TROUBLESHOOTING
Continued
WARNING: If you smell gas
•Shut off gas supply.
•Do not try to light any appliance.
•Do not touch any electrical switch; do not use any phone in your building.
•Immediately call your gas supplier from a neighbor’s phone. Fol- low the gas supplier’s instructions.
•If you cannot reach your gas supplier, call the fire department.
OBSERVED PROBLEM | POSSIBLE CAUSE | REMEDY | |||
|
|
|
|
|
|
Pilot will not stay lit | 1. | Loose wiring on ignitor wire | 1. | Check wiring connection. | |
|
| to ignition module and/or poor |
| Refer to wiring diagram (see | |
|
| ground to ignition module |
| Wiring Diagram, page 27) | |
|
|
|
| and/or check ground wire to | |
| 2. | Pilot flame too low to sense | 2. | ignition module | |
| Clean and adjust pilot burner | ||||
|
|
|
| and check gas supply and inlet | |
|
|
|
| pressure to unit. Note: Have a | |
|
|
|
| qualified technician replace pilot | |
|
|
|
| assembly if broken or corroded | |
|
|
|
|
|
|
No gas to burner, although wall | 1. | Wall switch wires defective or | 1. | Check electrical connections | |
switch and valve are set to the |
| too long |
|
|
|
ON position |
|
|
|
|
|
Frequent pilot outage | 1. | Pilot flame may be too low, | 1. | Clean and adjust pilot flame for | |
|
| causing safety pilot to “drop |
| maximum flame impingement | |
| 2. | out” | 2. | on thermopile | |
| Improper venting or excessive | Have the vent system inspect- | |||
|
| blockage |
| ed, including the termination | |
|
|
|
| cap. Remove any restriction or | |
|
|
|
| obstruction | |
|
|
|
|
|
|
Fireplace produces a clicking/tick- | 1. | Metal expanding while heating | 1. | This is normal with most fire- | |
ing noise just after burner is lit |
| or contracting while cooling |
| places. If noise is excessive, | |
or shut off |
|
|
| contact qualified service person | |
|
|
|
|
|
|
Slight smoke or odor during initial | 1. | Residues from manufacturing | 1. | Problem will stop after a few | |
operation |
| processes and logs curing |
| hours of operation | |
|
|
|
| ||
Gas odor even when control knob | 1. | Gas leak. See Warning 1. Locate and correct all leaks | |||
is in OFF position |
| statement at top of page |
| (see Checking Gas Connec- | |
| 2. | Control valve defective | 2. | tions, page 21) | |
| Replace control valve | ||||
|
|
|
|
|
|
Gas odor during combustion | 1. | Foreign matter between con- | 1. | Take apart gas tubing and | |
| 2. | trol valve and burner | 2. | remove foreign matter | |
| Gas leak. See Warning | Locate and correct all leaks | |||
|
| statement at top of page |
| (see Connecting Fireplace to | |
|
|
|
| Gas Supply, page 21) |
32 | www.desatech.com |