing area, the fireplace allows for a mesmerizing display of flames, creating a focal point in any room. The clean, contemporary lines of the unit fit seamlessly into various décor styles, whether modern, traditional, or transitional. Furthermore, the Escape-42DVLP version, designed for those desiring a low-profile option, ensures that homeowners can enjoy the aesthetics of a fireplace without overwhelming the space.

Both models boast advanced technologies that enhance performance and usability. The Direct Vent System allows for efficient combustion by drawing air from outside the home and expelling exhaust gases through a sealed vent. This ensures optimal efficiency and makes them suitable for tight, energy-efficient homes. Additionally, these fireplaces include a Status Light feature that indicates when the fireplace is operating, ensuring peace of mind for users.

The LifeStyle Escape series also excels in customizability. Homeowners can choose from various log sets, decorative media, and tile surrounds, allowing them to tailor their fireplace to match personal styles and preferences. The IntelliFire app provides a convenient way to control the fireplace from a smartphone, featuring options for remote ignition, programmable timers, and flame height adjustments, putting users in complete control of their heating experience.

Safety is paramount, and the Heat & Glo LifeStyle Escape models come equipped with an advanced safety barrier to prevent accidental contact with the hot glass surface, making them family-friendly options. Moreover, their low emissions and high-efficiency ratings contribute to environmentally responsible heating.

In summary, the Heat & Glo LifeStyle Escape-42DV and Escape-42DVLP models combine striking aesthetics, efficient heating technologies, and user-centric features. They offer a modern solution for anyone looking to elevate their home's warmth and sophistication, making them a smart investment for comfort and style.