F. Installing Attic Insulation Shield

Warning! Risk of Fire! You MUST install an attic insu- lation shield when there is any possibility of insulation or other combustible material coming into contact with the chimney.

Do NOT pack insulation between the chimney and the attic insulation shield.

Failure to keep insulation and other materials away from chimney pipe could cause fire.

Do NOT offset chimney inside insulation shield.

Installation of a ceiling firestop is required

Refer to Figures 8.6 - 8.8.

Roll the shield (around the chimney if already installed) until you have a 3 in. (76 mm) overlap and the three holes on each side match up (large holes on top).

Insert three screws into the matching holes to form a tube.

Bend three tabs on the bottom of the tube inward to 90° to maintain chimney air space as shown in Figure 8.6.

Rest the insulation shield on the ceiling firestop below.

Bend the three short tabs at the top of the shield inward to 90° to maintain the 2 in. (51 mm) air space from the chimney.

Bend the remaining top tabs to just meet the pipe.

If you wish to make a custom shield or barrier, follow these guidelines:

Metal is preferred, although any material stiff enough to hold back the insulation can be used.

Warning! Risk of Fire! Use of cardboard or other materials that can deflect under humidity or other envi- ronmental conditions is not recommended.

The shield or barrier must be tall enough to extend above the insulation and prevent blown-in insulation from spilling into the cavity.

Maintain specified air spaces around chimney.

Check instructions and local codes for further details.

 

 

 

 

Bend remaining tabs

 

 

 

 

to rest against pipe to

Bend

 

inward

prevent insulation

90°

 

from falling in.

 

 

 

 

 

Insert three

 

 

 

 

screws

3 in. (76 mm) overlap

Figure 8.6 Prepare Attic Insulation Shield

 

 

Tabs bent in to

 

Pipe

rest against pipe

 

 

 

 

Attic Insulation Shield

 

 

14-1/2 in. (368 mm)

 

6 Tabs bent

diameter

 

in 90°

Ceiling Firestop

 

 

Insulation

Pipe

Insulation

10-1/2 in.

(267 mm)

Figure 8.7 Install Attic Insulation Shield (firestop above ceiling)

 

 

Tabs bent in to

 

 

rest against pipe

 

Pipe

 

 

 

Attic Insulation Shield

 

 

14-1/2 in. (368 mm)

 

 

diameter

 

6 Tabs bent

 

 

in 90°

 

Insulation

 

Insulation

10-1/2 in.

Pipe

Ceiling Firestop

(267 mm)

 

 

Figure 8.8 Install Attic Insulation Shield (firestop below ceiling)

