GN National Electric GP)-1, GN, CP LOG SET Installation Instructions, Log Installation, All Logs

Page 16

LOG SET INSTALLATION INSTRUCTIONS

Log Installation

The gas log set (front left log, front right log, center log and rear log) is pre-set and installed in the factory. Only the top left log and top right log are packaged separately inside the firebox for instal- lation by the installer.

1.To access the log set parcel, lift off top panel.

2.Pivot left and right panels open.

3.Unlatch main door latches located on right and left hand side of the heater, remove door.

4.Carefully remove top left log and top right log from firebox and remove cardboard protection from center log and middle log and all packaging materials.

Note: Positions of front left log, front right log, center log, and rear log have been preset at the factory and their loca- tions should not be changed. Check that logs have not been damaged in transit.

5.Carefully remove wrapping from top left log and top right log.

Note: Before you begin: Do not handle these logs with your bare hands! Always wear gloves to prevent skin irritation. After handling logs, wash your hands gently with soap and wa- ter.

All Logs

The positioning of the logs is critical to the safe and clean opera- tion of this heater. Sooting and other problems may result if the logs are not properly and firmly positioned in the appliance.

6.Prior to positioning of top left log and top right log, inspect front burner and rear burner for particles or dust accumula- tion on top of burners. If any particles or dust is visible on top of front or rear burners, remove particles before placing top left log and top right log into position.

7.Position top left log into locating pin on rear log and rest on center log. See Figure 12.

8.Position top right log into locating slot on rear log. See Fig- ure 12.

9.After top left log and top right log have been placed in posi- tion and safety check has been carried out, install door and latch securely with latches located on right and left side of heater.

TOP LEFT LOG

REAR LOG

TOP RIGHT LOG

CENTER LOG

FRONT RIGHT LOG

FRONT LEFT LOG

Figure 12

Page 16

22618-4-1106

Image 16
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorRequirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsInstalling a New Main Gas Cock Pressure Testing of the Gas Supply SystemGAS Supply Recommended Gas Pipe DiameterIntroduction Specifications AccessoriesHeater Installation for Direct Vent Installation on Rugs and TileClearances for Direct Vent Locating Wall OpeningHeater Installation for Single Flue Clearances for Single FlueHeater with Pedestal and Single Flue Adaptor Specifications Heater without PedestalFireplace Insert with Mantel surround with slim top panel Flue Outlet Electric Cord 8 BSP Connection Inside SurroundFireplace Insert with Mantel Surround with short top panel Clearance to Combustibles Freestanding UnitsLog Installation LOG SET Installation InstructionsAll Logs LOG SET Diagram a Installation Instructions General Safety Information Vent Examples for Single Flue Vent Examples for Single Flue Single Flue Vertical Vent RunFlex Vent Tubing Venting for Existing Fireplace Installation Determining Minimum Vent Height Above the RoofDirect Vent Installation Instructions Direct Vent System Building Exterior ViewHorizontal Venting Maximum Horizontal Venting 47 1/2 1.2mMinimum Exterior Grade Dimension Unit Without Pedestal Minimum Exterior Grade Dimension Unit With PedestalDirect Vent Installation Instructions GAS Connection Installation Instructions GAS Connection Line SupplyOperating Instructions Checklist Lighting Instructions For Your Safety Read Before Lighting FAN Operation GAS Conversion Instructions Conversion Instructions from LP Propane GAS to Natural GASConversion Instructions from Natural GAS to LP Propane GAS Automatic Humidifier Operation Optional Remote Control Thermostat Thermostat Display ModeWiring Wiring DiagramMaintenance Over Temperature Cut OutGeneral Information Paint Curing First FiringFront door removal drawing Glass Cleaning Glass Assembly ReplacementMain Burner Drawing Cleaning Main Burner General Glass InformationUnit Operating Faults Resetting the HeaterMain Convection FAN LOG PlacementHeat Exchanger Surround Installation Instructions Parts ListPedestal Installation Instructions Optional Pedestal Assembly InstallationParts List Index Part Number DescriptionGAS Line Front Parts View 7368 Warranty Terms Purchase Date Dealer Name/PhoneHOW to Order Repair Parts Service Notes