Heat & Glo LifeStyle EM-485T - 42, EM-415 - 36 Design and Installation Considerations, Draft

Page 15

B. Design and Installation Considerations

Notice: Check building codes prior to installation.

Installation MUST comply with local, regional, state and national codes and regulations.

Consult insurance carrier, local building inspector, fire officials or authorities having jurisdiction over restrictions, installation inspection and permits.

Before installing, determine the following:

Where the fireplace is to be installed.

The vent system configuration to be used.

Gas supply piping.

Electrical wiring.

Framing and finishing details.

Whether optional accessories—devices such as a fan, wall switch or remote control­—are desired.

C. Draft

Draft is the pressure difference needed to vent fireplaces successfully. When a fireplace is drafting successfully, all combustion byproducts are exiting the home through the chimney.

Considerations for successful draft include:

Preventing negative pressure

Location of fireplace and chimney

NoTICE: Hearth & Home Technologies assumes no responsibility for the improper performance of the fireplace system caused by:

Inadequate draft due to environmental conditions

Downdrafts

Tight sealing construction of the structure

Mechanical exhausting devices

Improper location of the chimney

D. Negative Pressure

Warning! Risk of Asphyxiation! Negative pressure can cause spillage of combustion fumes and soot. Fire must draft properly for safe operation.

Negative pressure results from the imbalance of air avail- able for the fireplace to operate properly. It can be stron- gest in lower levels of the house.

Causes include:

Exhaust fans (kitchen, bath, etc.)

Range hoods

Combustion air requirements for furnaces, water heaters and other combustion appliances

Clothes dryers

Location of return-air vents to furnace or air conditioning

Imbalances of the HVAC air handling system

Upper level air leaks such as:

-Recessed lighting

-Attic hatch

-Duct leaks

To minimize the effects of negative air pressure:

Install the outside air kit with the intake facing prevailing winds during the heating season

Ensure adequate outdoor air for all combustion appliances and exhaust equipment

Ensure furnace and air conditioning return vents are not located in the immediate vicinity of the fireplace

Avoid installing the fireplace near doors, walkways or small isolated spaces

Recessed lighting should be a “sealed can” design

Attic hatches weather stripped or sealed

Attic mounted duct work and air handler joints and seams taped or sealed

Basement installations should be avoided

NoTICE: Hearth & Home Technologies Inc. recommends the use of direct vent fireplaces in basements.

Heat & Glo • EM-415, EM-485 • 33056 • Rev AF 7/12

15

Image 15
Contents Fire Risk Wood Burning FireplaceOperation Hot screen/mesh and glass doors will cause burnsListing Label Information/Location GrateNumber Table of Contents Installer GuideUser Guide Warranty Hearth & Home Technologies Inc Warranty Conditions Combustible Materials Listing and Code ApprovalsAppliance Certification Non-Combustible MaterialsOperating Instructions Your FireplaceHot glass will cause burns Firescreen Seasoned WoodStarting a Fire GrateClear Space Glass DoorsVented Gas Log Sets & Gas Log Lighters Optional ComponentsHardwood vs Softwood Wood FuelMaintenance and Service Chimney Inspection/CleaningDisposal of Ashes Frequency As desired Glass CleaningCheck Firebox Refractory Inspect GrateStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedDesign and Installation Considerations DraftNegative Pressure Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededSelect Fireplace Location Fireplace Dimensions .A 1219 mm MinimumConfigurations Framing & ClearancesClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsPlace Protective Metal Hearth Strips Installation of FireplaceThings to Consider Position the FireplaceFt min. from top of uppermost chimney section to air inlet Junction Box Installation Install Outside Air KitPrepare Junction Box Bracket Installation of FanMaintain minimum height of chimney above roof Chimney AssemblyHeight of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsInstall Chimney Air Kit Installing Ceiling FirestopsAssembling Chimney Sections Prepare Attic Insulation Shield Installing Attic Insulation ShieldComplete Installation Install FlashingCut out Hole in Roof Flat Roofs Chimney Termination RequirementsChase should be constructed in the manner of all Chase InstallationsConstruct the Chase Gas line holes and other openings should be caulked withInstall Chase Top Install Fireplace & ChimneyST375 Square Termination Cap Install Termination CapTCT375 Terra Cotta Cap TS345/TS345P Square Termination CapShrouds Radiation ShieldField Constructed Shrouds Mailbox Style Shroud radiation shield required Finishing Hearth Extension= 1/k x inches of thickness Non-combustible Facing Finishing MaterialGrid represents 1 in. scale Combustible MantelWood Burning Inserts AccessoriesInstall Fan Gas Log/Lighter ProvisionReference Materials Catalog # Description Fireplace Components1321 mm 406 mm Catalog # Chimney Components305 mm 24-5/8 625 mm 787 mm Effective Outside Height Diameter 10-1/2 121 mm 267 mm10-1/2 267 mm 305 mm 27-3/8 24-5/8 695 mm 625 mmDTO134 a 10-7/8 276 mm At Depot Service PartsIn. Starter Section Assembly 22069B Top Standoff Stocked28393 Traditional Brick Hearth Refractory Traditional Brick Back Refractory29245 29992 Traditional Brick Side RefractoryEM-485T Traditional Refractory Do not Discard this Manual

EM-485T - 42, EM-415 - 36 specifications

Heat & Glo has established itself as a leader in innovative fireplace solutions, and the LifeStyle series, particularly the EM-415 and EM-485T models, showcases the brand's commitment to quality, efficiency, and design flexibility. These gas fireplaces are designed to seamlessly blend into any living space, providing not just warmth but also a stylish focal point.

The EM-415, with its 36-inch firebox, and the EM-485T, featuring a generous 42-inch firebox, deliver a stunning visual experience. Both models boast a contemporary design that enhances the aesthetics of modern homes. The clean, linear appearance is complemented by a large viewing area, allowing for an unobstructed view of the flames.

In terms of technology, Heat & Glo incorporates advanced features such as Intellifireā„¢ Ignition System, which allows for reliable and safe start-up while ensuring energy efficiency. This system also includes the option for remote control operation, providing added convenience for users. The fireplaces can be easily adjusted to suit individual comfort levels, with variable flame settings that allow for customizable heat output.

Additionally, both models utilize the latest in heat management technology. The Heat & Glo LifeStyle series is designed with excellent insulation, promoting better heat retention and minimizing heat loss. This not only enhances the efficiency of the fireplace but also contributes to overall energy savings.

Safety is paramount in the design of the EM-415 and EM-485T. They are equipped with standard safety features such as an automatic shut-off system, ensuring peace of mind while the fireplace is in use.

Moreover, the versatility of these models is highlighted by their ability to be installed in various settings, including walls and corners. The option for different media, such as glass or stone, allows homeowners to personalize their fireplace, making it a perfect fit for any decor style.

Overall, the Heat & Glo LifeStyle EM-415 and EM-485T gas fireplaces represent a fusion of aesthetics, technology, and safety, making them an ideal choice for anyone looking to enhance the comfort and style of their home. With their range of features and design options, these models are sure to create a warm and inviting atmosphere for years to come.