GN National Electric BP)-1, PV-28SV50, PV-28SV55, GN, GP)-1, CP Operating Instructions Checklist

Page 27

OPERATING INSTRUCTIONS CHECKLIST

BEFORE OPERATING THIS APPLIANCE, CAREFULLY PROCEED THROUGH THE FOLLOWING CHECKLIST

1.Read and understand these instructions before installing or operating this appliance.

2.This appliance is should be installed and repaired by a fully qualified service person who must be familiar with the instal- lation of the Mantis Power-Vent High-Efficiency Fireplace.

3.Installers who are not familiar with the installation of this ap- pliance should contact Empire Comfort Systems, Inc. prior to installing the appliance to avoid creating hazardous operating conditions.

4.Check and inspect the appliance for gas leaks. In the event of gas leaks, cut off the gas supply to the heater immediately and call your gas supplier or installer.

5.Check and verify that all flue venting combustion air intakes and flue outlets are unobstructed.

6.Refer to pages 19 to 22 for Single Flue pipe and pages 23 to 25 for Co-axial Flue installations. Check that correct flue pipe and cap has been fitted in line with the manufacturer’s specifications as illustrated in this manual pages 11 to 25.

7.Do not use alternative Flue or cap on installation other than that specified in this manual - otherwise heater will malfunc- tion and cause hazardous operating conditions and will void the manufacturer’s warranty.

8.Check and verify that flue pipe connection to the appliance when using single 1 1/2” flue pipe installation is correctly installed and secured in line with instruction in this manual, Pages 19 to 22.

9.Prior to operating the appliance, check for dust or debris on the burners. Refer to Page 37, Figure 47.

10.Check and verify that logs are place correctly as per instruc- tions on Pages 16 to 17 of this manual. If logs are incorrectly positioned, it can create a hazardous situation, and in most instances, the heater will not operate correctly.

11.Do not light heater without logs installed, as heater will not operate properly.

12.Check and verify prior to starting the appliance, that all panels are secured in place and that the main door has been locked in position.

13.After verifying and checking all the above points, proceed to lighting instructions. Refer to pages 28 to 29.

22618-4-1106

Page 27

Image 27
Contents Installation Instructions Table of Contents This is a Heating Appliance Important Safety InformationLP-GAS Warning Odor Safety Information for Users of LP-GASVent Directly BELOW. Keep Clear of ALL Obstructions Requirements for MassachusettsRecommended Gas Pipe Diameter Installing a New Main Gas CockPressure Testing of the Gas Supply System GAS SupplyIntroduction Accessories SpecificationsLocating Wall Opening Heater Installation for Direct VentInstallation on Rugs and Tile Clearances for Direct VentClearances for Single Flue Heater Installation for Single FlueHeater with Pedestal and Single Flue Adaptor Heater without Pedestal SpecificationsFlue Outlet Electric Cord 8 BSP Connection Inside Surround Fireplace Insert with Mantel surround with slim top panelFireplace Insert with Mantel Surround with short top panel Freestanding Units Clearance to CombustiblesLOG SET Installation Instructions Log InstallationAll Logs LOG SET Diagram a Installation Instructions General Safety Information Vent Examples for Single Flue Single Flue Vertical Vent Run Vent Examples for Single FlueFlex Vent Tubing Determining Minimum Vent Height Above the Roof Venting for Existing Fireplace InstallationMaximum Horizontal Venting 47 1/2 1.2m Direct Vent Installation InstructionsDirect Vent System Building Exterior View Horizontal VentingMinimum Exterior Grade Dimension Unit With Pedestal Minimum Exterior Grade Dimension Unit Without PedestalDirect Vent Installation Instructions GAS Connection Line Supply GAS Connection Installation InstructionsOperating Instructions Checklist Lighting Instructions For Your Safety Read Before Lighting FAN Operation Conversion Instructions from LP Propane GAS to Natural GAS GAS Conversion InstructionsConversion Instructions from Natural GAS to LP Propane GAS Automatic Humidifier Operation Thermostat Display Mode Optional Remote Control ThermostatWiring Diagram WiringPaint Curing First Firing MaintenanceOver Temperature Cut Out General InformationGeneral Glass Information Front door removal drawing Glass CleaningGlass Assembly Replacement Main Burner Drawing Cleaning Main BurnerResetting the Heater Unit Operating FaultsLOG Placement Main Convection FANHeat Exchanger Parts List Surround Installation InstructionsOptional Pedestal Assembly Installation Pedestal Installation InstructionsIndex Part Number Description Parts ListGAS Line Front Parts View 7368 Purchase Date Dealer Name/Phone Warranty TermsService Notes HOW to Order Repair Parts