GN National Electric GP)-1, PV-28SV50 Optional Remote Control Thermostat, Thermostat Display Mode

Page 34

OPTIONAL REMOTE CONTROL THERMOSTAT

An optional programmable Remote Control Thermostat can be fit- ted to the heater at the factory when ordered or even after the heat- er has been installed. See your Mantis dealer for correct type.

Installation: The Remote Control can be installed by the owner of the heater if required. The Remote Control is a battery operated device, which requires a small amount of low voltage wiring. A wiring loom package is supplied by Empire Comfort Systems, Inc. which simply attaches onto the junction box. See Figure 35.

In basic terms the red button acts as a Remote Control override switch for the front burner only. Also the Remote can switch the heater on and off in the high setting, medium setting or low set- ting.

Note: When the heater or the Remote Control is not being used for long periods the burner switches should be in the off posi- tion, also in summer the heater should be turned off at the power point.

Remove blue jumper wire from junction block and save for fur- ture use. From the remote control receiver, cut and strip one black wire 1/4” terminal from wire. Attach the stripped black wire to the blue wire connector from the transformer on the junction box. From the remote control receiver, attach the Y wiring lead to the 1/4” terminal on the black wire. Attach the one white wire to the red wire connection from “T1” on the junction block. Attach the other white wire from the remote control receiver to the black wire connection from “T2” on the junction block.

THERMOSTAT

DISPLAY MODE

OPTIONAL

REMOTE

BLACK

 

CONTROL /

WHITE

 

THERMOSTAT

WHITE

 

 

JUNCTION

 

BLOCK

BLUE

TO “T2”

TO

BLUE TRANSFORMER

RED TO “T1”

 

BLACK

 

TO “T2”

 

 

WHITE

 

TO “T1”

BUTTON

Figure 40

Figure 43

FRONT

REAR

BURNER

BURNER

SWITCH

SWITCH

Figure 41

Figure 42

Economy Display Mode (Red Button Operation): The red but- ton above the two burner switches is called the economy display mode and will only function when a Remote Control Thermostat has been installed in the heater. The most common way this button is used to have the Remote Control set on Thermo mode with a desired temperature set for the heater to turn on and off, which is dependant on the ambient temperature, location and the area the appliance is positioned in. When using a Remote Control Ther- mostat both burner switches need to be in the on position. When the red button is pressed with both burner switches on, the front burner only will ignite or if already alight, it will now remain on regardless of what function or temperature is set on the Remote Control.

In this situation only the back burner will turn on and off accord- ing to the setting on the Remote Control. By running the heater this way you will use less gas and still have the aesthetic effect of the front burner. However, if the appliance is in a small area, this setting may get to warm for you. To change the setting, press the red button so that it is not illuminated and the heater will revert back to its normal operation.

Page 34

22618-4-1106

Image 34
Contents Installation Instructions Table of Contents Important Safety Information This is a Heating ApplianceSafety Information for Users of LP-GAS LP-GAS Warning OdorRequirements for Massachusetts Vent Directly BELOW. Keep Clear of ALL ObstructionsGAS Supply Installing a New Main Gas CockPressure Testing of the Gas Supply System Recommended Gas Pipe DiameterIntroduction Specifications AccessoriesClearances for Direct Vent Heater Installation for Direct VentInstallation on Rugs and Tile Locating Wall OpeningHeater Installation for Single Flue Clearances for Single FlueHeater with Pedestal and Single Flue Adaptor Specifications Heater without PedestalFireplace Insert with Mantel surround with slim top panel Flue Outlet Electric Cord 8 BSP Connection Inside SurroundFireplace Insert with Mantel Surround with short top panel Clearance to Combustibles Freestanding UnitsLog Installation LOG SET Installation InstructionsAll Logs LOG SET Diagram a Installation Instructions General Safety Information Vent Examples for Single Flue Vent Examples for Single Flue Single Flue Vertical Vent RunFlex Vent Tubing Venting for Existing Fireplace Installation Determining Minimum Vent Height Above the RoofHorizontal Venting Direct Vent Installation InstructionsDirect Vent System Building Exterior View Maximum Horizontal Venting 47 1/2 1.2mMinimum Exterior Grade Dimension Unit Without Pedestal Minimum Exterior Grade Dimension Unit With PedestalDirect Vent Installation Instructions GAS Connection Installation Instructions GAS Connection Line SupplyOperating Instructions Checklist Lighting Instructions For Your Safety Read Before Lighting FAN Operation GAS Conversion Instructions Conversion Instructions from LP Propane GAS to Natural GASConversion Instructions from Natural GAS to LP Propane GAS Automatic Humidifier Operation Optional Remote Control Thermostat Thermostat Display ModeWiring Wiring DiagramGeneral Information MaintenanceOver Temperature Cut Out Paint Curing First FiringMain Burner Drawing Cleaning Main Burner Front door removal drawing Glass CleaningGlass Assembly Replacement General Glass InformationUnit Operating Faults Resetting the HeaterMain Convection FAN LOG PlacementHeat Exchanger Surround Installation Instructions Parts ListPedestal Installation Instructions Optional Pedestal Assembly InstallationParts List Index Part Number DescriptionGAS Line Front Parts View 7368 Warranty Terms Purchase Date Dealer Name/PhoneHOW to Order Repair Parts Service Notes