MHC36 AND MHR36 INSTALLATION INSTRUCTIONS
A. LISTINGS AND CODE APPROVALS
This fireplace system has been tested and listed in accordance with UL 127 standards, and has been listed by Underwriters Laboratories Inc. for installation and operation in the United States.
This fireplace has been tested and listed for use with the optional components listed on page 5. These optional components may be purchased separately and installed at a later date. However, installation of an outside air kit will require significant reconstruction, and should be installed at the time of the initial fireplace installation.
Check with your local building code agency prior to installing this fireplace to ensure compliance with local codes, including the need for permits and
Heatilator® is a registered trademark of Hearth & Home Technologies Inc.
WARNING!
This fireplace and its components are designed to be installed and operated as a system. Any alteration to or substitution for items in this system, unless allowed by these installation instructions, will void the Underwrit- ers Laboratories listing and may void the product warranty. It may also create a hazardous installation. Read through these instructions thoroughly before starting your installation and follow them carefully throughout your project.
B. DESCRIPTION OF THE FIREPLACE SYSTEM
1.The Heatilator fireplace system consists of the following:
a.Fireplace/Integral Grate/Outside Combustion Air System
b.Refractory
c.Chimney Termination Cap
d.Chimney System
e.Hearth Extension
The CP311 Convenience Pack has been designed for the convenience of customers wishing to install a chimney system at the 11 ft minimum straight height. The CP313 Convenience Pack has been designed for those wishing to install a chimney system at the 13 ft minimum straight height.
The following combination of listed parts are included in both the CP311 and CP313 Convenience Packs:
CP311 & CP313 Convenience Packs
Cat. # | Qty. | Description: |
|
|
|
SL324 | 2 | Chimney Section - 24 in. long |
|
|
|
SL336 | 2 | Chimney Section - 36 in. long |
|
|
|
MH842 | 1 | Roof Thimble and Flashing |
|
|
|
TR344 | 1 | Round Termination Cap |
|
|
|
2.Optional Components Include:
a.Glass Doors
b.Fan Kit (MHC36 only)
Note: Illustrations used throughout these instructions reflect “typical installations” and are for design purposes only. Actual installation may vary slightly due to individual design preferences. However, minimum and maximum clearances must be maintained at all times.
The illustrations and diagrams used throughout these installation instructions are not drawn to scale.
Figure 1 - Typical Fireplace System
4 | 31072 Rev G | 08/04 |