Heat & Glo • EM-415, EM-485 • 33056 • Rev AF 7/12

29

Image 29
Contents Operation Wood Burning FireplaceHot screen/mesh and glass doors will cause burns Fire RiskNumber Listing Label Information/LocationGrate User Guide Table of ContentsInstaller Guide Warranty Hearth & Home Technologies Inc Warranty Conditions Appliance Certification Listing and Code ApprovalsNon-Combustible Materials Combustible MaterialsHot glass will cause burns Operating InstructionsYour Fireplace Starting a Fire Seasoned WoodGrate FirescreenVented Gas Log Sets & Gas Log Lighters Glass DoorsOptional Components Clear SpaceHardwood vs Softwood Wood FuelDisposal of Ashes Maintenance and ServiceChimney Inspection/Cleaning Check Firebox Refractory Glass CleaningInspect Grate Frequency As desiredStart Fire Problems Possible Cause Solution Troubleshooting GuideTypical Fireplace System Getting StartedNegative Pressure Design and Installation ConsiderationsDraft Frequently open doors Central heat outlets or returns Locating Fireplace & ChimneyInspect Fireplace and Components Tools and Supplies NeededConfigurations Fireplace Dimensions .A 1219 mm MinimumFraming & Clearances Select Fireplace LocationClearances to Combustible Materials ClearancesFrame the Fireplace Sidewalls/SurroundsThings to Consider Installation of FireplacePosition the Fireplace Place Protective Metal Hearth StripsFt min. from top of uppermost chimney section to air inlet Junction Box Installation Install Outside Air KitPrepare Junction Box Bracket Installation of FanMaintain minimum height of chimney above roof Chimney AssemblyHeight of Chimney Components Chimney RequirementsExample Using Offsets/ReturnsAssembling Chimney Sections Install Chimney Air KitInstalling Ceiling Firestops Prepare Attic Insulation Shield Installing Attic Insulation ShieldCut out Hole in Roof Complete InstallationInstall Flashing Flat Roofs Chimney Termination RequirementsConstruct the Chase Chase InstallationsGas line holes and other openings should be caulked with Chase should be constructed in the manner of allInstall Chase Top Install Fireplace & ChimneyST375 Square Termination Cap Install Termination CapTCT375 Terra Cotta Cap TS345/TS345P Square Termination CapField Constructed Shrouds ShroudsRadiation Shield Mailbox Style Shroud radiation shield required = 1/k x inches of thickness FinishingHearth Extension Non-combustible Facing Finishing MaterialGrid represents 1 in. scale Combustible MantelInstall Fan AccessoriesGas Log/Lighter Provision Wood Burning InsertsReference Materials Catalog # Description Fireplace Components1321 mm 406 mm Catalog # Chimney Components10-1/2 267 mm Effective Outside Height Diameter 10-1/2 121 mm 267 mm305 mm 27-3/8 24-5/8 695 mm 625 mm 305 mm 24-5/8 625 mm 787 mmDTO134 a 10-7/8 276 mm In. Starter Section Assembly 22069B Top Standoff Service PartsStocked At Depot29245 Traditional Brick Back Refractory29992 Traditional Brick Side Refractory 28393 Traditional Brick Hearth RefractoryEM-485T Traditional Refractory Do not Discard this Manual

EM-485T - 42, EM-415 - 36 specifications

Heat & Glo has established itself as a leader in innovative fireplace solutions, and the LifeStyle series, particularly the EM-415 and EM-485T models, showcases the brand's commitment to quality, efficiency, and design flexibility. These gas fireplaces are designed to seamlessly blend into any living space, providing not just warmth but also a stylish focal point.

The EM-415, with its 36-inch firebox, and the EM-485T, featuring a generous 42-inch firebox, deliver a stunning visual experience. Both models boast a contemporary design that enhances the aesthetics of modern homes. The clean, linear appearance is complemented by a large viewing area, allowing for an unobstructed view of the flames.

In terms of technology, Heat & Glo incorporates advanced features such as Intellifireā„¢ Ignition System, which allows for reliable and safe start-up while ensuring energy efficiency. This system also includes the option for remote control operation, providing added convenience for users. The fireplaces can be easily adjusted to suit individual comfort levels, with variable flame settings that allow for customizable heat output.

Additionally, both models utilize the latest in heat management technology. The Heat & Glo LifeStyle series is designed with excellent insulation, promoting better heat retention and minimizing heat loss. This not only enhances the efficiency of the fireplace but also contributes to overall energy savings.

Safety is paramount in the design of the EM-415 and EM-485T. They are equipped with standard safety features such as an automatic shut-off system, ensuring peace of mind while the fireplace is in use.

Moreover, the versatility of these models is highlighted by their ability to be installed in various settings, including walls and corners. The option for different media, such as glass or stone, allows homeowners to personalize their fireplace, making it a perfect fit for any decor style.

Overall, the Heat & Glo LifeStyle EM-415 and EM-485T gas fireplaces represent a fusion of aesthetics, technology, and safety, making them an ideal choice for anyone looking to enhance the comfort and style of their home. With their range of features and design options, these models are sure to create a warm and inviting atmosphere for years to come.