White Rodgers 1F90W-71 manual Total Keypad Lockout, Limited Temperature Range

Page 18

Total Keypad Lockout

ON

Group A

Option

Switches

1 2

Switch #1 ON

Switch #2 OFF

To enable total keypad lockout, move Group A option switch #1 to ON (see figure above). To disable total keypad lockout, move op- tion switch #1 to OFF.

LIMITED TEMPERATURE RANGE — When Group A option switch #1 is in the OFF position and option switch #2 is in the ON position, the heating and cooling tem-

peratures may be changed using the

and buttons, but the temperatures may not be set to exceed any programmed maximum heating or minimum cooling tem-

18

peratures. To enable limited temperature range, move Group A switch #1 to the OFF position and switch #2 to the ON position (see figure below). To disable limited tem- perature range, move switch #2 to the OFF position (see TOTAL KEYPAD LOCKOUT to determine the correct position of option switch #1).

NOTE

Programming should be completed and batter- ies should be installed before changing Group A option switches #1 or #2.

Limited Temperature Range

ON

Group A

Option

Switches

1 2

Switch #1 OFF

Switch #2 ON

Image 18
Contents 1F90W-71 About Your New Thermostat Questions and Answers Your NEW Thermostats Programming YourOperating Your Thermostat Your NEW THERMOSTAT’S Features Operating Your Thermostat Parts of the Thermostat Back of The Thermostat BodyBack of Thermostat Body Display System Time SET Thermostat Buttons Used withButtons to 11 12 Operating Features EMR on TWO Hour Temperature Over Automatic ChangeoverAdvance Program KEY Press To change the thermostat to the nextConvertibility Press Time Use Adjust anticipation. PressAt the same time again To returnHEAT-OFF-COOL-AUTO Limited Temperature Range Total Keypad LockoutProgramming Your Thermostat Your Home Period Time Temp Entering Your Program Heating/Cooling Schedule Plan Sample Until Set Current Time and DayPress and hold either Enter Heating ProgramPrgm to resume program operation Enter Cooling Program Check Your Programming How can I permanently change a part of my program? Ming Your ThermostatProgramming Your Thermostat Why can’t I program the thermostat in the Auto mode? Erating Your ThermostatGramming Your Thermostat Thermostat immediately, press Display is flashing BATTERY. What does this mean? Programming Your THERMO- Stat Why is the system turning on and off so frequently seldom?See Operating Your THERMO- Stat Ating Your ThermostatAny time you wish to turn your system off Simply press Is displayed, put the thermostat back on Part No -5088A