Desa (V)T32EN SERIES, (V)T32EP SERIES installation manual Parts List

Page 35

PARTS LIST

This list contains replaceable parts used in your fireplace. When ordering parts, follow the instructions listed under Replacement Parts on page 38 of this manual.

PART NUMBER

 

(V)T32EN

(V)T32ENR

 

 

(V)T32EP

(V)T32EPR

 

KEY

(V)T32ENB

(V)T32ENRB

 

NO.

(V)T32EPB

(V)T32EPRB

DESCRIPTION

1

**

**

Firebox Assembly

2

**

**

Face Weldment

3

108892-01

108892-01

Door Assembly (T Models Only)

 

108892-02

108892-02

Door Assembly (VT Models Only)

4

108903-01

109155-01

Top Louver Assembly

5

108903-02

109155-02

Bottom Louver Assembly

6

108895-01

108895-01

Fireplace Top

7

**

**

Fireplace Top Insulation

8

**

**

Fireplace Surround

9

108885-03

108885-03

Burner Assembly (Natural Gas)

 

108885-04

108885-04

Burner Assembly (Propane/LP Gas) (See

 

 

 

 

pages 34 & 35)

10

108890-01

108890-01

Burner Base Gasket

11

109082-03

109082-03

Heat Shield

12

108897-01

108897-01

Rear Refractory Brick Panel (B Models Only)

13

108901-01

108901-01

Right Refractory Brick Panel (B Models Only)

14

108901-02

108901-02

Left Refractory Brick Panel (B Models Only)

15

11418

11418

 

Push-On Nut

16

108440-01

108440-01

Screen

17

109479-01

109479-01

Screen Rod

18

14123

14123

 

Strain Relief

19

21171

21171

 

Gas Knock-Out Cover

20

24353

24353

 

Handy Box Assembly

21

24460

24460

 

Gas Conduit Assembly

22

109222-01

109222-01

Log Set

22-1 109403-01

109403-01

Front Log (Log 1)

22-2 109404-01

109404-01

Rear Log (Log 2)

22-3 109407-01

109407-01

Base Log (Log 3)

22-4 109406-01

109406-01

Crossover Log (Log 4)

22-5 109405-01

109405-01

Left Top Log (Log 5)

22-6

109408-01

109408-01

Right Top Log (Log 6)

 

 

 

PARTS AVAILABLE - NOT SHOWN

 

 

 

QTY.

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

1

2

2

1

1

2

1

1

1

1

1

1

1

1

1

25487

25487

27253

27253

55240

55240

*** Not a field replaceable part.

Lava Rock/Bag Assy

Notice Label

Vent Label

1

1

1

111987-01D

www.desatech.com

35

Image 35
Contents What to do if YOU Smell GAS Safety Information Table of ContentsSafety Information High traffic areas Product FeaturesLocal Codes Product IdentificationProper clearances must be maintained Pre-Installation PreparationLocation and space requirements Venting clearances ClearancesFraming and finishing Front Top of Standoffs Vent See ventingCombustible Noncombustible Location of Termination CapInstallation Precautions Venting Installation InstructionsInstallation Planning Installing Horizontal Vent Cap Noncombustible Exterior Ground Floor Installation Recommended Applications Corner ground floor installation Snorkel Termination InstallationHorizontal System Installation Using TWO 90 Elbows Connect a section of pipe and extend up through the hole Installation for vertical terminationFlat Ceiling Installation Twist-lock the vent cap onto the last section of vent pipe Installing FirestopVertical Venting High Altitude InstallationNumber Description Parts list for venting kits and componentsCheck GAS Type Fireplace InstallationInstalling optional blower accessories Model BK InstallationPlug in blower power cord to duplex outlet Model BKT InstallationInstallation Items Needed Installing Gas Piping to Fireplace LocationBlower Wiring Diagram Checking GAS Connections Connecting Fireplace to GAS SupplyTest Pressures Equal To or Less Than Psig 3.5 kPa Pressure Testing Fireplace Gas ConnectionsRemoving Glass Door Cleaning Glass DoorRemoving/Replacing Glass Door Removing Louver PanelsClose top and bottom louvers Installing Optional Brick liner Model BL32DInstalling logs, lava rock and glowing embers Installing Log No Open lower louver panel of firebox Optional Remote control Installation model WRCWall Switch Installation Line Wiring DiagramPilot Gas Lighting Instructions For your safety Read before lightingOperating Fireplace Burner Flame Pattern Inspecting BurnersTo Turn OFF GAS To Appliance Optional Remote OperationLogs Cleaning MaintenanceGlass Door Pilot and burnersVenting system Cleaning and MaintenanceTroubleshooting Observed Problem Possible Cause RemedyGas leak. See Warning Glass soots Flame impingement on logs Tery power is low RemoteImproper log placement Clean out air holes at burnerIllustrated Parts Breakdown Parts List 109 11102 Specifications Replacement PartsService Hints Technical ServiceAccessories Limited Warranty DIRECT-VENT Fireplace Warranty InformationKeep this Warranty